Warning!
1. Being installed in the rocking object will lead to misoperation.
2. The shaking curtain which is blown by wind will lead to misoperation, please select the suitable installed
place.
3. Being installed in the place where the traffic is busy will lead to misoperation.
4. It will lead to misoperation when there are sparks produced by some equipment nearby.
Troubleshooting
Malfunction
The load will not work
The load work always
The
load
work
identifiable movement
The load will not work despite
movement
The detection distance may multiply for the reflection on microwave electromagnetic field by
the metal or glass materials. Thus, lower the sensitivity to reach the appropriate detection
distance. Never turn the SENS knob to the maximum value to avoid error detection. Also the
surrounding environment will lead to error action, e.g. the automobiles passing by or the
wandering objects caused by the wind. Products should be installed more than 4 meters one
from the other, otherwise the interference among them will cause error action.
The proper use of trimming potentiometer: the trimming potentiometer is used to adjust the
time that sensor light turn on when detects somebody movement and turn off automatically.
The user can adjust the light time according to different needs. In order to carry out the
saving-energy effectively,we suggest that we should decrease the close time automatically.In
addition, due to the continuous sensor function of the microwave sensor lamp,simply
speaking:Timer will time renewedly so as sensor lamp has any induction. Lamp will keep
open once detected movement within the detection range .
The following situation will lead to misoperation
·wrong light-control setting selected
·load faulty
·mains switch OFF
·continuous movement in the detection
zone
without
any
·the sensor not mounted for detecting
movement reliably
·movement occurred, but not identified
by the sensor(movement behind wall,
movement of a small object in immediate
lamp vicinity etc.)
·rapid movements are being suppressed
to minimize malfunctioning
zone you have set is too small
Cause
the
detection
or
Warning!
Remedy
·Adjust setting
·Change load
·Switch ON
·Check zone setting
·Securely mount enclosure
·Check zone setting
·Check zone setting
Need help?
Do you have a question about the LX-MV-360S8-A and is the answer not in the manual?