Re m ote T ile

The Remot e Ti le all ows users t o con figur e th e Test S et t o all ow access fr om an exter nal con tro ller.
Dep ending on t he R emote Sou rce se lected, par ameter s may a lso nee d to be con figur ed o n the
Net wo rk T ile.
F i el d D e fi n i t i o n s
R e mot e S o u r ce
F i r ew al l
If Test Set is o perat ing b ehind a net wor k fi re w all, P orts 5800 and 5 900 must be o pened for
pro per VN C o pera tion. C onta ct your IT D epart m ent for pro per netw ork configu rat ion.
G PI B
Ena bles GPI B remote oper atio n. Sele ct ing GP IB req uires an ad dress to be set in t he GPI B
Add ress f ield.
T C P /I P
TC P/I P e nables remot e oper atio n over an ether net connect ion. When TC P/ IP is select ed, a
value mu st be defi ned in the TC P/I P Por t f ield. U se of TC P/I P also r equir es net wor k access
wh ich is co nfigur ed o n th e U tilit ies N etw ork Tile.
G PI B A d d r e ss
The GP IB Ad dress field sets t he T est S et's primar y G PI B a ddress for use w ith G PIB r emote
oper ation .
T C P /I P Por t
The TCP /I P P ort fie ld set s Test Se t por t for use w ith TC P/I P remote oper atio n.
VN C Vi e we r Pa ss w or d
The V NC View er Passw ord f ield sets t he passw ord r equir ed for VN C clien t to access the Test S et
via t he et hern et.
T est Set U til it y Ti les
Fig. 4- 22 UTI LS Remot e Ti le
S u b j e ct t o E x p o r t C o n tr o l , s ee C o ve r P a g e f o r d e t ai l s .
4- 19