Table 1-5. Switching Time Sample (msec)
Switch Size
a
Switch
1×4
HP 86060C,
HP 86061C
1×8
HP 86060C,
HP 86061C
1×56
HP 86062C
1×100
HP 86062C
a. Note that the switch mechanism used for channel count greater than 48 is different, hence switching time.
b. Switching time = (switching between starting and adjacent channel) + (additional time/channel) × remaining channel increments to reach
last channel.
Table 1-6. General Specifications (1 of 2)
OPTICAL CONNECTORS
a
Option 012
Option 014
Option 017
GENERAL SPECIFICATIONS
Temperature Range
Operating
Storage
Humidity
Operating
Storage
Altitude
EMI Compatibility
Power Requirements
Power Consumption
Installation Category
Pollution Degree
Starting Channel to
Adjacent Channels
290
290
258
258
,
,
b
c
FC/PC connectors
ST connectors
SC connectors
+0°C to +55°C
–40°C to +70°C
Maximum relative humidity 95% for temperatures up to 40°C (non-condensing)
Maximum relative humidity less than 90% at 65
Altitude up to 15,000 feet (4,572 meters).
Conducted and radiated emissions meet the requirements of CISPR Publication 11 and
EN 55011 Group 1, Class A.
100/115/230/240 V (range 90 to 254 Vac),
50/60 Hz (range 47 to 63 Hz)
Up to 80 VA
Category II per I.E.C. 1010
Degree 2 per I.E.C. 664
Specifications and Regulatory Information
Plus Additional
Maximum
Time/Channel
Switching Time
40
370
40
530
7.5
663
7.5
993
°