OIL FIRED FURNACE
INSTALLER / SERVICE TECHNICIAN:
USE THE INFORMATION IN THIS MANUAL FOR THE
INSTALLATION / SERVICING OF THE FURNACE AND KEEP
THE
DOCUMENT
REFERENCE.
HOMEOWNER:
PLEASE KEEP THIS MANUAL NEAR THE FURNACE FOR
FUTURE REFERENCE.
Printed in Canada
Printed on 100% recycled paper
LOW-BOY
NEAR
THE
UNIT
Attention:
Do not tamper with the unit or its
controls. Call a qualified service
FOR
FUTURE
technician.
Manufactured by:
Dettson Industries inc.
2017-05-11
MODELS:
OLR154F20A
OLV154F20A
C
X40171 Rev. G
445 01 4301 03
US

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the OLR154F20A and is the answer not in the manual?

Questions and answers

Ruben
April 29, 2025

Burnel waring

Summary of Contents for Dettson OLR154F20A

  • Page 1 Call a qualified service DOCUMENT NEAR UNIT FUTURE technician. REFERENCE. HOMEOWNER: Manufactured by: Dettson Industries inc. PLEASE KEEP THIS MANUAL NEAR THE FURNACE FOR FUTURE REFERENCE. Printed in Canada 2017-05-11 X40171 Rev. G Printed on 100% recycled paper 445 01 4301 03...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS INDEX OF TABLES SAFETY REGULATIONS ........3 Table 1: Blower speed adjustments (heating mode, 4 SAFETY LABELING AND WARNING SIGNS ..3 speed motor) ........... 7 IMPORTANT INFORMATION ....... 3 Table 2: Blower speed adjustments (A/C mode, 4 speed DETECTION SYSTEMS ........
  • Page 3: Safety Regulations

    1 SAFETY REGULATIONS WARNING Installations and repairs performed by unqualified SAFETY LABELING AND WARNING SIGNS persons can result in hazards to them and to others. Installations must conform to local codes or, in the The words DANGER, WARNING AND CAUTION are used to absence of same, to codes of the country having identify the levels of seriousness of certain hazards.
  • Page 4: Installation

    2 INSTALLATION Figure 1: Location and dimensions of ventilation air openings in a closet door The unit is shipped with a burner and its controls. It requires a 115VAC power supply to the control panel and thermostat hook-up as shown on the wiring diagram, one or more oil line connections, suitable ductwork and connection to a properly sized vent.
  • Page 5: Installation Of The Burner

    2.4.2 Air and Turbulator Settings Figure 3: Thermostat Wiring- Heating & Air Conditioning - Before starting the burner for the first time, adjust the air With ECM Variable Speed Motor and turbulator settings to those listed in this manual. Once the burner becomes operational, final adjustments will be required.
  • Page 6: Side-Wall Venting

    such as new windows, doors, and weather stripping have 2.5.4 Side-wall venting drastically reduced the volume of air infiltration into the The heating unit is approved for side-wall venting. This system home. includes model VTK-65 / VTK-3 / KLAVT0201DET side-wall Refer to oil furnace installation codes relative to venter and a 5”...
  • Page 7: Ducting

    CAUTION Table 1: Blower speed adjustments (heating mode, 4 speed motor) When a 0.75 USGPH or smaller nozzle is used, a 10 micron or finer filter, must be installed on the oil supply line to the HEATING STATIC RECOMMENDED furnace inside the building where the unit is located. CAPACITY PRESSURE BLOWER...
  • Page 8: Installation Of Accessories

    A 24 VAC signal can also be supplied from the W and C 2.10.1 Supply air adjustment (ECM variable speed terminals on the blower electronic board to activate a motors) switching relay. On units equipped with ECM variable speed blower motors, Also refer to the instructions supplied with the accessory.
  • Page 9: Operation

    3 OPERATION 3.3.2 Pressure adjustment The oil pressure must be adjusted according to the START-UP Technical Specifications of this manual. An adjustment screw and a connection for a pressure gauge are located Before starting up the unit, be sure to check that the following on the oil pump for that purpose.
  • Page 10: Overfire Pressure Test

    CAUTION 3.3.5 Overfire pressure test The overfire draft that is taken through the observation port, Do not attempt to start the burner when excess oil has located above the burner, is a measurement necessary to accumulated, when the furnace is full of vapour or when determine if there is a blockage in the heat exchanger or the the combustion chamber is hot.
  • Page 11: Cleaning The Blocked Vent Shut-Off Device (Bvso)

    After the cleaning replace the heat exchanger baffles, flue Re-attach the assembly cover with the screws collar plate and oil burner; removed in step 2; 10. Readjust the burner for proper operation. Re-establish power to the unit. CLEANING THE BLOCKED VENT CLEANING OF THE BURNER HEAD SHUT-OFF DEVICE (BVSO) Once annually, remove the retention head and electrodes...
  • Page 12: Furnace Information

    5 FURNACE INFORMATION Model: Serial number: Furnace installation date: Service telephone #-Day: Night: Dealer name and address: START-UP RESULTS Nozzle: Pressure: lb/po Burner adjustments: Primary air Fine air Drawer Assembly Smoke scale: (Bacharach) Gross stack temperature: °F Ambient temperature: °F Chimney draft : "...
  • Page 13: Technical Specifications

    Table 7: Technical Specifications 154 LOWBOY SERIES UNITS WITH 1.0 HP 4-SP. MOTOR UNITS WITH 1.0 HP ECM MOTOR RATING AND PERFORMANCE Firing rate (USGPH)* 1.10 1.10 Input (BTU/h)* 126,000 154,000 126,000 154,000 Maximum Heating capacity, (BTU/h)* 107,000 129,000 107,000 129,000 Heating temperature rise (Degr.
  • Page 14: Airflow Data, Models With 1.0 Hp Variable Speed (Ecm) Motors

    Table 8: Airflow Data, Models with 1.0 HP variable speed (ECM) motors OIL HEATING MODE 24 VAC input (R) on W only CFM with CFM with CFM with SW1- HEAT HEAT INPUT SW3-ADJ SW3-ADJ SW3-ADJ DIP switch position (USGPH) DIP switch position A DIP switch position B DIP switch position C 0.90...
  • Page 15: Airflow Data, Models With 1.0 Hp 4 Speed Motors

    Table 9: Airflow Data, Models with 1.0 HP 4 speed motors EXTERNAL STATIC PRESSURE WITH AIR FILTER BLOWER SPEED 0.2" (W.C.) 0.3" (W.C.) 0.4" (W.C.) 0.5" (W.C.) 0.6" (W.C.) 0.7" (W.C.) HIGH 2185 2115 2045 1995 1905 1820 MED-HIGH 1900 1845 1810 1760...
  • Page 16 Figure 7: Furnace Dimensions...
  • Page 17 Figure 8: Wiring Diagram - 4 Speed Motor (PSC)
  • Page 18: Wiring Diagram - Variable Speed Motor (Ecm)

    Figure 9: Wiring Diagram - Variable Speed Motor (ECM)
  • Page 19: Parts List - With 4 Speed Motor Psc

    Figure 10: Parts List - With 4 Speed motor PSC B50095B...
  • Page 20: Parts List - With 4 Speed Motor Psc

    Table 11: Parts List - With 4 Speed motor PSC Item Part Description Comments B03775 HEAT EXCHANGER ASSEMBLY Heat exchanger only B03761 FLOOR ASSEMBLY B03746 WIRE CHANNEL, INTERIOR B03758 LOWER BLOWER DIVIDER ASSEMBLY Panel, 3 gaskets and filter rack included B03745 SIDE BAFFLE B03754-02...
  • Page 21: Parts List - With Variable Speed Motor Ecm

    Figure 11: Parts List - With variable speed motor ECM B50096C...
  • Page 22: Parts List - With Variable Speed Motor Ecm

    Table 12: Parts List - With variable speed motor ECM Item Part Description Comments B03775 HEAT EXCHANGER ASSEMBLY Heat exchanger only B03761 FLOOR ASSEMBLY B03746 WIRE CHANNEL, INTERIOR B03758 LOWER BLOWER DIVIDER ASSEMBLY Panel, 3 gaskets and filter rack included B03745 SIDE BAFFLE B03754-02...
  • Page 23 L’INSTALLATION / ENTRETIEN DE L’APPAREIL ET GARDER LE contrôles. Appeler un technicien PRÈS L’UNITÉ POUR RÉFÉRENCES DOCUMENT qualifié. ULTÉRIEURES. Fabriqué par : PROPRIÉTAIRE : Industries Dettson inc. S.V.P. GARDER MANUEL PRÈS L’UNITÉ POUR RÉFÉRENCES ULTÉRIEURES. Imprimé au Canada 2017-05-11 X40171 Rev. G Imprimé...
  • Page 24 Table des matières Index des figures Figure 1: Dimensions & localisation, ouverture de ventilation dans la porte du placard..4 ........3 RÈGLES DE SÉCURITÉ Figure 2: Branchement du thermostat-Chauffage et climatisation-Unité avec moteur 4 vitesses SIGNALISATION DANGER, MISE EN GARDE ..............
  • Page 25: Règles De Sécurité

    1 RÈGLES DE SÉCURITÉ f) Demander à l’installateur d'identifier et de vous informer sur les items suivants : L’interrupteur d’alimentation électrique ; SIGNALISATION DANGER, MISE EN La valve d’arrêt sur le réservoir de mazout ; GARDE ET AVERTISSEMENT iii) Le filtre d’huile sur le conduit (comment le changer une fois par année) ;...
  • Page 26: Risque De Gel

    RISQUE DE GEL AVERTISSEMENT Cet appareil de chauffage central n’est pas AVERTISSEMENT étanche et n’est donc pas conçu pour Si votre appareil demeure fermé durant la saison l’extérieur. L’appareil doit être installé de façon froide, les conduites d’eau peuvent geler, éclater et à...
  • Page 27: Raccordement Électrique

    Figure 3: Branchement du thermostat-Chauffage et RACCORDEMENT ÉLECTRIQUE Climatisation-Unité avec moteur ECM AVERTISSEMENT L’extérieur de l’unité doit posséder une mise à la terre ininterrompue pour minimiser les risques de blessures corporelles si jamais un problème électrique se produisait. Une vis verte de mise à la terre est incluse dans la boîte de contrôle pour effectuer cette connexion.
  • Page 28: Installation Du Brûleur

    INSTALLATION DU BRÛLEUR ÉVACUATION Veuillez vous référer aux instructions fournies par le MISE EN GARDE fabriquant du brûleur pour plus de détails. Positionner le joint d’étanchéité entre la plaque de Risque d’empoisonnement par monoxyde de montage de l’unité et la bride du brûleur. Aligner les carbone.
  • Page 29: Cheminée

    2.5.4 Évacuation directe murale APPROVISIONNEMENT EN AIR L’unité de chauffage est approuvée avec un système DE COMBUSTION ET d’évacuation directe murale. Ce système comprend un évacuateur mural modèle VTK-65 VTK-3 VENTILATION KLAFVT0201DET et un tuyau d’évacuation isolé de 5’’ de MISE EN GARDE diamètre modèle IFV-5 / KLAFVxx01DET.
  • Page 30: Réservoir De Mazout

    Exposition à ces agents chimiques : SYSTÈME DE DISTRIBUTION Solutions pour cheveux ; D’AIR Cires et nettoyants à base de chlore ; MISE EN GARDE Agents chimiques pour piscine à base de chlore ; Agents chimiques adoucisseur d’eau ; Risque d’intoxication au monoxyde de carbone. Sels ou agents chimiques pour le déglaçage ;...
  • Page 31: Ventilation (Moteur 4 Vitesses)

    Table 2: Ajustement des vitesses de ventilation (Mode Table 3: Ajustements débit d'air - Mode chauffage climatisation, moteur 4 vitesses) SW1 – HEAT (Chauffage) Puissance Position interrupteurs DIP CAPACITÉ DE VITESSE DE USGPH CLIMATISATION VENTILATION POSITION 0.90 (USGPH) RECOMMENDÉE 1.10 MED-LOW MED-HIGH Table 4:...
  • Page 32: Opération

    (LIGNE) à la borne EAC. Cette dernière fonctionne 2.12.1 Humidificateur (HUM) pendant toute demande chaleur Le terminal HUM – 120 VAC sur le contrôle électronique du refroidissement, et la soufflerie fonctionnera jusqu’à ventilateur est relié directement au terminal #8 du l’installation d’un nouveau moteur ECM.
  • Page 33: Vérifications Et Ajustements

    La demande de chauffe est satisfaite. La valve Ajuster la quantité d’air pour obtenir une lecture solénoïde ferme et le moteur du brûleur s’arrête du CO de 1.5% de moins (ou O de 2% de (après le délai post purge, si applicable) plus) que la lecture correspondant à...
  • Page 34: Entretien

    3.3.7 Test de hausse de température 4 ENTRETIEN Faire fonctionner le brûleur pendant au moins 10 minutes ; MISE EN GARDE Mesurer la température de l’air dans le plénum de retour d’air ; Risque de décharge électrique Mesurer la température de l’air au plus large Avant d’effectuer travaux...
  • Page 35: Nettoyage Du Dispositif D'arrêt Anti-Refoulement (Bvso)

    Nettoyer les différentes parties de l’échangeur à l’aide Remettre l’alimentation électrique. d’une brosse rigide et d’un aspirateur; Avant le réassemblage, inspecter l’échangeur de NETTOYAGE DE LA TÊTE DU chaleur et la chambre de combustion afin de BRÛLEUR déterminer leurs états; Une fois par année, retirer l’assemblage de la ligne Après le nettoyage, replacer les déflecteurs, la bride d’huile et des électrodes du brûleur.
  • Page 36 5 FICHE TECHNIQUE DE L’APPAREIL Modèle: Numéro de série: Date d’installation de la fournaise: Numéros de téléphone Jour: Soir: Nom et adresse du technicien de service: RÉSULTAT DU TEST DE MISE EN MARCHE Gicleur: Pression: lb/po Ajustements du brûleur: Bande principale Bande secondaire Position de la tête Indice de fumée:...
  • Page 37 Table 7: Spécifications techniques SÉRIE LOWBOY 154 UNITÉS AVEC MOTEUR 1.0 HP 4-VIT. UNITÉS AVEC MOTEUR 1.0 HP ECM TAUX ET PERFORMANCE Allure de chauffe (USGPH)* 1.10 1.10 Input (BTU/h)* 126,000 154,000 126,000 154,000 Puissance de chauffage maximum (BTU/h)* 107,000 129,000 107,000 129,000...
  • Page 38: Climatisation

    Table 8: Débit d'air, unité avec moteur 1.0 HP ECM MODE DE CHAUFFAGE AU MAZOUT Signal 24 VAC (R) sur W seulement PCM avec SW1- Chauffage Puisssance PCM avec interrupteur PCM avec interrupteur interrupteur Position Chauffage DIP "SW3-ADJ", DIP "SW3-ADJ", DIP "SW3-ADJ", interrupteurs DIP (USGPH)
  • Page 39: Combustibles

    Table 9: Débit d'air (PCM), unité avec moteur 1.0 HP PRESSION STATIQUE EXTERNE AVEC FILTRE À AIR VITESSE 0.2" (C.E.) 0.3" (C.E.) 0.4" (C.E.) 0.5" (C.E.) 0.6" (C.E.) 0.7" (C.E.) 2185 2115 2045 1995 1905 1820 HIGH 1900 1845 1810 1760 1685 1635...
  • Page 40 Figure 7: Dimensions de la fournaise...
  • Page 41 Figure 8: Diagramme électrique - Moteur 4 vitesses (PSC) ____________________________________________________________________________________...
  • Page 42 Figure 9: Diagramme électrique - Moteur vitesse variable (ECM)
  • Page 43 Figure 10: Liste de pièces - Avec moteur 4 vitesses (PSC) B50095B ____________________________________________________________________________________...
  • Page 44 Table 11: Liste de pièces - Avec moteur PSC Item Numéro Description Commentaires B03775 ASS ÉCHANGEUR CHÂLEUR Échangeur seulement B03761 ASSEMBLAGE PLANCHER B03746 CACHE FIL INTÉRIEUR B03758 ASSEMBLAGE SÉPARATEUR BAS Comprend panneau, 3 bandes et support à filtre B03745 DÉFLECTEUR LATÉRAL B03754-02 ASSEMBLAGE PANNEAU CÔTÉ...
  • Page 45 Figure 11: Liste de pièces - Avec moteur vitesse variable (ECM) B50096C ____________________________________________________________________________________...
  • Page 46 Table 12: Liste de pièces - Avec moteur vitesse variable (ECM) Item Numéro Description Commentaires B03775 ASS ÉCHANGEUR CHÂLEUR Échangeur seulement B03761 ASSEMBLAGE PLANCHER B03746 CACHE FIL INTÉRIEUR B03758 ASSEMBLAGE SÉPARATEUR BAS Comprend panneau, 3 bandes et support à filtre B03745 DÉFLECTEUR LATÉRAL B03754-02...