Download Print this page

Bosch DIVAR AN 3000 Release Notes page 8

Hide thumbs Also See for DIVAR AN 3000:

Advertisement

Security Systems
Product
DIVAR AN 3000/5000
Important behavior / known issues:
-
No Daylight Saving Time (DST) support in first release of DIVAR3000/5000 on local unit
and BVC. Our advice is to select 'Display local time of device' in BVC user settings when
the PC time is not synchronized with the device time.
-
Pre-alarm recordings are not visible on the timeline.
-
There is no alarm/motion icon shown during playback of alarm/motion recordings.
-
Exporting video with one or more gaps will result in one solid video track.
-
No text search supported on ATM/POS recordings.
-
Intuikey keyboard 'search', 'freeze' and 'play' functions are not supported.
-
The default for the recording schedule is set for regular recording for all inputs. This
means that all inputs are recorded, even when no camera is connected, and you may
use up extra recording space. You can avoid this by disabling the recording schedule for
a camera that is not available or not connected.
-
The 'File Association' setting in Archive player is disabled in this release.
-
The Archive Player will not be downloaded from the DVR when archiving is performed
via Web Client. Use the Archive Player available on the Bosch website (and on the
product CD), or download it by performing a local archive.
-
The DVR records to different video package files. During continuous recording, you can
set the duration for every package ('Pack Duration' setting). This means you can later
choose in the 'Search/Playback' screen to search for a video via the time line, or from a
list of all recorded files where video packages for Regular (R), Motion (M) or Alarm (A)
recordings are indicated. You can simply click on the required file to view this recording,
or you select one or more files for archiving.
3.2
Version 1.1.0
File name: DVR.V1.1.0.LB.R.20131112.bin (date 2013-11-12)
This release includes the following new features/improvements:
Supports a full bandwidth control. This means that, when the bandwidth limitation is active,
-
all DVR network communication will be limited to the selected bandwidth setting.
Bandwidth limit can be set to off (default), 256 kbps, 512 kbps and higher. For example,
-
when the bandwidth limitation is set to 256 kbps, than the network traffic will not exceed the
256 kbps.
In this version the bandwidth limitation can be set active via a BVC site.xml connection.
-
Therefore BVC will inform DVR if it should stream with or without bandwidth limit.
Document type
Release notes
Release #
SAP/Doc number
V2.3.1 (2015-10-23)
Release date
2015-10-28
Page 8 of 22