1 Warnings United States This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
2 Introduction The MS1000-LCD is an electronic chair scale designed for either walking on or being wheeled on to be weighed. The platform has adjustable locking feet and a deck with built-in, front and rear ramp angles. The scale provides accurate weight with an easy-to-read LCD display, which can be easily mounted on the MS1000 guide rail and powered using the included AC/DC power adaptor.
2.5 Front Panel and Keys Never press a key with anything but your finger. Damage to the overlay may result if sharp or rough objects are used. 2.5.1 Display Annunciators Display reading is stable Scale at Zero. Gross weight is 0, Tare is 0 Indicates a Net weight.
Page 8
Zeroes the scale; turns the scale on / off. In Menu mode: cancel an operation and exit from the current working mode. AWT35-100089 Rev AA 8/25...
3 Scale Operation This section covers the scale operations of simple weighing, the Hold and BMI modes and other functions. A warm-up time of 15 minutes is required to stabilize the measured values. 3.1 Simple Weighing ZERO/ON/OFF 1. Power up the scale and zero the display, if necessary, by pressing the key.
3.4 BMI Function This function calculates the BMI index. BMI (Body Mass Index) is an index of weight-for-height that is commonly used to classify underweight, overweight and obesity in adults. ZERO/ON/OFF 1. Power up the scale and zero the display, if necessary, by pressing the key.
The indicator provides special mode settings to accommodate weight movements in the User Menu. Open the Submenu 1 HOLD to enable this mode and change the parameter values: NLD.RNG (10 div), HLD.RNG (5 div), AVG.TIM (5 sec), STB.TIM (15 sec) accordingly. 3.6.1 Automatic Hold Mode (Default) ZERO/ON/OFF 1.
3.6.3 Manual (Toggle) Hold Mode ZERO/ON/OFF 1. Power up the scale and zero the display, if necessary, by pressing the key. Be UNIT sure the scale is displaying weight in your preferred unit of measure. Press the key, if necessary. HOLD 2.
4 Menus There are four menus that allow you to configure, enable, or execute specific functions or options. User and Diagnostics Menu, page • Calibration Menu, page • • Service Configuration Menu, page 17. 4.1 User Menu In the User Menu there are various submenus available to configure specific sections of the scale operating modes, including the print and communication settings.
Page 14
MULTPL SINGLE Com1 output content and format: MULTPL = default format. See Appendix; EH-SCP SINGLE= only displayed content and SCP-12 current status will be output, it’s compatible with NCI-SCP01; Eh-sp2 EH-SCP = command / response mode; Lfuulf SCP-12 = only displayed content and MULTPL Lfuu-- status will be output, it’s compatible with...
Page 15
MULTPL SINGLE Com2 output content and format: EH-SCP MULTPL = default format. See Appendix; SCP-12 SINGLE= only displayed content and Eh-sp2 current status will be output, it’s compatible with NCI-SCP01; Lfuulf EH-SCP = command / response mode; MULTPL Lfuu-- SCP-12 = only displayed content and Lf--lf status will be output, it’s compatible with Appendix...
AVG.TIM Averages weights in Hold mode for: 1~60 1~60 seconds. Average STB.TIM 3*AVG.TI Allows 3*(AVG.TIM) ~ 255 seconds for M ~ 255 stable conditions to be met in Hold mode. Stable Displays Hold mode weight for: HLD.TIM 0 = until HOLD key pressed; 65535 Hold 1~65535 = the scale exits the Hold mode...
4.2.1 Test Menu PRINT ZERO/ON/OFF In general weighing mode, press the keys. Release the keys when the “TEST” message pops up to open the Calibration Menu. The number of calibrations is shown. TARE ZERO/ON/OFF Navigate the menu using the keys, press the key to confirm or the key to cancel the operation / exit the menu.
4.3 Calibration Menu The scale is configured from the factory to match the specified settings for each unit, as defined by the product specifications and sales brochure. Modification of the settings can be accomplished by altering the calibration settings below. Calibration and/or configuration of calibration settings of your scale should be accomplished by a trained service technician using certified weights to ensure proper operation and accuracy.
4.3.2 Calibration Procedure The procedure covers the Line Calibration. You can add up to 1+3 calibration points. Calibration and/or configuration of calibration settings of your scale should be accomplished by a trained service technician using certified weights to ensure proper operation and accuracy. Calibration is not covered under warranty. ZERO/ON/OFF 1.
Page 20
CONFIG SubMenu1 SubMenu2 Option Default Description RESET YES / NO Resets the configuration to factory setting. NONE Do not use. REGULA NONE CANADA See SBI 210-LCD Operation Manual. EUROPE Sets the number of divisions (div) of the PRIM.N 2000 primary unit of measure (lb). Sets the weight division (1 div = 0.5 lb) value of the first unit of measure.
Page 21
Sets the initial zero (power on zero) weight range: IZSM 0~100 0 = no limit; 1~100 = (calibration zero point) ±1%FS ~ (calibration zero point) ±100%FS Sets the weight type as current initial zero WEIGHT point when current weight is inside the IZSM range: CAL.ZRO IN.IZSM...
Page 22
No = disabled. YES / NO COMPAR See SBI 210-LCD Operation Manual. No = disabled. NO / ACCUMU MANUAL See SBI 210-LCD Operation Manual. / AUTO Yes = enables the Geographical Adjustment GEO.CAL Factor in the Calibration Menu. AWT35-100089 Rev AA 22/25...
5 Specifications Part Number Capacity & Resolution MS1000 LCD 500kg x 0.2kg / 1000lb x 0.5lb 810036380263 MS1000 Platform: Size: flat area: 31.5” x 25.2” (800mm x 640mm), including ramps 31.34” x 38.26” (1050mm x 972mm). Material: mild steel with powder coat paint finish. Construction: heavy duty welded channel support;...
Page 24
SINGLE Byte 1 (H1) Byte 2 (H2) Byte 3 (H3) Byte 4 (H4) 0=stable 0= not under capacity 00=compare disable 00=general weighing 1= not stable 1= under capacity 01=lower limit 01=count weighing 0= not at zero point 0= not over capacity 10=ok 10=percent weighing 11=upper limit...
Page 25
X<CR> 58 0d power off the scale, simulate OFF key others <LF>? <CR><ETX> EH-SCP Status Byte 0=Stable weight data 1=Scale in motion 0= Within weighing range 1= Over capacity 0=Within weighing range 1= Under zero 0= Within range 1= Outside zero capture range 0= Not at center of zero 1= Center of zero always 1...
Page 26
Switch to and send standard weight. Same as W above Switch to and send metric weight. Same as W above Un-known commands: others <STX>?<Status Byte><CR> SCP-12 Status Byte1 Status Byte2 0=Scale in motion 1 = Under capacity 1=Stable 0 = Not under capacity 0= Scale at zero 1 = Over capacity 1= Not at zero...
Page 27
Z<CR> 5A 0D Simulate ZERO key:no response from scale. others Un-known commands:<LF>?<CR> EH-SP2 Status Byte Scale in motion Stable weight data Command Response ASCII Read scale weight: <CR> <P>W1W2W3<dp>W3W4<sp>U1U2<sp>MM<sp><sp><CR> <LF><ETX> AWT35-100089 Rev AA 27/25...
Page 28
Brecknell USA Brecknell UK 1000 Armstrong Dr. Foundry lane, Fairmont MN 56031 Smethwick, West Midlands Toll free:800-637-0529 England, B66 2LP Tel:507-238-8702 Tel:+ 44 (0) 8452 466717 Fax:507-238-8271 Fax:+44 (0) 8452 466718 Email:sales@brecknellscales.com Email:sales@brecknellscales.co.uk http://brecknellscales.com http://brecknellscales.com AWT35-100089 Rev AA 28/25...
Need help?
Do you have a question about the MS 1000-LCD and is the answer not in the manual?
Questions and answers