Download Print this page

Philips PAN44 Manual page 5

Smart energy plug

Advertisement

Z-Wave's Groups (Association Command Class Version 2)
1.
The Switch can be set to send reports to associated Z-Wave devices. It supports
one association group with one node support for Grouping 1. For group 1, the
Switch will report its latest status to Z-Wave Controller. Grouping 1 includes,
SWITCH_BINARY_REPORT, METER_REPORT, ALARM_REPORT.
2-1 Auto report to Grouping 1 (Maximum Node 5)
2-1-1 On/Off Event Report
When "on" or "off" state has been changed, it will send Binary Switch Report
to the node of Grouping 1.
Binary Switch Report
ON: [Command Class Switch Binary, Switch Binary Report, Value
=255(0xFF)]
OFF: [Command Class Switch Binary, Switch Binary Report, Value
=0(0x00)]
2-1-2 Instant Power Consumption vary over 5% report
When the power consumption of load varies over 5%, it will send Meter report
to the nodes of Grouping 1.
Meter Report Command:
[Command Class Meter , Meter Report , Rate Type = 0x01 , Meter
Type = 0x01,Precision = 1,Scale = 0x02,Size = 4,Meter Value(W) ]
2-1-3 Overload alarm report
When PAN44 detects the current is more than 14.5A, it will send Alarm Report
to Group 1 node.
The content of Alarm Report
Alarm report command:
[Command_Class_Alarm, Alarm_Report, Alarm Type = 0x08, Alarm
Level = 0xFF]
2-2 Response to Meter Get Command
The Switch will report its (1) instant Power Consumption (Watt) or (2) accumu-
lated power consumption (KWH) or (3) AC load Voltage (V) or (4) AC load
current (I) (5) load power factor (PF) to Z-Wave Controller after receive the
Meter Get Command from Z-Wave Controller.
2-2-1 Instant Power Consumption (Watt) of Switch
When receiving Meter Get Command, it will report Meter Report Command to
the node.
Meter Get Command: [Command Class Meter, Meter Get, Scale
=0x02(W)]
Meter Report Command:
[Command Class Meter,Meter Report,Rate Type = 0x01,Meter
Type =
0x01,Precision = 1,Scale = 0x02,Size = 4,Meter Value(W) ]
Example:
Meter Value 1 = 0x00 (W)
Meter Value 2 = 0x00 (W)
Meter Value 3 = 0x03 (W)
Meter Value 4 = 0xEA (W)
Meter(W) = Meter Value 3 *256 + Meter Value 4 = 100.2W
2-2-2 Accumulated Power Consumption (KWh)
When receiving Meter Get Command, it will report Meter Report Command to
the node.
Meter Get Command:
[Command Class Meter, Meter Get, Scale = 0x00 KWh)]
Meter Report Command:
[Command Class Meter ,Meter Report,Rate Type = 0x01 , Meter
Type = 0x01,
Precision = 2,Scale = 0x00,Size = 4,Meter Value (KWh)]

Advertisement

loading