Instruction 41 (Unit Status Request Response); Unit Status Request Response Message Format (Instruction 41) - PEAK COMMUNICATIONS TLTR3100 Installation And Operating Handbook

Test loop translator
Table of Contents

Advertisement

Installation and Operating Handbook

3.2.2.2 Instruction 41 (Unit status request response)

Table 3.8: Unit status request response message format (instruction 41)
Message
Set value / example
byte no.
1
2
3
4
'TLTR3100 [3f 4]'
5
'01234'
32
37
'0112.34'
44
45
46
'23/12/02
47
12:34:56'
64
65
66
67
68
TLTR3100
Length
(bytes)
02
1
68
1
32
1
41
1
27
5
7
'0'
1
'0'
1
'0'
1
17
'1'
1
'1'
1
'0'
1
?
1
03
1
Peak Communications Ltd.
Description
STX
Number of bytes
Unit address
Instruction number
Type of unit this is: TLTR3100 [3f 4]
Serial number
Software version number
Summary alarm
'0' = Ok
'1' = Fault
PLO1 fault
'0' = Ok
'1' = Fault
PLO2 fault
'0' = Ok
'1' = Fault
OK Since time/date string
If there is a fault with this part of the unit then the
string is blank
1:1 status
'0' = Offline
'1' = Online
Remote mode
'0' = Local
'1' = Remote
External reference On/Off
'0' = Off
'1' = On
Checksum
ETX
13