1. Before Starting the Repair Work

Be sure to read the following precaution before starting the repair work.

1.1 Precaution on Flash High Tension Circuit

When the OPTICAL UNIT is removed, be sure to discharge the main capacitor.
(Discharging resistor: 1 k ohms, approx. 5 W.)
First contact the GND (–) terminal of the main capacitor with the discharging resistor. Then contact the
positive (+) terminal of the main capacitor.
CAUTION:
Be careful of electric shock because the circuit is the high tension circuit.
Fig. 3-1 Precaution on flash high tension circuit

1.2 List of Supplies

The following supplies are used for the re-assembling during service.
(1) List of supplies
New
Name of supplies
DIA BOND 1663G
ADHESIVE TAPE, SONY T4000
ADHESIVE TAPE, 3M NO.56
HANARL (OIL)
CHAPTER 3. REPAIR INSTRUCTION
terminal
+
terminal
FLASH UNIT
Part No.
CY9-8129-000
CY4-6012-000
CY4-6018-000
DY9-3026-010
3-1
Areas where supplies are used
Attaching the parts together