Acoustic Signal Generator; Real-Time Clock; Tab. 15 Hitch Position - Analog Input According To Iso11786:1995; Tab. 16 Ignition - Jetter JVM-206-K00-O21 Translation Of The Original User Manual

Table of Contents

Advertisement

Jetter AG
Hitch position (ana-
log input)
Ignition input/out-
put

4.11 Acoustic signal generator

4.12 Real-time clock

JVM-206-K00-O21 User Manual
Category
ISO11786 - Hitch position (analog input)
Abbreviation
Quantity
Voltage range
Input resistance
Tab. 15: Hitch position - analog input according to ISO11786:1995
Category
Ignition input/output
Abbreviation
Quantity
Input
Power supply
Output
Max. output current
Tab. 16: Ignition
Category
Type
Volume
Volume control
Frequency band
Tab. 17: Acoustic signal generator
Parameter
Battery type
Service life
Description
TP_AI_IN
1
0 ... 10 V
> 3 kOhm
Description
IGN_KEY
1
12 V
0.5 A
Description
Piezo
> 70 dB
Switched off,
10% ... 100%
200 Hz ... 4 kHz
Description
CR2032
Approx. 10 years from
production
Technical specifications | 4
At resonant frequency
without mechanical at-
tenuation
Controlled via PWM
The battery life depends
on the environmental
conditions and may
therefore vary.