  • Page 1 MANUALE D’ISTRUZIONE OWNER’S MANUAL CUBE HYBRID 8,4m 4x150W LED TL203-01-12-00 DISCOVER battery 16-07-2018 YANMAR ENGINE Italiano - English...
  • Page 2: Table Of Contents

    CUBE HYBRID 8,4m 4x150W LED INDICE – INDEX MARCATURA CE - CE MARK ........................4 USO E MANUTENZIONE - USE & MAINTENANCE ................... 4 INFORMAZIONI GENERALI - GENERAL INFORMATION ................ 5 CERTIFICATO DI QUALITÀ - QUALITY SYSTEM ..................5 DICHIARAZIONE DI CONFORMITÀ E SCHEDA DI COLLAUDO – DECLARATION OF CONFORMITY WITH CHECK LIST ............................
  • Page 3 CUBE HYBRID 8,4m 4x150W LED IDENTIFICAZIONE DEI COMPONENTI INTERNI - IDENTIFICATION OF INNER COMPONENTS ..29 DESCRIZIONE DEI COMANDI – CONTROLS DESCRIPTION ............... 29 13.1 BATTERIE RICARICABILI ALIMENTAZIONE PROIETTORI – SUPPLY FLOODLIGHT RECHARGE 13.2 BATTERY ..............................31 CARICA BATTERIE ELETTRONICO – ELECTRONIC BATTERY CHARGE ........... 32 13.3 BATTERIA AVVIAMENTO MOTORE –...
  • Page 4: Marcatura Ce - Ce Mark

    CUBE HYBRID 8,4m 4x150W LED 1. MARCATURA CE - CE MARK La marcatura CE (Comunità Europea) attesta The CE mark (European Community) certifies che il prodotto è conforme ai requisiti that the product complies with essential essenziali di sicurezza previste dalle Direttive safety requirements provided...
  • Page 5: Informazioni Generali - General Information

    CUBE HYBRID 8,4m 4x150W LED INFORMAZIONI GENERALI - GENERAL INFORMATION La torre faro è stata progettata, costruita e The lighting tower is designed, produced and collaudata per soddisfare le vigenti normative tested to meet the European rule and to Europee nel ridurre al minimo i rischi elettrici e reduce at the minimum the electrical risks in nel rispetto delle vigenti norme.
  • Page 6: Simboli Di Sicurezza - Safety Signs

    CUBE HYBRID 8,4m 4x150W LED SIMBOLI DI SICUREZZA - SAFETY SIGNS Questi simboli avvertono l’utente su eventuali These signs inform the user of any danger pericoli che possono causare danni a persone. which may cause damages to persons. Leggere il significato e le precauzioni descritte Read the precautions and meant described in nel manuale.
  • Page 7 CUBE HYBRID 8,4m 4x150W LED Simboli di divieto Significato Meant Prohibition signs  It is prohibited to clean, to  Divieto di pulire, lubrificare lubricate and to regulate e registrare organi in moto organs in motion.   Divieto di spegnere incendi It is prohibited to extinguish con acqua, utilizzare solo fires with water, use only...
  • Page 8: Norme Di Sicurezza Da Osservare - Safety Regulations To Observe

    CUBE HYBRID 8,4m 4x150W LED 7. NORME DI SICUREZZA DA OSSERVARE - SAFETY REGULATIONS TO OBSERVE costruttore è responsabile The manufacturer is not responsible of eventuali danni persone cose, damage things persons, conseguenti l’inosservanza delle norme di resulting as consequence of inobservance sicurezza.
  • Page 9: Prima Dell'uso Della Macchina - Before The Use Of Machine

    CUBE HYBRID 8,4m 4x150W LED PRIMA DELL’USO DELLA MACCHINA – BEFORE THE USE OF MACHINE Deve essere posizionata una transenna posta A barrier shall be placed 2 meters around a 2 metri di distanza attorno alla torre faro per the light tower to prevent unauthorized impedire al personale non autorizzato di personnel to approach the machine.
  • Page 10: Note - Commentary

    CUBE HYBRID 8,4m 4x150W LED Connections to true earth examples; the Esempi di connessione a terra. Le seguenti followings are examples of feasible methods, connessioni sono esempi di metodi fattibili: using: (1) an earth rod driven to a proper depth; (1) un dispersore spinto a una profondità...
  • Page 11 CUBE HYBRID 8,4m 4x150W LED (2) per la protezione delle persone in caso di (2) for user protection in case of contact contatto tra un conduttore attivo e terra o between a live conductor and true earth or struttura metallica. metallic enclosure.
  • Page 12: Durante La Manutenzione - During The Maintenance

    CUBE HYBRID 8,4m 4x150W LED DURANTE LA MANUTENZIONE - DURING THE MAINTENANCE Spegnere sempre la macchina prima di ogni Maintenance operations shall be carry out intervento di manutenzione. on the unit at rest. La manutenzione straordinaria deve sempre Ordinary and/or extraordinary maintenance essere effettuata da personale autorizzato.
  • Page 13: Informazioni Generali Di Pericolo - General Danger Information

    CUBE HYBRID 8,4m 4x150W LED 8. INFORMAZIONI GENERALI DI PERICOLO - GENERAL DANGER INFORMATION PERICOLO DI USTIONI - DANGER OF BURN Non toccare con le mani superficie calde, Avoid contact with hot surfaces, mufflers, quali marmitte e relative prolunghe e corpo del silencers with relatives extensions and motore quando questo è...
  • Page 14: Pericolo Correlati Alle Batterie - Danger Involved With Batteries

    CUBE HYBRID 8,4m 4x150W LED PERICOLO CORRELATI ALLE BATTERIE - DANGER INVOLVED WITH BATTERIES Lavorare in prossimità di una batteria è Working close to a battery is dangerous.. pericoloso. Non fumare né generare scintille o Never smoke or allow a spark or flame close fiamme in prossimità...
  • Page 15: Pericolo Di Incendio O Esplosione Durante Le Operazioni Di Rifornimento - Warning Of Fire Or Explosion During Operations Of Refueling

    CUBE HYBRID 8,4m 4x150W LED PERICOLO DI INCENDIO O ESPLOSIONE DURANTE LE OPERAZIONI DI RIFORNIMENTO - WARNING OF FIRE OR EXPLOSION DURING OPERATIONS OF REFUELING Spegnere sempre il motore prima di effettuare Turn off the unit before refuelling operations. il rifornimento di carburante. Non fumare durante i rifornimenti.
  • Page 16: Descrizione Generale Della Macchina - General Description Of The Machine

    CUBE HYBRID 8,4m 4x150W LED 9. DESCRIZIONE GENERALE DELLA MACCHINA - GENERAL DESCRIPTION OF THE MACHINE La torre faro CUBE HYBRID è una torre The lighting tower CUBE HYBRID has been d’illuminazione disegnata tenendo studied taking in consideration 3 fundamental considerazione 3 caratteristiche fondamentali: characteristics: ...
  • Page 17: Caratteristiche Tecniche - Technical Specification

    CUBE HYBRID 8,4m 4x150W LED 11. CARATTERISTICHE TECNICHE - TECHNICAL SPECIFICATION 11.1 ALTERNATORE – ALTERNATOR Modello Linz E1C10 Model 11.2 GENERATORE – GENERATOR Sincrono Modello Model Synchronous 5 kVA Potenza nominale Rated Apparent power 230÷240 V Tensione nominale (monofase) Rated voltage (single phase) Uscita ausiliaria monofase 2,5 kVA Single phase auxiliary...
  • Page 18: Centralina Idraulica - Hydraulic Gear Box

    CUBE HYBRID 8,4m 4x150W LED 11.4 CENTRALINA IDRAULICA – HYDRAULIC GEAR BOX 11.4.1 MOTORE ELETTRICO – ELECTRICAL MOTOR 230÷240 V 50-60 Hz ± Alimentazione Feeding Potenza 0,55 kW Power Poli Poles Fattore di carico Duty factor 11.4.2 POMPA IDRAULICA – GEAR PUMP Cilindrata 1,3 cm Displacement...
  • Page 19: Torre Faro - Lighting Tower

    CUBE HYBRID 8,4m 4x150W LED 11.5 TORRE FARO – LIGHTING TOWER Altezza massima 8,4 m Maximum height Idraulico – Hydraulic Sollevamento Raising Sezioni Section Rotazione 340° Rotation Section Cavo elettrico spiralato 11G2,5 mmq Electrical coiled cable Cavo elettrico di cablaggio dei H07RN-F Electrical cable of floodlights proiettori...
  • Page 20: Batterie Alimentazione Proiettori - Battery Power Floodlight

    CUBE HYBRID 8,4m 4x150W LED 11.7 BATTERIE ALIMENTAZIONE PROIETTORI – BATTERY POWER FLOODLIGHT 11.7.1 BATTERIA - BATTERY IEC60896-21/22 BS EN 60254-1:2005 Compliance with applicable Normre di riferimento AS/NZS 4029.2.2000 BS EN standards 60254-1:2005 (MOD) Battery’s amount Quantità batterie Tensione nominale batteria Battery rated voltage Tensione nominale delle batterie 24 V...
  • Page 21: Caratteristiche Elettriche - Electrical Characteristics

    CUBE HYBRID 8,4m 4x150W LED 11.7.2 CARATTERISTICHE ELETTRICHE – ELECTRICAL CHARACTERISTICS 2.27 V/el – 2.27 V/elc Tensione di mantenimento a 25°C Float voltage charge at 25°C 2.45 V/el – 2.45 V/el Tensione di ricarica Float voltage 11.7.3 SCARICA IN CORRENTE COSTANTE PER ELEMENTO FINO A 5.7 V A 25°C - DISCHARGED CONSTANT AMPS TO 5.7 V AT 25°C [A] Ampere Tempo di scarica [minuti] Discharge Time [minutes]...
  • Page 22: Inverter - Power Inverter

    CUBE HYBRID 8,4m 4x150W LED 11.8 INVERTER – POWER INVERTER Tensione DC ingresso DC 18,4-34,0 V DC input voltage Potenza continuativa 1200 W Output power Potenza di picco 2400 W Output power surge Warning batteria scarica 21,8 V Low battery warning Shutdown batteria scarica 18,6 V Low battery shut down...
  • Page 23 CUBE HYBRID 8,4m 4x150W LED L’inverter deve rimanere sempre acceso: The inverters have to be always turned on: verificare che il tasto “On-Off-Eco” sia sulla verify that the “On-Off-Eco” button is on “On” posizione “On”. position. I led rosso e verde segnalano le seguenti Red and green leds signal alarm or fault on anomalie dell’inverter: the inverter:...
  • Page 24 CUBE HYBRID 8,4m 4x150W LED LED rosso Definizione Risoluzione dei problemi Red LED Definition Trouble shooting • • • • • • • • Sovraccarico Ridurre il carico Luce on • • • • • • • • Overload Reduce load Solid on Ricaricare o sostituire la batteria.
  • Page 25: Proiettore - Floodlight

    CUBE HYBRID 8,4m 4x150W LED 11.9 PROIETTORE – FLOODLIGHT Lampada Lamp Potenza 4x150 W Power Flusso luminoso 17660 lm Luminous flux IP 65 Grado di protezione moduli Degree of protection Temperatura di esercizio -30°C to +45°C Operating temperature range Alluminio trafilato nero – Materiale corpo lampada Trafilated aluminium Lamp body material...
  • Page 26: Identificazione Dei Componenti Esterni - Identification Of External Components

    CUBE HYBRID 8,4m 4x150W LED 12. IDENTIFICAZIONE DEI COMPONENTI ESTERNI - IDENTIFICATION OF EXTERNAL COMPONENTS 12.1 COMPOSIZIONE DELLA TORRE FARO - LIGHTING TOWER COMPOSITION Pos. Descrizione Description Items Sportello ispezione motore con quadro di Engine inspection door with command comando panel Sportello ispezione motore Engine inspection door...
  • Page 27 CUBE HYBRID 8,4m 4x150W LED Pos. Descrizione Description Items Piastre per trasporto tramite carrello Plate for transport through forklift elevatore Griglia entrata aria Air inlet grid Sportello ispezione motore Engine inspection door Griglia uscita aria Air outlet grid Maniglie rotazione proiettori Floodlights rotation handles Palo telescopico Telescopic mast...
  • Page 28: Quadro Elettrico Esterno - External Electrical Panel

    CUBE HYBRID 8,4m 4x150W LED 12.2 QUADRO ELETTRICO ESTERNO - EXTERNAL ELECTRICAL PANEL Pos. Descrizione Description Items Pulsante stop d’emergenza Emergency stop button Morsetto di messa a terra Earth clamp connection Numero di matricola Serial number TL203-01-12-00 DISCOVER battery 16-07-2018 YANMAR ENGINE Italiano - English...
  • Page 29: Identificazione Dei Componenti Interni - Identification Of Inner Components

    CUBE HYBRID 8,4m 4x150W LED 13. IDENTIFICAZIONE DEI COMPONENTI INTERNI - IDENTIFICATION OF INNER COMPONENTS 13.1 DESCRIZIONE DEI COMANDI – CONTROLS DESCRIPTION 34 33 32 31 TL203-01-12-00 DISCOVER battery 16-07-2018 YANMAR ENGINE Italiano - English...
  • Page 30 CUBE HYBRID 8,4m 4x150W LED Pos. Descrizione Description Items Presa monofase 230÷240 V 16 A 2P+T IP67 230÷240 V 16 A 2P+E IP67 EEC single phase socket 230÷240 V 15 A 2P+E single phase 19 (*) Presa monofase 230÷240 V 15 A 2P+T socket Selettore “Off/Manuale/Relè...
  • Page 31: Batterie Ricaricabili Alimentazione Proiettori - Supply Floodlight Recharge Battery

    CUBE HYBRID 8,4m 4x150W LED 13.2 BATTERIE RICARICABILI ALIMENTAZIONE PROIETTORI – SUPPLY FLOODLIGHT RECHARGE BATTERY Pos. Descrizione Description Items Batterie 230 Ah 230 Ah battery Fusibile 80 A protezione batterie 80 A fuse battery protection Interruttore stacca batteria Battery switch Fusibile 2 A protezione monitor di lettura 2 A fuse 24 V battery monitor protection batterie 24 V...
  • Page 32: Carica Batterie Elettronico - Electronic Battery Charge

    CUBE HYBRID 8,4m 4x150W LED 13.3 CARICA BATTERIE ELETTRONICO – ELECTRONIC BATTERY CHARGE Pos. Descrizione Description Items Tasto selezione modalità visualizzazione Display visualization mode button display Display Display Indicatore rosso, carica a bulk e di Red indicator, recharging bulk- assorbimento absorbment stage Orange indicator, recharging equalization Indicatore arancio, fase di equalizzazione...
  • Page 33 CUBE HYBRID 8,4m 4x150W LED tasto (41) seleziona modalità (41) button selects display visualizzazione del display e dopo 10 secondi visualization mode, if not operated, after 10 circa il display torna a visualizzare la corrente seconds, the display visualizes the charge di carica.
  • Page 34: Batteria Avviamento Motore - Engine Starter Battery

    CUBE HYBRID 8,4m 4x150W LED 13.4 BATTERIA AVVIAMENTO MOTORE – ENGINE STARTER BATTERY Pos. Descrizione Description Items Batteria 44 Ah 12 V 44 Ah 12 V battery Interruttore stacca batteria Battery switch La macchina è fornita con la batteria collegata The unit is supplied with the battery e stacca batteria scollegato.
  • Page 35: Centralina Idraulica - Hydraulic Gear Box

    CUBE HYBRID 8,4m 4x150W LED 13.5 CENTRALINA IDRAULICA - HYDRAULIC GEAR BOX Pos. Descrizione Description Items Motore centralina idraulica Engine hydraulic gear box Perno per discesa palo in caso d’emergenza Lowering pin in case of emergency Tappo serbatoio olio idraulico Hydraulic oil tank cap Serbatoio olio idraulico Hydraulic oil tank...
  • Page 36: Manopola Discesa Palo In Caso D'emergenza - Lowering Handle Bar Bracket In Case Of Emergency

    CUBE HYBRID 8,4m 4x150W LED 13.5.1 MANOPOLA DISCESA PALO IN CASO D’EMERGENZA - LOWERING HANDLE BAR BRACKET IN CASE OF EMERGENCY ATTENZIONE !!! WARNING !!! Quando a palo alzato accade un’avaria al When the mast is raised, in case of the damage of the engine, it’s possible to came motore del generatore o al motore della centralina idraulica, è...
  • Page 37: Serbatoio Carburante - Fuel Tank

    CUBE HYBRID 8,4m 4x150W LED 13.6 SERBATOIO CARBURANTE - FUEL TANK Pos. Descrizione Description Items Tappo serbatoio carburante Fuel tank cap Riempire il serbatoio di gasolio rispettando la Fill up the diesel fuel tank taking into account capacità del serbatoio (lt. 170). L’autonomia è the tank capacity (lt.
  • Page 38: Controllo Livello Olio Motore - Check Engine Oil Level

    CUBE HYBRID 8,4m 4x150W LED 13.7 CONTROLLO LIVELLO OLIO MOTORE – CHECK ENGINE OIL LEVEL 53-b 53-a Pos. Descrizione Description Items Tappo olio motore con asta di livello Engine oil cap /dipstick 53-a (*) Tappo olio motore Engine oil cap 53-b (*) Asta di livello olio Engine oil dipstick...
  • Page 39: Sostituzione Olio Motore - Change Engine Oil

    CUBE HYBRID 8,4m 4x150W LED 13.8 SOSTITUZIONE OLIO MOTORE - CHANGE ENGINE OIL Pos. Descrizione Description Items Tappo scarico olio Engine oil drain cap Estrarre il tubo dal telaio della macchina Extract rubber hose from frame inserendolo in una bacinella. Togliere il tappo introducing it in a small basing.
  • Page 40: Puntazza Di Messa A Terra E Porta Documenti - Earthing Rod And Box Document

    CUBE HYBRID 8,4m 4x150W LED 13.9 PUNTAZZA DI MESSA A TERRA E PORTA DOCUMENTI - EARTHING ROD AND BOX DOCUMENT Pos. Descrizione Description Items Porta documenti Box document Puntazza di messa a terra l.1000mm L.1000mm earth rod Earth rod with earth conductor (56) are Sulla macchina è...
  • Page 41: Istruzioni Per L'uso - Operating Instructions

    CUBE HYBRID 8,4m 4x150W LED 14. ISTRUZIONI PER L’USO - OPERATING INSTRUCTIONS 14.1 TRASPORTO DELLA TORRE FARO – TRANSPORT OF THE LIGHTING TOWER  There are many options to move lighting Per trasportare la torre faro ci sono diverse possibilità. tower.
  • Page 42: Avvertenze - Remarks

    CUBE HYBRID 8,4m 4x150W LED 14.2 AVVERTENZE - REMARKS Gli operatori che utilizzano l’unità devono aver Users shall fully know the safety regulations involving the unit. Chapter 7 shall be taken compreso a fondo le prescrizioni di sicurezza riportate al paragrafo 7. as reference.
  • Page 43: Collegamento Della Batteria - Connecting Of The Battery

    CUBE HYBRID 8,4m 4x150W LED In caso di utilizzo della torre faro in situazioni electrical connection between ambientali avverse, con temperature troppo floodlights and the command panel of the basse o alte, prestare attenzione al cavo lighting tower is ensured by means of a turn spiralato suo normale scorrimento...
  • Page 44: Controlli Preliminari - Preliminar Checks

    CUBE HYBRID 8,4m 4x150W LED 14.5 CONTROLLI PRELIMINARI - PRELIMINAR CHECKS All’acquisto la macchina è fornita di olio motore The unit is supplied with proper engine e olio idraulico. lubricant and hydraulic oil quantities. Prima di ogni successivo utilizzo, verificare i Before each use,...
  • Page 45: Posizionamento Della Torre Faro - Lighting Tower Positioning

    CUBE HYBRID 8,4m 4x150W LED torre faro è predisposta The hybrid system can run in Manual or funzionamento dell’accensione sia in modo Automatic mode. manuale che automatico. Un sensore crepuscolare montato a bordo A light intensity sensor mounted on the macchia comandato da una logica, consente control panel allows controlling the LEDs l’accensione dei proiettori e allo spegnimento,...
  • Page 46: Stabilizzatore - Stabiliserzs

    CUBE HYBRID 8,4m 4x150W LED 14.8.2 STABILIZZATORE – STABILISERZS Sganciare i perni dalle loro sedi (Fig. 5) (sono Release the pins from their hole (Fig. 5) (are posti all’interno della macchina), e procedere placed inside the machine), and then proceed manualmente all’estrazione dello stabilizzatore manually to the extraction of stabilizers until fino a che i perni bloccano la fuoriuscita del...
  • Page 47: Regolazione Palo - Mast Adjustments

    CUBE HYBRID 8,4m 4x150W LED 14.8.3 REGOLAZIONE PALO – MAST ADJUSTMENTS Portare interruttori magnetotermici Switch ON (I) the RCD and all circuit differenziale posti sul quadro frontale in breakers on the control panel. posizione “ON” (I). Selezionare l’alimentazione del sistema tramite Select the unit power source by means of the selettore RETE...
  • Page 48 CUBE HYBRID 8,4m 4x150W LED (Fig. 8) ATTENZIONE: è severamente vietato WARNING: it is strictly prohibited to close richiudere gli stabilizzatori quando la torre the stabilizers when the lighting tower is faro si trova in posizione verticale alla in vertical position at the maximum height. massima altezza.
  • Page 49: Protezioni Elettriche - Electric Protection

    CUBE HYBRID 8,4m 4x150W LED 14.9 PROTEZIONI ELETTRICHE – ELECTRIC PROTECTION Nel seguente capitolo sono descritte le The following chapter describes the electrical protezioni elettriche poste nel quadro di protection devices featured in the control controllo panel. Interruttore magnetotermico differenziale. RCD/MCB.
  • Page 50 CUBE HYBRID 8,4m 4x150W LED PROTEZIONI DIFFERENZIALI RESIDUAL CURRENT PROTECTION Ogni carico elettrico alimentato dall’ unità All load supplied by means of the unit is prevede una protezione differenziale provided RCD protection   Magnetotermico differenziale 16 A 16 A (30mA) RCD/MCB: main (30mA) protezione generale: protection protezione differenziale su tutti i...
  • Page 51: Modalitá Funzionamento - Operating Mode

    CUBE HYBRID 8,4m 4x150W LED 14.10 MODALITÁ FUNZIONAMENTO – OPERATING MODE I comandi principali della torre faro sono posti All control gears, switches and toggles of the all’interno di uno sportello provvisto di maniglia unit are installed on the control cabinet. It is con serratura di sicurezza, per impedire che il provided a door with handle with safety lock personale non autorizzato maneggi i comandi.
  • Page 52 CUBE HYBRID 8,4m 4x150W LED *: la sequenza di accensione dei led è *: Leds igniting sequence is commanded regolata in modo da garantire affidabilità al and controlled in order to ensure system sistema. reliability. Tale sequenza è così caratterizzata: Ignition sequence features are listed below: ...
  • Page 53: Modalità Di Funzionamento Ibrida - Hybrid Operating Mode

    CUBE HYBRID 8,4m 4x150W LED ATTENZIONE: utilizzando la torre faro in WARNING: the 24 V battery charger is modalità MAINS (RETE) il carica batterie always enabled, allowing to keep the 24 V è sempre inserito, permettendo di storage battery charged . The battery mantenere cariche batterie...
  • Page 54: Comando Proiettori Led - Led Triggering

    CUBE HYBRID 8,4m 4x150W LED 14.10.2.2 COMANDO PROIETTORI LED – LED TRIGGERING In modalità IBRIDA i proiettori led vengono HYBRID System works to supply LEDs by alimentati, mediante batterie ricaricabili a means of 24 Vdc storage battery via inverter 24 Vdc tramite inverter, e/o (in funzione dello or (depending on the state of charge of the stato di carica delle batterie) dal generatore.
  • Page 55: Controllo Sistema In Manuale- System In Manual Mode

    CUBE HYBRID 8,4m 4x150W LED contaore (28) indica The hour meter (28) indicates the working funzionamento dei proiettori a led, non hours of the led, it is not to be used as deve essere usato come riferimento per la reference for the periodic ordinary and periodica manutenzione ordinaria...
  • Page 56 CUBE HYBRID 8,4m 4x150W LED Quando lo Stato di Carica (SoC) delle batterie Should the State of Charge (SoC) of the scende sotto una prefissata soglia, le batterie storage battery falls at a level that requires devono essere ricaricate. L’utilizzatore deve the charging procedure, the user has to avviare manualmente...
  • Page 57: Controllo Sistema In Automatico- System In Auto Mode

    CUBE HYBRID 8,4m 4x150W LED 14.10.2.4 CONTROLLO SISTEMA IN AUTOMATICO– SYSTEM IN AUTO MODE Utilizzando logica MPnano MPnano AUTO mode is enabled when AUTO AUTOMATICO, la logica MPnano gestisce press AUTO button automaticamente la fonte di alimentazione dei enable/disable AUTO mode. MPnano, in proiettori a led.
  • Page 58: Controllo Carica Batteria Storage - Storage Battery Charging

    CUBE HYBRID 8,4m 4x150W LED 14.10.2.5 CONTROLLO CARICA BATTERIA STORAGE – STORAGE BATTERY CHARGING Pos. Descrizione Description Items Controller batterie 24 V 24 V battery monitor La procedura di carica delle batterie di storage The battery storage charging procedure is viene effettuata per mezzo di un caricabatteria controlled means...
  • Page 59 CUBE HYBRID 8,4m 4x150W LED    dedicated signal lamp always La richiesta di carica della batteria indicates the storage battery charge attivata è sempre indicato da una spia request. di segnalazione dedicata.    If a charge request is active and it is Se una richiesta di carica è...
  • Page 60 CUBE HYBRID 8,4m 4x150W LED Potenza Power La potenza in uscita dalla batteria (segno The power drawn from the battery (negative negativo) o in entrata verso la batteria sign) or flowing into the battery (positive (segno positivo). sign). Amperora consumati Consumed Amp-hours The amount of Ah consumed from the battery.
  • Page 61 CUBE HYBRID 8,4m 4x150W LED Premere nuovamente SELECT per arrestare lo Press SELECT again to stop scrolling and scorrimento e visualizzare il valore. show the value. Premere + o – per scorrere i vari valori. Press + or – to browse the various values. Premere ancora SELECT per uscire dalla Press SELECT again to leave the historical cronologia e tornare alla modalità...
  • Page 62: Efficientamento Batteria Storage - Storage Battery Efficiency Improvments

    CUBE HYBRID 8,4m 4x150W LED 14.10.2.6 EFFICIENTAMENTO BATTERIA STORAGE – STORAGE BATTERY EFFICIENCY IMPROVMENTS Sono elencate qui sotto le procedure Here after listed recommended raccomandate per garantire una maggiore procedures that have the aim to improve durata di vita delle batterie. battery life Carica subito dopo la scarica Re-charge soon after discharge...
  • Page 63: Modalita' Relè Crepuscolare - Light Sensor Mode

    CUBE HYBRID 8,4m 4x150W LED 14.11 MODALITA’ RELÈ CREPUSCOLARE – LIGHT SENSOR MODE Sull’unità è installato un relè crepuscolare che The unit provide a light sensor relay that permette di accendere spegnere i proiettori led automatically switch on/off the LEDs as in funzione della luminosità...
  • Page 64: Arresto Del Sistema - Stopping The System

    CUBE HYBRID 8,4m 4x150W LED Controllare l’interruttore (32) per l’accensione Check that the switch (32) for the ignition of delle lampade siano in posizione “ON”. the lamps are in "ON". abilitare funzionamento relè To enable the light sensor relay LEDs control, crepuscolare, posizionare il selettore LEDS put the LEDS CONTROL switch (20) on the CONTROL (20) in “LIGHT SENSOR”...
  • Page 65 CUBE HYBRID 8,4m 4x150W LED Portare il selettore SYSTEM MODE SWITCH Turn the selector SYSTEM MODE SWITCH in posizione OFF (22). in OFF position (22).   HYBRID AUTO HYBRID AUTO De-selezionare la modalità AUTO sulla logica Disable the AUTO mode on the MPnano by MPnano premendo il pulsante “AUTO”...
  • Page 66: Manutenzione Del Motore - Engine Maintenance

    CUBE HYBRID 8,4m 4x150W LED 15. MANUTENZIONE DEL MOTORE - ENGINE MAINTENANCE manutenzione motore fare For the engine maintenance refer to the riferimento al manuale specifico allegato. attached specific manual. 16. MANUTENZIONE DELLA TORRE FARO - LIGHTING TOWER MAINTENANCE È consigliata una periodica pulizia della We suggest a frequent cleaning of the macchina onde evitare depositi di sporcizia machine in order to avoid the presence of dirt...
  • Page 67: Controllo Del Cilindro Idraulico - Check Of Hydraulic Cylinder

    CUBE HYBRID 8,4m 4x150W LED 16.4 CONTROLLO DEL CILINDRO IDRAULICO – CHECK OF HYDRAULIC CYLINDER Verificare periodicamente le condizioni del Verify periodically the conditions of the cilindro idraulico di spinta, controllando che hydraulic pushing cylinder, controlling that non presenti tracce d’usura, sfregamenti, crepe there are not any usury traces, rubbing, leaks o corrosione.
  • Page 68: Principali Inconvenienti - Main Troubles

    CUBE HYBRID 8,4m 4x150W LED 17.1 PRINCIPALI INCONVENIENTI - MAIN TROUBLES ANOMALIA ANOMALY  If you eventually have any problem because Per eventuali problemi dovuti a impostazioni errate con la logica. MPnano consultare il of wrong settings of MPnano logic, please manuale “MPnano guida operatore”..
  • Page 69 CUBE HYBRID 8,4m 4x150W LED CAUSA CAUSE Vi sono dei cavi scollegati nell’impianto There are many disconnected cables in the elettrico. electrical system. RIMEDIO REMEDY Controllare visivamente l’impianto elettrico per Check visually the electrical system to find individuare i cavi scollegati (fare riferimento the disconnected cables (make reference to allo schema elettrico), eventualmente the wiring diagram), eventually contact...
  • Page 70 CUBE HYBRID 8,4m 4x150W LED ANOMALIA ANOMALY Difficoltà di avviamento del motore, rendimento The starting of the engine is difficult and there insufficiente. is a insufficient rendering. CAUSA CAUSE Filtro dell’aria sporco. The element air cleaner is dirty. RIMEDIO REMEDY Pulire l’elemento ed eventualmente sostituirlo.
  • Page 71 CUBE HYBRID 8,4m 4x150W LED ANOMALIA ANOMALY La macchina si ferma con l’indicatore luminoso The unit stops with the oil low pressure signal di bassa pressione olio acceso. lamp ignited. CAUSA CAUSE Il livello dell’olio è basso. The oil level is low. RIMEDIO REMEDY Verificare il livello e rabboccare se necessario.
  • Page 72 CUBE HYBRID 8,4m 4x150W LED ANOMALIA ANOMALY Dopo il rifornimento l’indicatore del livello After refuelling, the fuel level monitor does carburante non sale. not move. CAUSA CAUSE L’indicatore non funziona. The fuel level monitor does not work. RIMEDIO REMEDY Controllare l’indicatore e il relativo Check the fuel level monitor and its relative collegamento elettrico.
  • Page 73 CUBE HYBRID 8,4m 4x150W LED CAUSA CAUSE Collegamenti elettrici interrotti. Electrical connections interrupted. RIMEDIO REMEDY Controllare l’impianto elettrico ed Check the external electrical system and eventualmente interpellare direttamente la contact eventually GENERAC MOBILE GENERAC MOBILE PRODUCTS S.r.l. PRODUCTS S.r.l. CAUSA CAUSE Connection to Earth not correctly carried out.
  • Page 74 CUBE HYBRID 8,4m 4x150W LED GENERAC MOBILE PRODUCTS S.r.l. Via Stazione, 3 bis 27030 Villanova d’Ardenghi (PV) ITALY Tel.: +39 0382 567011 Fax:+39 0382 400247 Web site: http://www.towerlight.com E-mail: info@towerlight.com TL203-01-12-00 DISCOVER battery 16-07-2018 YANMAR ENGINE Italiano - English...