Dettson AMT100B34-SM1 Installation Instructions Manual

Oil fired furnace low-boy
Table of Contents

Advertisement

Available languages

Available languages

OIL FIRED FURNACE
INSTALLER / SERVICE TECHNICIAN:
USE THE INFORMATION IN THIS MANUAL FOR THE INSTALLATION AND
SERVICING OF THE FURNACE. KEEP THE DOCUMENT NEAR THE UNIT FOR
FUTURE REFERENCE.
HOMEOWNER:
PLEASE KEEP THIS MANUAL NEAR THE FURNACE FOR FUTURE
REFERENCE.
Printed in Canada
Printed on 100% recycled paper
LOW-BOY
DNS-0537 Rev B
AMT
AMT-S
AMiT
AMT-I
2011-09-21
Models:
AMT100B34-SM1
AMT100B34-IM2
AMT200B34-SM3
AMT200B34-IM2
C
US
Caution : Do not tamper with the
unit or its controls.
Call a qualified service technician.
Manufactured by:
Dettson Industries inc.
3400 Industrial Boulevard
Sherbrooke, Quebec – Canada - J1L 1V8
www.dettson.ca
X40004 Rev. AC
(AMiT)
(AMiT)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AMT100B34-SM1 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Dettson AMT100B34-SM1

  • Page 1 USE THE INFORMATION IN THIS MANUAL FOR THE INSTALLATION AND SERVICING OF THE FURNACE. KEEP THE DOCUMENT NEAR THE UNIT FOR Manufactured by: FUTURE REFERENCE. Dettson Industries inc. HOMEOWNER: 3400 Industrial Boulevard Sherbrooke, Quebec – Canada - J1L 1V8 PLEASE KEEP THIS MANUAL NEAR THE FURNACE FOR FUTURE www.dettson.ca...
  • Page 2: Table Of Contents

    FIGURES TABLE OF CONTENTS Figure 1: Fan-limit adjustment and blower regulator ....8 PART 1 INSTALLATION ..........3 Figure 2: Model AMT1-1M2 ............13 1.1) DANGER, WARNING AND CAUTION......3 Figure 3: Model AMT1-SM1............13 1.2) SAFETY INSTALLATION REQUIREMENTS ....3 Figure 4: Model AMT2-IM2 ............14 Figure 5: Model AMT2-SM3............14 1.3) GENERAL ................
  • Page 3: Part 1 Installation

    PART 1 INSTALLATION FOR YOUR SAFETY CAUTION ENVIRONMENTAL HAZARD – Failure to follow DO NOT STORE OR USE GASOLINE OR OTHER this caution may result in environmental pollution. FLAMMABLE VAPORS LIQUIDS Remove and recycle all components or materials VICINITY OF THIS OR ANY OTHER APPLIANCE. (i.e.
  • Page 4: General

    1.3) GENERAL Table 1: Minimum ventilation openings dimensions required in a closet or enclosure This furnace is a Low-Boy unit and may be operated in an upflow configuration only. Input Width Height It is shipped as a packaged unit, complete with burner and controls. It (BTU/h) requires a line voltage (115 VAC) connection to the control box, a 75,000 –...
  • Page 5: 1.4.2) Duct Recommendations

    1.4.2) Duct recommendations This inspection should include the following: Inspection for any deterioration in the chimney or vent. If The proper sizing of warm air ducts is necessary to ensure deterioration is discovered, the chimney must be repaired or satisfactory furnace operation. Ductwork should be in accordance the vent must be replaced;...
  • Page 6: 1.4.6) Electrical

    When installing optional accessories on this appliance, follow the CAUTION manufacturer’s installation instructions included with the accessory. Other than wiring for the thermostat, wire with a minimum of type “T” NEVER use the “interrupted ignition” function if a insulation (17 C rise (63 F)) must be used for accessories.
  • Page 7: Part 2 Operation

    PART 2 OPERATION The CO and flue temperature instruments will enable you to 2.1) OPERATIONAL CHECKLIST obtain the data that are required to determine the terminal efficiency of the furnace. Although this information is good to 1=> Is the electrical wiring completed according to have, it is not essential in the basic set up of the furnace.
  • Page 8: Limit Control Check

    2.4) LIMIT CONTROL CHECK Figure 1: Fan-limit adjustment and blower regulator The Limit Control is factory adjusted according to Figure 1.. After the furnace has been in operation for at least 15 minutes, restrict the return air supply by blocking the filters or closing the return registers and allow the furnace to shut down on high limit.
  • Page 9: Part 3 Maintenance

    PART 3 MAINTENANCE 3.2) BLOWER REMOVAL This furnace should never be operated without an air filter. Disposable filters should be replaced at least once a year. If equipped to provide cooling, filters should be replaced a minimum of To remove the blower from the furnace: twice a year.
  • Page 10: Part 4 Information

    PART 4 INFORMATION Model: Serial number: Furnace installation date: Service telephone # - Day: Night: Dealer name and address: START-UP TEST RESULTS Nozzle: Pressure: lb/psi Burner adjustments: Primary air Fine air Drawer Assembly Smoke scale: (Bacharach) °F Gross flue temperature: Ambient temperature: °F Chimney draft:...
  • Page 11: Table 3: Technical Specifications For Models Amt1/Amt2

    Table 3: Technical specifications for models AMT1/AMT2 (with 3/4 motor) Models: AMT1 and AMT2 RATING AND PERFORMANCE Firing rate (USGPH) 0.50 0.65 0.75 0.85 1.00 1,10 Input (BTU/h) 70 000 91 000 105 000 119 000 140 000 154 000 Heating capacity (BTU/h) 57 000 74 000...
  • Page 12: Table 5: Air Delivery - Cfm With Air Filter

    Table 5: Air delivery - CFM with air filter AMT75 to AMT105 (1/3 HP MOTOR) SPEED EXTERNAL STATIC PRESSURE WITH AIR FILTER 0.2" (W.C.) 0.3" (W.C.) 0.4" (W.C.) 0.5" (W.C.) 1425 1350 1305 1250 HIGH 1130 1045 1000 MED-HIGH MED-LOW AMT120 to AMT155 (3/4 HP MOTOR) SPEED EXTERNAL STATIC PRESSURE WITH AIR FILTER...
  • Page 13: Figure 2: Model Amt1-1M2

    Figure 2: Model AMT1-IM2 Figure 3: Model AMT1-SM1...
  • Page 14: Figure 4: Model Amt2-Im2

    Figure 4: Model AMT2-IM2 Figure 5: Model AMT2-SM3...
  • Page 15: Figure 6: Wiring Diagram Amt1-Im2 And Amt2-Im2

    Figure 6: Wiring diagram AMT1-IM2 and AMT2-IM2...
  • Page 16: Figure 7: Wiring Diagram Amt1-Sm1 And Amt2-Sm3, Heating Only

    Figure 7: Wiring diagram AMT1-SM1 and AMT2-SM3, heating only...
  • Page 17: Figure 8: Wiring Diagram Mt1-Sm1 And Amt2-Sm3, Heating And Optional Cooling

    Figure 8: Wiring diagram MT1-SM1 and AMT2-SM3, heating and optional cooling...
  • Page 18: Figure 9: Parts List - Amt1-Im2

    Figure 9: Parts list - AMT1-IM2 B50054B...
  • Page 19: Table 7: Parts List - Amt1-1M2

    Table 7: Parts list - AMT1-IM2 ITEM DESCCRIPTION COMMENTS PART # HEAT EXCHANGER ASSEMBLY Heat exchanger only B01701 FLOOR BAFFLE B01708 BOTTOM DIVIDER ASSEMBLY Panel and 3 gaskets included B01725 DD BLOWER SUPPORT B01724 BAFFLE B01707 PANEL ASSEMBLY, LEFT SIDE Panel, insulation, baffle and filter rack included B03197-03 INSULATION, LEFT SIDE PANEL...
  • Page 20: Figure 10: Parts List - Amt1-Sm1

    Figure 10: Parts list - AMT1-SM1 B50055B...
  • Page 21: Table 8: Parts List - Amt1-Sm1

    Table 8: parts list - AMT1-SM1 ITEM DESCRIPTION COMMENTS PART # HEA T EX CHA NG ER A SSEM BLY Heat exchanger only B01701-01 FLO O R BA FFLE B01708 BO TTO M DIV IDER A SSEM BLY Panel and 3 gaskets included B01725 DD BLO W ER SUPPO RT B01724...
  • Page 22: Figure 11: Parts List - Amt2-Sm3

    Figure 11: Parts list - AMT2-SM3 B50056B...
  • Page 23: Table 9: Parts List - Amt2-Sm3

    Table 9: Parts list - AMT2-SM3 ITEM DESCRIPTION COMMENTS PART # HEAT EXCHANGER ASSEMBLY Heat exchanger only B01741 FLOOR BAFFLE B01708 BOTTOM DIVIDER ASSEMBLY Panel and 3 gaskets included B01831 DD BLOWER SUPPORT B01756 LATERAL BAFFLE B01750 PANEL ASSEMBLY, LEFT SIDE Panel, insulation, baffle and filter rack included B03205-02 INSULATION, LEFT SIDE PANEL...
  • Page 24: Figure 12: Parts List - Amt2-Im2

    Figure 12: Parts list - AMT2-IM2 B50057C...
  • Page 25: Motor)

    Table 10: Parts list - AMT2-IM2 ITEM DESCRIPTION COMMENTS No DESSIN HEAT EXCHANGER ASSEMBLY Heat exchanger only B01741 FLOOR BAFFLE B01708 BOTTOM DIVIDER ASSEMBLY Panel and 3 gaskets included B01764 DD BLOWER SUPPORT B01756 LATERAL BAFFLE B01750 PANEL ASSEMBLY, LEFT SIDE Panel, insulation, baffle and filter rack included B03204-02 INSULATION, LEFT SIDE PANEL...
  • Page 26 UTILISER LES RENSEIGNEMENTS DANS CE MANUEL POUR L’INSTALLATION ET L’ENTRETIEN DE L’APPAREIL. GARDER LE DOCUMENT PRÈS DE L’UNITÉ Fabriqué par : POUR RÉFÉRENCES ULTÉRIEURES. Industries Dettson inc. PROPRIÉTAIRE : 3400, boulevard Industriel Sherbrooke, Québec – Canada - J1L 1V8 S.V.P. GARDEZ CE MANUEL PRÈS DE L’UNITÉ POUR RÉFÉRENCES www.dettson.ca...
  • Page 27 TABLE DE MATIÈRES FIGURES Figure 1: Ajustement du limiteur et régulateur de ventilateur combiné SECTION 1 INSTALLATION .......... 2 ..................7 Figure 2: Modèle AMT1-IM2............12 1.1) DANGER, MISE EN GARDE ET AVERTISSEMENT ..2 Figure 3: Modèle AMT1-SM1 ............12 1.2) RECOMMENDATIONS POUR UNE INSTALLATION SÉCURITAIRE..............
  • Page 28: Section 1 Installation

    SECTION 1 INSTALLATION MISE EN GARDE POUR VOTRE SÉCURITÉ NE PAS ENTREPOSER OU UTILISER D’ESSENCE, Ne jamais faire brûler de déchets ou de papier DE LIQUIDES OU DE VAPEURS INFLAMMABLES À dans le système de chauffage. Ne jamais laisser PROXIMITÉ DE CET APPAREIL OU DE TOUT de chiffons ou de papier à...
  • Page 29: Généralités

    1.3) GÉNÉRALITÉS Tableau 1: Dimensions minimales requises pour les ouvertures de ventilation Cet appareil de chauffage central est de type LOW-BOY et fonctionne en débit ascendant (Upflow) seulement. Consommation Longueur Hauteur (BTU/h) L’unité est expédiée avec le brûleur et les contrôles. Elle requiert un circuit électrique (115 VAC) connecté...
  • Page 30: Recommandations Pour Les Conduits

    Pour des informations supplémentaires sur l’évacuation, se référer à 1.4.2 Recommandations pour les conduits ANSI/NFPA 211 Cheminées, foyers, évents et appareils de chauffage combustible solide et/ou B139 Code Pour assurer un fonctionnement satisfaisant de l’appareil de d’installation. chauffage central, il est nécessaire que la dimension des conduits soit adéquate.
  • Page 31: Instructions D'évacuation (Système De Combustion Scellé)

    Cheminées fabriquées en usine AVERTISSEMENT Il est possible d’utiliser les cheminées fabriquées en usine qui sont L’extérieur de l’unité doit posséder une mise à la terre homologuées. Se référer aux instructions du manufacturier de ininterrompue pour minimiser les risques de blessures cheminées pour une installation adéquate.
  • Page 32: Dispositif D'arrêt Anti-Refoulement (Bvso) Pour Évacuation Par Cheminée

    1.5) Dispositif d’arrêt Pour l’installation et le câblage électrique veuillez-vous référer aux diagrammes électriques de l’unité et aux instructions détaillées anti-refoulement (BVSO) Pour évacuation par fourni avec le Dispositif d’arrêt anti-refoulement. Pour que le câblage cheminée électrique fourni avec l’unité soit suffisamment long, il est important que le dispositif d’arrêt soit installé...
  • Page 33: Vérification De L'ajustement Du Ventilateur7

    moteur à entraînement direct du ventilateur doivent être changées Un filtre au mazout 10 microns (ou moins) devrait être installé pour obtenir le débit d’air de refroidissement requis. aussi près que possible du brûleur dans le cas de tous les brûleurs au mazout et est essentiel avec les brûleurs à...
  • Page 34: Section 3 Entretien

    SECTION 3 ENTRETIEN Ne jamais faire fonctionner l’appareil de chauffage central sans filtre à air. Les filtres jetables devraient être remplacés au moins une fois 3.2) DÉMONTAGE DU VENTILATEUR par année. Si l’appareil de chauffage central est équipé pour la climatisation, les filtres devraient être remplacés au moins deux fois Pour sortir le ventilateur de l’appareil de chauffage central : par année.
  • Page 35: Section 4 Information

    SECTION 4 INFORMATION Numéro de série : Modèle : Date d’installation de la fournaise : Nos. tél. service – Jour : Soir : Nom et adresse du technicien de service : RÉSULTAT DU TEST DE MISE EN MARCHE Gicleur : Pression : lb/po Ajustements du brûleur :...
  • Page 36: Tableau 3: Spécifications Techniques Amt1 Et Amt2

    Tableau 3: Spécifications techniques AMT1 et AMT2 (avec moteur 3/4 HP) Modèles : AMT1, AMT2 TAUX ET PERFORMANCE Allure de chauffe (USGPH) 0.50 0.65 0.75 0.85 1.00 1.10 Consommation (BTU/h) 70000 91000 105000 119000 140000 154000 Puissance de chauffage (BTU/h) 57000 74000 85000...
  • Page 37: Tableau 5: Débit D'air - Pcm Avec Filtre À Air

    Tableau 5: Débits d'air - PCM avec filtre à air AMT75 À AMT105 (MOTEUR 1/3 HP) VITESSE PRESSION STATIQUE EXTERNE AVEC FILTRE À AIR 0.2" (C.E.) 0.3" (C.E.) 0.4" (C.E.) 0.5" (C.E.) HIGH 1425 1350 1305 1250 1130 1045 1000 MED-HIGH MED-LOW AMT120 À...
  • Page 38 Figure 2: Modèle AMT1-IM2 Figure 3: Modèle AMT1-SM1...
  • Page 39 Figure 4: Modèle AMT2-IM2 Figure 5: Modèle AMT2-SM3...
  • Page 40 Figure 6: Diagramme électrique: AMT1-IM2 et AMT2-IM2...
  • Page 41 Figure 7: Diagramme électrique AMT1-SM1 et AMT2-SM3, chauffage seulement...
  • Page 42 Figure 8: Diagramme électrique: AMT1-SM1 et AMT2-SM3, chauffage et option climatisation...
  • Page 43 Figure 9: Liste de pièces, modèle AMT1-IM2 B50054B...
  • Page 44: Tableau 7: Liste De Pièces, Modèle Amt1-Im2

    B50054B Tableau 7: Liste de pièces, modèle AMT1-IM2 ITEM DESCRIPTION COMMENTAIRES No DESSIN ASS ECHANGEUR CHALEUR Échangeur seulement B01701 DEFLECTEUR DE PLANCHER B01708 ASS SEPARATEUR BAS Comprend panneau et 3 bandes B01725 SUPPORT DE VENTILATEUR DD B01724 DEFLECTEUR B01707 ASS PANNEAU COTE GAUCHE Comprend panneau, isolation, déflecteur et support à...
  • Page 45 Figure 10: Liste de pièces, modèle AMT1-SM1 B50055B...
  • Page 46: Tableau 8: Liste De Pièces, Modèle Amt1-Sm1

    Tableau 8: Liste de pièces, modèle AMT1-SM1 ITE M D E SC R IPTIO N C O M M E N TA IR E S N o D E SSIN A SS ECHA NG EUR CHA LEUR Échangeur seulement B01701-01 DEFLECTEUR DE PLA NCHER B01708 A SS SEPA RA TEUR BA S...
  • Page 47 Figure 11: Liste de pièces, modèle AMT2-SM3 B50056B...
  • Page 48: Tableau 9: Liste De Pièces, Modèle Amt2-Sm3

    Tableau 9: Liste de pièces, modèle AMT2-SM3 ITE M D E S C R IP T IO N CO M M E N TA IR E N o D E S S IN ASS ECH ANG EU R C HALEU R Échan geur seulem e nt B0174 1 DEFLECTEU R D E PLANC HER...
  • Page 49 Figure 12: Liste de pièces, modèle AMT2-IM2 B50057C B50057C...
  • Page 50: Tableau 10: Liste De Pièces, Modèle Amt2-Im2

    Tableau 10: Liste de pièces, modèle AMT2-IM2 ITEM DESCRIPTION COMMENTAIRES No DESSIN B50057D ASS ECHANGEUR CHALEUR Échangeur seulement B01741 DEFLECTEUR DE PLANCHER B01708 ASS SEPARATEUR BAS Comprend panneau et 3 bandes B01764 SUPPORT DE VENTILATEUR DD B01756 DEFLECTEUR LATERAL B01750 ASS PANNEAU COTE GAUCHE Comprend panneau, isolation, déflecteur et support à...

This manual is also suitable for:

Amt200b34-im2Amt100b34-im2Amt200b34-sm3

Table of Contents