Balluff Network Interface / CC-Link BNI-CCL-104/202/302/305-100-Z001 1 Notes to the User About this guide Structure of the guide Typgraphical Conventions Symbols Abbreviations 2 Safety Intended Use General Safety Notes Meaning of the warnings 3 Getting Started Connection overview Mechanical connection...
Nodes for the user 1.1 About this guide This guide describes the Balluff CC-Link Field bus Module BNI CCL-… which enables expanded communication down to the lowest level so as to provide improved process optimizing and preventive maintenance. This module is IP67 protected and features a rugged metal IP67 housing.
Balluff Network Interface / CC-Link BNI-CCL-104/202/302/305-100-Z001 Safety 2.1 Intended Use The BNI CCL-… serves as a decentral input/output module for connecting to a CC-Link network. 2.2 General Safety Notes Installation and start up Installation and start-up are to be performed only by trained personnel. Any damage resulting from unauthorized manipulation or improper use voids the manufacturer’s...
Balluff Network Interface / CC-Link BNI-CCL-104/202/302/305-100-Z001 Getting Started 3.1 Connection Overview Connection overview for the module type BNI CCL-305-100-Z001. Different overviews are related to different modules. The port interfaces are shown in the following chapters. Mounting hole 10 Standard Output Port Y0 + Y1...
Balluff Network Interface / CC-Link BNI-CCL-104/202/302/305-100-Z001 Getting Started The module is attached using 2 M6 screws and 2 washers. 3.2 Mechanical connection 3.3 Supply voltage connection Power In (7/8 Mini- Change 5 pin, male) Signal Description Actuator supply Sensor and bus communication supply...
Balluff Network Interface / CC-Link BNI-CCL-104/202/302/305-100-Z001 Getting Started The CC-Link connection is made using the M12 sockets Bus In and Bus Out (A-coded). 3.4 CC-Link Connection Bus In: (M12, A-coded, male) Requirement Note Shield B Line (white) Ground (yellow) A Line (blue)
Balluff Network Interface / CC-Link BNI-CCL-104/202/302/305-100-Z001 Technical Data 4.1 Dimensions 4.2 Mechanical data Housing material Die-case zinc, matte nickel plated Enclosure rating per IEC 60529 IP 67 (only when plugged-in and threaded-in) Supply voltage 7/8” 5-pin male and female Input ports / Output ports...
Balluff Network Interface / CC-Link BNI-CCL-104/202/302/305-100-Z001 Remote signals / Data mapping 5.1 Port overview Port 0 Port 4 Port 5 Port 1 Port 2 Port 6 Port 7 Port 3 5.2 Remote I/O 5.2.1 BNI CCL-104-… Signal direction: Signal direction: BNI-CCL-…...
Balluff Network Interface / CC-Link BNI-CCL-104/202/302/305-100-Z001 Remote signals / Data mapping 5.2.3 BNI CCL-302-… Signal direction: Signal direction: BNI-CCL-… → Master module Master module → BNI-CCL-… Device No. Signal name Device No. Signal name RXn0 Port 0, Pin 4 RYn0...
Balluff Network Interface / CC-Link BNI-CCL-104/202/302/305-100-Z001 Remote signals / Data mapping 5.2.4 BNI CCL-305-… Signal direction: Signal direction: BNI-CCL-… → Master module Master module → BNI-CCL-… Device No. Signal name Device No. Signal name RXn0 Port 0, Pin 4 RYn0...
Balluff Network Interface / CC-Link BNI-CCL-104/202/302/305-100-Z001 Remote signals / Data mapping 5.5 Port sensor diagnostic register Reserved Px – Port x (port configuration in section 5.1) 5.6 Channel actuator diagnostic register - Port n Pin m 5.7 Port direction register...
Balluff Network Interface / CC-Link BNI-CCL-104/202/302/305-100-Z001 Display The BNI CCL-… serves as a decentralised input module for connecting to a CC-Link 6.1 General network. With the implemented display, the address and the communication speed is set directly on the BNI CCL… devices.
Balluff Network Interface / CC-Link BNI-CCL-104/202/302/305-100-Z001 Display 6.5 Edit mode The BNI CCL-… serves as a decentralised input module for connecting to a CC-Link network. With the implemented display, the address and the communication speed is set directly on the BNI CCL… devices.
Page 17
Balluff Network Interface / CC-Link BNI-CCL-104/202/302/305-100-Z001 Included Material 7.1 Included Material The BNI CCL consists of the following components: • IO-block • 4 blind plugs M12 • Ground strap • Screw M4x6 • 20 labels • Short guide www.balluff.com...