Dettson AMT400B34-SM1PMA Installation Instructions And Homeowner's Manual

Warm air furnace oil fired - upflow
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

WARM AIR FURNACE
OIL FIRED - UPFLOW
DNS-0836 REV.B
INSTALLER / SERVICE TECHNICIAN:
USE THE INFORMATION IN THIS MANUAL FOR THE
INSTALLATION / SERVICING OF THE FURNACE AND KEEP
THE
DOCUMENT
REFERENCE.
HOMEOWNER:
PLEASE KEEP THIS MANUAL NEAR THE FURNACE FOR
FUTURE REFERENCE.
Printed in Canada
Printed on 100% recycled paper
NEAR
THE
UNIT
2011-05-30
MODELS:
AMT400B34-SM1PMA
OLR350H28B
Attention:
Do not tamper with the unit or its
controls. Call a qualified service
FOR
FUTURE
technician.
Manufactured by:
Dettson Industries inc.
3400 Industrial Boulevard
Sherbrooke, Qc – Canada J1L 1V8
X40096 Rev. I

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AMT400B34-SM1PMA and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Dettson AMT400B34-SM1PMA

  • Page 1 DOCUMENT NEAR UNIT FUTURE technician. REFERENCE. HOMEOWNER: Manufactured by: Dettson Industries inc. PLEASE KEEP THIS MANUAL NEAR THE FURNACE FOR 3400 Industrial Boulevard FUTURE REFERENCE. Sherbrooke, Qc – Canada J1L 1V8 Printed in Canada 2011-05-30 X40096 Rev. I Printed on 100% recycled paper...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS SAFETY REGULATIONS..............................4 SAFETY LABELING AND WARNING SIGNS ......................4 IMPORTANT INFORMATION ............................4 DETECTION SYSTEMS ..............................4 DANGER OF FREEZING ..............................4 INSTALLATION ..................................5 POSITIONING THE FURNACE............................5 ELECTRICAL SYSTEM ..............................5 INSTALLATION OF THE BURNER..........................5 2.3.1 Nozzles ..................................
  • Page 3 ABLE ABLE 3: T ABLE ECHNICAL PECIFICATIONS 4: A - CFM ABLE ELIVERY WITH ILTER 5 - M – - CANADA ABLE INIMUM CLEARANCES COMBUSTIBLE MATERIALS 6 - M – -USA ABLE INIMUM CLEARANCES COMBUSTIBLE MATERIALS 7 - P ABLE ARTS IGURE IGURE...
  • Page 4: Safety Regulations

    Before calling for service, be sure to have the information page of your manual close by in order 1 SAFETY REGULATIONS to be able to provide the contractor with the required information, such as the model and serial numbers of the furnace. SAFETY LABELING AND WARNING SIGNS WARNING...
  • Page 5: Installation

    ELECTRICAL SYSTEM 2 INSTALLATION CAUTION The unit is shipped with a burner and its controls. It requires a The exterior of the unit must have an uninterrupted ground 115VAC power supply to the control panel and thermostat to minimize the risk of bodily harm, if ever an electrical hook-up as shown on the wiring diagram, one or more oil line problem develops.
  • Page 6: Venting

    efer to the detailed instructions and wiring diagrams VENTING supplied with the BVSO for the installation and wiring procedures. The length of wires supplied with the unit is WARNING such that the safety device must be installed between the flue outlet of the appliance and the draft regulator, as indicated in the instructions.
  • Page 7: Contaminated Combustion Air

    A manual shut-off valve and an oil filter shall be installed 2.6.1 ONTAMINATED OMBUSTION in sequence from tank to burner. Be sure that the oil line is Installations in certain areas or types of structures will increase clean before connecting to the burner. The oil line should the exposure to chemicals or halogens that may harm the protected eliminate...
  • Page 8: Operation

    SEQUENCE OF OPERATION WARNING BECKETT AFG / RIELLO 40-F Poisonous carbon monoxide gas hazard. Normally open contact (T-T) on primary relay closed when thermostat calls for heat; Install the evaporator coil on the supply side of the furnace ducting ONLY. Beckett burner: The motor starts and spark is established.
  • Page 9: Combustion Check

    3.3.3 OMBUSTION HECK 3.3.6 EMPERATURE IMPORTANT After having adjusted the burner combustion, insert a The heat exchanger metal surfaces may have oil and the thermometer into the test hole in the breech pipe; baffle insulation also contains binders. These products will The total vent temperature should be between 204 burn or evaporate when the unit operates for the first time.
  • Page 10: Fan Limit Adjustment

    3.3.9 UPPLY EMPERATURE To decrease the airflow, loosen setscrew on the inner half of the motor pulley, looking at the shaft end. Turn the Operate the burner for at least 10 minutes; inner half of the pulley clockwise. After the adjustment, Measure the air temperature in the return air plenum;...
  • Page 11: Maintenance

    CLEANING THE BLOCKED VENT 4 MAINTENANCE SHUT-OFF DEVICE (BVSO) WARNING For continuous safe operation, the Blocked Vent Shut-off device (BVSO) must be inspected and maintained annually by a qualified service technician. Electrical shock hazard. Disconnect power to the appliance; Turn OFF power and fuel to the furnace before any Remove the two screws holding on the BVSO disassembly or servicing.
  • Page 12: Motor Lubrication

    MOTOR LUBRICATION Belt tension verification Do NOT lubricate the oil burner motor or the direct drive deally, belt tension should be checked with an appropriate blower motor as they are permanently lubricated. gauge. If such a tool is not available, the tension can be checked by applying pressure to it in the centre between the pulleys.
  • Page 13: Furnace Information

    5 FURNACE INFORMATION Model: Serial number: Furnace installation date: Service telephone #-Day: Night: Dealer name and address: START-UP RESULTS Nozzle: Pressure: lb/po Burner adjustments: Primary air Fine air Drawer Assembly Smoke scale: (Bacharach) Gross stack temperature: °F Ambient temperature: °F Chimney draft : "...
  • Page 14 23 7/8" x 25 7/8" ou 23 7/8" x 29 3/4" Return air duct W x L 23 7/8" x 25 3/4" Maximum cooling capacity 8 tons AMT400B34-SM1PMA – OLR350H28B Table 4: Air Delivery - CFM with Air Filter MODEL INPUT (USGPH) EXTERNAL STATIC PRESSURE 0.25"...
  • Page 15 Table 5 - Minimum clearances – combustible materials - CANADA CLEARANCE RECOMMENDED ACCESS LOCATION APPLICATION (combustible materials) FOR SERVICE Left or right 0.6 m (24") Sides Left or right 0.25 mm (9") Back Access panel to blower 0.6 m (24") 0.9 m (36") Furnace or plenum 0.15 m (6”)
  • Page 16 Figure 5 - Furnace dimensions DNS-0848 Rev. E...
  • Page 17 Figure 6 - Ladder Diagram, Heating and Cooling AMT400B34-SM1PMA / OLR350H28B...
  • Page 18 Figure 7 - Wiring Diagram, heating and cooling AMT400B34-SM1PMA / OLR350H28B DNS-1016 Rev. B...
  • Page 19 Figure 8 - Wiring Diagram, Heating AMT400B34-SM1PMA / OLR350H289B DNS-1021 Rev. B...
  • Page 20 COMPONENTS REPLACEMENT PARTS...
  • Page 21 Figure 9 - Parts List With 4-speed motor PSC B50043B...
  • Page 22 Table 7 - Parts List ITEM PART # DESCRIPTION B02840 Heat exchanger B02866 Top divider B02838 Clamping plate B02839 Top divider gasket B02867 Front top divider 3" B03344 Right filter support B02853-05 Panel assembly, rear, side B02877-01 Insulation, front panel B02875-01 Baffle, right lateral B02854-01...
  • Page 23 L’INSTALLATION / ENTRETIEN DE L’APPAREIL ET GARDER LE contrôles. Appeler un technicien DOCUMENT PRÈS L’UNITÉ POUR RÉFÉRENCES qualifié. ULTÉRIEURES. PROPRIÉTAIRE : Fabriqué par : Industries Dettson inc. S.V.P. GARDER MANUEL PRÈS L’UNITÉ POUR 3400 boulevard Industriel RÉFÉRENCES ULTÉRIEURES. Sherbrooke, Qc – Canada J1L 1V8 Imprimé...
  • Page 24 Table des matières RÈGLES DE SÉCURITÉ............................4 SIGNALISATION DANGER, MISE EN GARDE ET AVERTISSEMENT............ 4 REMARQUES IMPORTANTES........................4 SYSTÈMES DE PROTECTION........................4 RISQUE DE GEL.............................. 5 INSTALLATION ..............................5 EMPLACEMENT ............................. 5 É ..........................6 RACCORDEMENT LECTRIQUE INSTALLATION DU BRÛLEUR........................6 2.3.1 Gicleurs ..............................
  • Page 25 Table des figures et tableaux 1 - A ........................11 IGURE JUSTEMENT DE LA POULIE ......................11 IGURE AJUSTEMENT DE LA HAUTE LIMITE .......................... 13 IGURE ALIGNEMENT DES POULIES 4 - V ..................13 IGURE ÉRIFICATION DE LA TENSION DE LA COURROIE 5 - D HMT4 ............................
  • Page 26: Règles De Sécurité

    f) Demander à l’installateur d'identifier et de 1 RÈGLES DE SÉCURITÉ vous informer sur les items suivants : L’interrupteur d’alimentation électrique ; La valve d’arrêt sur le réservoir de SIGNALISATION DANGER, MISE EN mazout ; GARDE ET AVERTISSEMENT iii) Le filtre d’huile sur le conduit (comment le changer une fois par année) ;...
  • Page 27: Risque De Gel

    RISQUE DE GEL AVERTISSEMENT Cet appareil de chauffage central n’est pas AVERTISSEMENT étanche et n’est donc pas conçu pour Si votre appareil demeure fermé durant la saison l’extérieur. L’appareil doit être installé de façon froide, les conduits d’eau peuvent geler, éclater et à...
  • Page 28: Raccordement Électrique

    Pour sélectionner le calibre du gicleur, toujours RACCORDEMENT ÉLECTRIQUE calculer le débit désiré à la pression réelle et déduire le calibre équivalent. AVERTISSEMENT 2.3.2 Réglage de l’air et du turbulateur L’extérieur de l’unité doit posséder une mise à la terre ininterrompue pour minimiser les risques de blessures Avant de démarrer le brûleur pour la première fois, corporelles si jamais un problème électrique se...
  • Page 29: Régulateur De Tirage

    APPROVISIONNEMENT EN AIR 2.4.3 Régulateur de tirage DE COMBUSTION ET VENTILATION Cette unité peut être installé avec ou sans régulateur barométrique. Il est cependant recommandé d’installer un MISE EN GARDE régulateur barométrique sur les installations avec un tirage de cheminée élevé, ou avec un tirage variant avec les Risque d’empoisonnement par monoxyde de conditions extérieures.
  • Page 30: Brûleur - Air De Combustion Extérieur

    Exposition à ces agents chimiques : SYSTÈME DE DISTRIBUTION Solutions pour cheveux ; D’AIR Cires et nettoyants à base de chlore ; MISE EN GARDE Agents chimiques pour piscine à base de chlore ; Agents chimiques adoucisseur d’eau ; Risque d’intoxication au monoxyde de carbone. Sels ou agents chimiques pour le déglaçage ;...
  • Page 31: Opération

    le cycle de l’air de combustion. Durant ce Un espace minimum de 15 cm (6") est requis entre le temps, la pression retenue par la valve dessous du serpentin de climatisation et le dessus de solénoïde est d’environ 100 psig. La valve l’échangeur de chaleur.
  • Page 32: Vérification De La Combustion

    3.3.3 Vérification de la combustion 3.3.5 Test de pression dessus feu La pression au-dessus de la flamme, mesurée à la IMPORTANT fenêtre d'observation (située au centre, au dessus Les surfaces métalliques de l’échangeur peuvent du brûleur, dans le panneau avant de l'appareil de chauffage central), est requise pour déterminer s'il y contenir de l’huile et l’isolation des déflecteurs a un blocage dans l'échangeur de chaleur ou le...
  • Page 33: Ajustement Du Limiteur

    Table 1 - Ajustement du ventilateur Figure 2 - ajustement de la haute limite AMT-245 /280 AMT-315 /350 Débit d’air approximatif 3100 3500 du ventilateur (CFM) Ajustement de la poulie du moteur (nombre de tour) - Avec une pression statique de 0.25" W.C. Table 2 - ajustement de la poulie AMT-245 /280 AMT-315 /350...
  • Page 34: Démarrage Après Défaillance Du Brûleur

    démarrage du brûleur dépend aussi, dans ce cas, de recommandé de faire vérifier votre unité par un l’ajustement du délai « OFF » du ventilateur. technicien qualifié avant chaque saison de chauffage afin déterminer nettoyage 3.3.11 Démarrage après défaillance remplacement de certaines composantes est requis. du brûleur Si un nettoyage est nécessaire, les étapes suivantes devraient être effectuées :...
  • Page 35: Nettoyage De La Tête Du Brûleur

    Remettre en place le couvercle de l’ensemble avec les vis enlevées à l’étape 2 ; Remettre l’alimentation électrique. 4.7.2 Remplacement de la courroie NETTOYAGE DE LA TÊTE DU Vérifier l’usure de la courroie du ventilateur et BRÛLEUR remplacer celle-ci si nécessaire. À...
  • Page 36: Fiche Technique De L'appareil

    5 Fiche technique de l'appareil Modèle : Numéro de série : Date d’installation de la fournaise : Nos tél. service – Jour : Soir : Nom et adresse du technicien de service : RÉSULTAT DU TEST DE MISE EN MARCHE Gicleur : Pression : lb/po...
  • Page 37 Table 3 - Spécifications techniques AMT400B34-SM1PMA – OLR350H28B TAUX ET PERFORMANCE Allure de chauffe (USGPH) 1.75 2.00 2.25 2.50 Consommation (BTU/h) 245 000 280 000 315 000 350 000 Puissance de chauffage (BTU/h) 215 300 241 600 270 900 297 000 Hausse de température de chauffge...
  • Page 38 Table 5 - Dégagements minimums - matériaux combustibles - CANADA DÉGAGEMENT ACCÈS RECOMMANDÉ EMPLACEMENT APPLICATION (matériaux combustibles) POUR L’ENTRETIEN Gauche ou droit 0.6 m (24") CÔTÉS Gauche ou droit 0.25 m (9") ARRIÈRE Porte d’accès au ventilateur 0.6 m (24") 0.9 m (36") Fournaise et plénum 0.15 m (6")
  • Page 39 Figure 5 - Dimension HMT4 DNS-0848 Rév. E ____________________________________________________________________________________...
  • Page 40 Figure 6 - Diagramme en échelle, chauffage et climatisation AMT400B34-SM1PMA / OLR350H28B...
  • Page 41 Figure 7 - Diagramme électrique, chauffage et climatisation AMT400B34-SM1PMA – OLR350H28 DNS-1016 Rev.B ____________________________________________________________________________________...
  • Page 42 Figure 8 - Diagramme électrique, chauffage AMT400B34-SM1PMA – OLR350H28 DNS-1021 Rev.B...
  • Page 43 COMPOSANTES PIÈCES DE REMPLACEMENT ____________________________________________________________________________________...
  • Page 44 Figure 9 - Liste de pièces (avec moteur 4 vitesses - PSC) B50043 Rev.B...
  • Page 45 Table 7 - Liste de pièces (Avec moteur 4 vitesses PSC) ITEM # PIÈCE DESCRIPTION B02840 ASS ECHANGEUR CHALEUR B02866 DIVISEUR HAUT ARRIERE B02838 PLAQUE DE SERRAGE B02839 GARNITURE DIVISEUR HAUT B02867 DIVISEUR HAUT AVANT 3" B03344 SUPPORT DE FILTRE DROIT B02853-05 ASS PANNEAU COTE ARRIERE B02877-01...

This manual is also suitable for:

Olr350h28b