When the job is complete, the installer must
issue a certificate of conformity.
1 Extraction using a hood
2 Extraction without a hood
A Single natural draught chimney
B Single chimney with extractor fan
C Directly outdoors with wall- or window-
mounted extractor fan
D Directly outdoors through wall
Air
Combustion products
Extractor fan
Installation
5.2 Adaptation to different types of gas
The appliance is preset for natural
gas G20 at a pressure of 20 mbar.
In case of operation with other types of gas,
the burner nozzles must be changed and
the minimum flame adjusted on the gas
cocks.
Replacing nozzles
1. Remove the grids, burner caps and
flame-spreader crowns to access the
burner cups.
2. Replace the nozzles using a 7 mm
spanner according to the gas to be used
(see Burner and nozzle specifications
tables).
3. Replace the burners in their respective
housings.
99
Need help?
Do you have a question about the Victoria TR103GR and is the answer not in the manual?