h
CD1-3108-000
2.0mm
METAL
M1.7
2.9 LCD PANEL, BACK LIGHT UNIT
(1) LCD PANEL, BACK LIGHT UNIT
1. While taking care of the claws remove the LCD PANEL.
2. Remove the two screws of h.
3. Remove soldering (Two places) and remove the BACK LIGHT UNIT.
(1)-3
BACK LIGHT UNIT
(1)-3
Remove soldering
Fig. 3-11 LCD PANEL, BACKLIGHT UNIT
3-11
CHAPTER 3. REPAIR INSTRUCTION
NOTE (Assembling)
The BACKLIGHT UNIT that is
supplied as the service part has
the protection sheet on the back.
h
Remove it.
(1)-2
(1)-1
LCD PANEL
Claws