Ports And Interfaces; Isobus Interface; Usb Interface; Tab. 10: Emission To Cispr 25 - Jetter JVM-206-K00-O21 Translation Of The Original User Manual

Table of Contents

Advertisement

Jetter AG
Emission to CISPR
25
ESD EN 61000-4-2

4.9 Ports and interfaces

4.9.1 ISOBUS interface

4.9.2 USB interface

JVM-206-K00-O21 User Manual
Emission to CISPR 25
Narrowband emission
30 MHz ... 1000 MHz
Wideband emission
30 MHz ... 1000 MHz
Tab. 10: Emission to CISPR 25
ESD EN 61000-4-2
Contact ±4 kV
Air ±8 kV
Tab. 11: ESD EN 61000-4-2
Parameter
Baud rate
Protocol
Terminating resistor
Cable specification
Category
Supply unit
Data rate
Protocol
Limit
30 ... 75 MHz = 52 ... 42 dBµV/m (decreasing over
logarithm)
75 ... 400 MHz = 42 ... 53 dBµV/m (increasing over
logarithm)
400 ... 1000 MHz = 53 dBµV/m (constant)
30 ... 75 MHz = 62 ... 52 dBµV/m (decreasing over
logarithm)
75 ... 400 MHz = 52 ... 63 dBµV/m (increasing over
logarithm)
400 ... 1000 MHz = 63d BµV/m (constant)
Functional class
O
O
Description
250 kBaud
ISOBUS
Integrated
CAN-compliant, twisted wires, unshielded
Description
5 V, 500 mA max.
USB 1.1
USB host interface
Technical specifications | 4
12 / 32

Advertisement