3.2.4.3 Instruction 6, Sub Instruction '1' (Ethernet Change Request)
This message is sent to the unit, when the host computer wishes to change the Ethernet settings of the
TLTR3100 unit. The unit does not need to be in remote mode for this to be achieved.
Table 3.14: Ethernet Change Request message format (instruction 6, sub instruction '1')
Message
Set value / example
byte no.
1
2
3
4
5
6
7
'192.168.000.025'
8
23
'255.255.255.000'
24
39
40
'192.168.000.010'
55
56
57
'192.168.000.032'
58
73
74
TLTR3100
Length
(bytes)
02
1
74
1
32
1
6
1
'1'
1
'1'
1
'_'
1
15
'_'
1
15
'_'
1
15
'_'
1
'1'
1
'_'
1
15
?
1
03
1
Peak Communications Ltd.
Description
STX
Number of bytes
Unit address
Instruction number
Sub instruction
DHCP
'0' = Disabled
'1' = Enabled
Separator character
IPv4 address
Separator character
Subnet mask
Separator character
Gateway mask
Separator character
SNMP
'0' = Disabled
'1' = Enabled
Separator character
SNMP trap address
Checksum
ETX
19