Download Print this page

Philips PAN44 Manual page 7

Smart energy plug

Advertisement

Precision = 2
Size = 1 (1 Byte of PF)
Meter Value 1 = 0x63(PF) (It means that the load power factor is 0.99)
3. Z-Wave's Configuration
Configuration
Size
Function
Parameter
(Byte)
1
Watt Meter
Report Period
KWH Meter
Report Period
2
3
Threshold of
current for Load
caution
4
Threshold of
KWh for Load
caution
5
Restore switch
state mode
Mode of Switch
6
Off function
7
LED indication
mode
8
Watt differential
mode
Value
Unit
Default Description
2
0x0000
5s
720
0: Disable Watt
-
Report
0x7FFF
1~32767: 5s~ 45h
0: Disable KWh
0x0000
Report
2
-
10min
6
1~32767:
0x7FFF
10min~ 227days
2
10-1300 0.01A
1300
1300*0.01A
= 13A
2
1-10000 1KWh 10000
10000*1KWh
= 10000 KWh
1
0-2
1
0: Switch off
1: Last switch state
2: Switch on
0: Disable
1
0-1
1
1: Enable
1
1-3
1
1: Show switch state
2: Show night mode
3: One flash mode
1
0-1
1
0 : Disable
1 : 5%
Switch status
9
report mode
3-1 Watt Meter Report Period:
If the setting is configured for 1hour (set value =720), PAN44 will report its
instant power consumption to Group1 node every 1 hour. The maximum inter-
val
to
report
its
instant
(5s*32767/3600=45hr). When the setting is 0, PAN44 will disable Watt auto
report function. The default value is 720.
3-2 KWH Meter Report Period:
If the setting is configured for 1hour (set value =6), PAN44 will report its Ac-
cumulated Power Consumption (KWh) to Group1 node every 1 hour. The
maximum interval to report its Accumulated Power Consumption (KWh) is
227.55 days (10min*32767/1440=227.55 days). When the setting is 0, PAN44
will disable KWH auto report function. The default value is 6.
3-3 Threshold of current for Load Caution
This is a warning when the current of load over the preset threshold value, if
the setting value is 1300, when the load current of Relay1 over this value,
PAN44 will send current meter report to warn the Group1 node, the range of
the setting value is from 10 to 1300, and the default value is 1300.
3-4 Threshold of KWh for Load Caution
This is a warning when the KWh of load over the preset threshold value, If the
setting value is 10000, when the Accumulated Power Consumption of Relay1
over this value, PAN44 will send KWH meter report to warn the Group1
node, minimum value is 1KWh and default value is 10000 kWh.
3-5 Restore switch state mode:
Whenever the AC power return from lost, PAN44 will restore the switch state
2: 10%
3: 15%
4: 10%
0: Disable
1
0-1
1
1:Enable
power
consumption
is
45
hours

Advertisement