Download Print this page

Thermistor Assy - Daikin RKM50PRV16 Service Manual

Advertisement

Thermistor ASSY

5. Thermistor ASSY
Warning
Step
1
Pull out the outdoor
temperature thermistor.
2
Remove the 5 screws
of the right side panel.
3
Remove the right side
panel.
4
Cut the clamp.
5
Pull out the outdoor
heat exchanger
thermistor.
12
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Procedure
Outdoor temperature thermistor
Right side panel
(R19516)
(R19517)
Clamp
Outdoor heat
exchanger
thermistor
(R20244)
Si001405EB
Points
When reassembling, pass
the outdoor temperature
thermistor through the top U-
bend of the outdoor heat
exchanger.
(R23691)
Be careful not to lose the clip
for the thermistor.
Clip
(R3264)
Removal Procedure