Completely read through the operating instructions as
!
well as the latest information under the internet link at
the end of these instructions. Follow the instructions
they contain. This document must be kept in a safe
place and passed on together with the device.

General safety instructions

– The device must only be used in accordance with its
intended purpose and within the scope of the specifications.
– Modifications or changes to the device are not permitted, this
will otherwise invalidate the approval and safety specifications.
– Do not expose the device to mechanical stress, extreme
temperatures, moisture or significant vibration.
– Do not point the beam of light directly into the eyes of people,
particularly those wearing glasses or contact lenses
(high dazzling effect) or animals.
– Under no circumstances should you look directly into the light
produced by this device or when it is reflected off specular
surfaces. 
– Close your eyes and move your head away from the beam of
light if optical radiation hits your eyes.
– Avoid heat build-up during use, for example, due to the covering
the device.
– Do not place the lamp in front of inflammable material when
in use. It could ignite.
– Do not use the lamp in traffic.
– Do not leave the lamp unsupervised with children.
– Before using the lamp for the first time, the battery must be
fully charged.
– The red charging indicator lights up during charging.
– The green charging indicator lights up when charging is
completed.
– Recharge frequently.
– Always replace the battery with an original 4K5 battery.
– Do not leave the battery without charge for an extended
period. Deep discharge risks damaging the battery.
– The light source of this lamp is not replaceable; when the light
source reaches its end of life the whole lamp shall be replaced.
Safety instructions
Danger - powerful magnetic fields
– Powerful magnetic fields can adversely affect persons with active
medical implants (e.g. pacemaker) as well as electromechanical
devices (e.g. magnetic cards, mechanical clocks, precision
mechanics, hard disks).
– With regard to the effect of powerful magnetic fields on
persons, the applicable national stipulations and regulations
must be complied with such as BGV B11 §14 „electromagnetic
fields" (occupational health and safety - electromagnetic fields)
in the Federal Republic of Germany.
– To avoid interference/disruption, always keep the implant or
device a safe distance of at least 30 cm away from the magnet.