Kemper MaxiFil 65 650 Operating Manual page 65

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 40
Item
Description
1
Filter element
2
Gasket ring
3
Sealing cap
Changing the filter element:
1. Switch the product off at the device switch.
2. Prevent unintentional restarting by disconnecting the mains plug.
3. Remove the new filter element from the box and remove the sealing
cap (item 3). Ensure the sealing ring (item 2) is not damaged in the
process.
4. Gently lift the saturated filter element (item 1) and carefully pull it out of
the product.
5. Seal the saturated filter element with the sealing cap (item 3) of the new
filter element to make it airtight. Then dispose of the saturated filter
element in accordance with current regulations.
6. Push the new filter element back into the product mounting (item 5) in
reverse order. Ensure that the sealing ring (item 2) does not rub against
the sealing surface (item 6) of the extraction arm holder (item 4),
otherwise it may be deformed or destroyed.
1502762-02
Fig. 13: Changing filters
Item
4
5
6
Tab. 14: Changing filters
- 65 -
Description
Extraction arm holder
Mounting frame
Sealing surface