PCBs

4. PCBs
Warning
Step
1
Remove the screw, and
then the electrical box
cover.
2
Disconnect the 3
connectors from the
terminal board.
3
Remove the screw and
release the earth/
ground wire (upper).
4
Cut the 2 clamps.
10
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Procedure
Electrical box cover
(R20235)
Earth/ground wire (upper)
screw
Connector
(R23794)
Clamp
(R20238)
Si001405EB
Points
HN1 (white)
S (red)
HL1 (black)
(R23817)
Removal Procedure

Hide quick links: