_________________________________________________________________5. WORKING
for 15 seconds. When the power regulator is placed on 100, its heating
element is always on (provided the
5.2.11
Oven roof
Both oven roof and bedplate pilot lamps turn on when the
on and its power regulator is switching on within the regulation cycle, to
indicate that its heating element is actually on.
position
10
20
30
40
50
60
70
80
90
100
5.3 Error display
5.3.1 Short-circuited thermocouple (vers. TERM0012)
When the thermocouple is across the line (short circuit), the
display shows "---".
5.3.2 Disconnected thermocouple (vers. TERM0012)
When the thermocouple is disconnected or interrupted, the
display shows "EEE".
The same code of error appears if the baking chamber temperature
exceeds the maximum temperature that can be selected.
5.3.3 Disconnected thermocouple (vers. TERM0060)
When the thermocouple is disconnected or interrupted, the
display shows "PR1".
The same code of error appears if the baking chamber temperature
exceeds the maximum temperature that can be selected.
____________________________________________________________________________
20
CITIZEN 6 - 9/MC, CITIZEN 6+6 - 9+9/MC ELECTROMECHANICAL VERSION
display is on ).
and bedplate
power regulation
no. secs. to switch on
3
6
9
12
15
18
21
24
27
30
pilot lamps
no. secs. to switch off
display is
27
24
21
18
15
12
9
6
3
0