Download Print this page

Maintenance; Troubleshooting - TdA DC535Y User Manual

Automatic boom gate

Advertisement

DC535Y/DCZ535Y, DC655Y/DCZ655Y BOOM GATE USER'S MANUAL
15. Transformer: 220V/12Vx2
16. Sampling Transformer: 110V/ 8.8V 4W
17. Alarm Lamp: AC220V
18. Motor Capacitor: 10μF 450V AC
19. Motor: U (Com), V (Positive direction), W (Opposite Direction), E (Earth)
20. Power Input: E (Earth), L (Live), N (Neutral) AC240V

6. Maintenance

Every 3 months check and add grease (2#) regularly in two grease cups. There should be no
water and impurity in grease cup.
Every 6 months check and add oil. Use WA220 oil only. To avoid high pressure in the reducer
casing, please loose the oil screw a little (one or two turns) before using.
Grease cup (2# grease)
Check and tighten the two M10 socket head screws in the driven lever.
Check if all screws and nuts have been tightened firmly except oil screw as shown in Fig.11.
Check if all wires are firmly connected to their respective terminal blocks.
Make sure the bar is correctly fixed.
Check the general state of the balancing spring.
Keep boom gate clean at all times.

7. Troubleshooting

No.
Trouble
The bar fails to close or
1
open fully.
2
The bar opens too slowly.
The indicator light on the
3
control box does not light.
The
remote
4
operating distance is too
short or not far enough.
Red indicator light of the
5
transmitter does not light.
Fig.11
Possible causes
Limit switch
Balancing spring
Fuse blown
control
Battery level may be
low.
Poor contacted.
13
Oil screw (WA220 oil inside)
Note: Loose the oil screw before
using to avoid oil leakage.
Top view
Solutions
Re-adjust the limit switch.
Adjust the balancing spring rod or
replace the balancing spring.
Replace fuse
Replace the battery inside of the
transmitter or try another transmitter.
Replace the transmitter.

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Dcz535yDc655yDcz655y