Installation And House Coding - Ei Electronics Ei603 Instructions Manual

Battery powered smoke & heat alarms
Hide thumbs Also See for Ei603:
Table of Contents

Advertisement

Installation and House Coding

To fit the Ei600MRF module, plug it into the base of the compatible Alarm while
being careful to align the pins and insert the flexible antenna into the antenna hole
(See Fig 1). N.B. Ensure that the Ei600MRF is fully inserted.
Figure 1
Check to ensure all RF devices have been successfully House Coded. This can
be done by counting the number of blue flashes on each RF Module. The number
of flashes should correspond to the number of RF devices in the system. (i.e. 4
flashes if there are 4 RF devices in the system).
www.acornfiresecurity.com
House Coding the Unit
Power supply to the Ei600MRF will be confirmed
by an initial flash of the red, blue and green LED
on the cover (see Fig 2).
Press and hold the House Code button on the
module until the blue light illuminates on the
cover. (see Fig 2).
Immediately release the button, the blue light will
flash rapidly and then stop. Now attach the Alarm
to its mounting plate. (see 'Installation' section in
the Ei650 Series booklet).
The flashing will repeat every 5 seconds
thereafter. Repeat this procedure for all RF
devices in the system.
5
www.acornfiresecurity.com

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ei605Ei600 seriesEi605crf

Table of Contents