Instruction 26 (Serial Communications Settings Change Request); Serial Communications Settings Change Request Message Format (Instruction 26) - PEAK COMMUNICATIONS TLTR3100 Installation And Operating Handbook

Test loop translator
Table of Contents

Advertisement

Installation and Operating Handbook

3.2.3.1 Instruction 26 (Serial Communications Settings Change Request)

Table 3.10: Serial Communications Settings Change Request message format (instruction 26)
Message
Set value / example
byte no.
1
2
3
4
5
6
7
8
9
TLTR3100
Length
(bytes)
02
1
9
1
32
1
26
1
'2'
1
43
1
'5'
1
?
1
03
1
Peak Communications Ltd.
Description
STX
Number of bytes
Unit address
Instruction number
RS232/RS485 selection
'2' = RS232
'4' = RS485
Address
Valid character range is 1 to 255(incl.)
Baudrate
'1' = 300
'2' = 1200
'3' = 2400
'4' = 4800
'5' = 9600
'6' = 19200
Checksum
ETX
15

Advertisement

Table of Contents
loading

Related Products for PEAK COMMUNICATIONS TLTR3100

Table of Contents