Ethernet Reset Settings - PEAK COMMUNICATIONS TLTR3100 Installation And Operating Handbook

Test loop translator
Table of Contents

Advertisement

Breather
Immersion proof breather.
Fuse
The main DC power supply fuse, bulkhead mounting 20mm x 5mm 1 Amp removable by turning.
Power / Alarms / Remote
16 Way male circular on the chassis with connections as shown in table 1.2. The cable must be rated to
cope with 1 Amp continuous use. The alarm contacts are from a dry contact relay, the ratings of which
are shown in table 1.3
Redundancy
12 Way circular connector on the chassis with connections as shown in table 1.4. The 'Ethernet reset' pin,
when shorted to Ground will flash the main unit LED for ≈ 5 seconds, after this time the unit will restart
with the static Ethernet IP settings as shown in table 1.1.
Note that the ethernet reset pins must not be connected to any pin other than ground or per­
manent damage will occur.
Ethernet
Sealed RJ45 connector, the cover of which must remain in place to keep the IP rating when not in use.
RF In
K­Type connector.
RF Out
K­Type connector.
EXT Ref.
TNC connector, input at 10MHz ± 3dBm.
2
FUSE: 20 x 5mm
EXT Ref.
2A MAX
Power/
Alarms/
Remote
Ethernet
RF In
Figure 1.1: Connector view
Table 1.1: Ethernet reset settings
Parameter
IP address
192.168.0.2
Subnet Mask
255.255.255.000
Gateway
192.168.0.1
Peak Communications Ltd.
Installation and Operating Handbook
Status
Redundancy
RF Out
Setting
TLTR3100