Introduction; Parts List; Product Specifications; Cable Specifications - HID VertX V1000 Quick Installation Manual

Hide thumbs Also See for VertX V1000:
Table of Contents

Advertisement

VertX V1000 (CS) Quick Installation Guide
I n t r o d u c t i o n
VertX™ CS is the first family of access controllers designed specifically for alarm dealers for direct
connection to central stations. Because it was designed with the central station in mind, VertX CS works
with software from leading central station automation providers, including Bold Technologies, DICE, Micro
Key, and Patriot Systems.
The V1000 is designed to control readers, door contact inputs and relays through the RS-485 loop and any
combination of up to 32 Interface Panels (V100 Door/Reader Interface, V200 Input Monitor Interface and/or
V300 Output Control Interface). In addition, the V1000 Access Controller manages communications with the
central station automated software.
P a r t s Li s t
VertX™ V1000 Access Controller
Note: The V1000 controller has a plastic base and is covered with a Plastic or Mylar cover.
- Lithium Battery
- Mounting screws
- 2.2K EOL resistors
- HID Serial Adapter cable (P/N 70007)
- Quick Installation Guide
- Installation Wiring Diagram Example
Note: One or more VertX Interface panels are required.
Note: A modem and RS-232 Serial cable must be purchased separately if your installation includes a modem.
P r o d u c t S p e c i f i c a t i o n s
Description
Power Supply
Maximum current at 12VDC per V1000
Average operating current at 12VDC
Operating temperature range
Humidity
Ca b l e S p e c i f i c a t i o n s
Cable Type
RS-485 *
4000 feet (1220 m) to host
15 feet (4.57 m) for RS232 Serial
modem cable
RS-232
6 inch (15.24 cm) adapter
Input Circuits *
500 feet (150 m)
Output Circuits *
500 feet (150 m)
October 2006
Description
Specification
12-16VDC
1 Amp
210mA
32°-122°F (0°-50°C)
5% to 95% non-condensing
Length
Use Belden 3105A, 22AWG twisted pair, shielded 100Ω cable, or
equivalent.
Use any RS232 Serial modem cable specified by the modem
manufacturer.
HID Serial Adapter cable, P/N 70007.
2-conductor, shielded, using ALPHA 1292C (22AWG) or Alpha 2421C
(18AWG), or equivalent.
2-conductor, using ALPHA 1172C (22AWG) or Alpha 1897C (18AWG),
or equivalent.
© 2006 HID Global Corporation. All rights reserved.
Quantity
1
1
4
8
1
1
1
Specification
Page 3 of 20