Initial Set Up - Graco 255828 Operations & Parts List

Ar pour gun
Table of Contents

Advertisement

Initial Set Up

Initial Set Up
1. Remove coupling block from gun.
2. Check valving rod clearance in closed position. Rod
should extend approximately 1/32 in. (1 mm)
beyond tip of mixing chamber.
3. Adjust valving rod travel to initial setting. See Valv-
ing Rod and Resilient Sleeve, page 17.
4. Connect air supply hose to gun.
5. Connect A-isocyanate hose (red-taped) to notched
fitting on coupling block. Then connect R-resin hose
(blue-taped) to fitting without notches on coupling
block.
6. Close both manual valves.
7. Pressurize the A and R chemical hoses and check
for leaks. (See Proportioning Unit manual.)
8. Bleed air from chemical hoses:
a. Hold coupling block with exit ports pointed into
disposable container.
b. Open each manual valve to allow trapped air to
escape. Bleed each side until chemical is free of
air.
c. Close both manual valves.
9. Use clean cloth soaked in gun cleaner to wipe clean
coupling block and its mating surfaces.
CAUTION
To avoid accumulation of dirt and other contaminants,
do not apply grease to mating surfaces of coupling
block.
10. Install coupling block to gun block.
11. Proceed with Daily Start-up procedure or Shutdown
procedure as required.