Kelvinator 18000Btu/h Installation Manual page 9

Inverter split - type room air conditioner
Table of Contents

Advertisement

INSTALLATION
3.
Connecting
Pipe and Drainage Installation
1. Run the drain hose sloping downward. Do not install the drain hose as illustrated below.
Do not block water flow with a rise.
2. When connecting an extension drain hose, insulate the connecting part of the extension
drain hose with a shield pipe, do not let the drain hose become slack.
Connecting pipe
1. For the left-hand and right-hand piping, remove the pipe cover from the side panel.
2. For the rear-right-hand and rear-left-hand piping, install the piping as shown. Bend the
c
onnecting
pipe to be laid at a height of 43mm or less from the wall.
3. Fix the end of the c
PIPING CONNECTION)
Right-hand piping
Left-hand piping
Side Part cover
Fig.8
4. Indoor unit installation
1. Pass the piping through the hole in the wall.
2. Put the upper claw at the back of the indoor unit on
the upper hook of the installation plate, move the
indoor unit from side to side to see that it is securely
hooked.
3. Piping can easily be made by lifting the indoor unit
with a cushioning material between the indoor unit
and the wall. Remove cushioning material after finish
piping.
4. Push the lower part of the indoor unit up on the wall,
Then move the indoor unit from side to side, up and
down to check if it is hooked securely.
Fig.7
onnecting
pipe. (Refer to Tightening Connection in REFRIGERANT
Rear-right piping
Rear-left piping
Do not put the end of the
drain hose into water.
Indoor unit outline
8
C
onnecting
pipe
.
Fig.9
Upper Hook
Lower Hook
Cushioning
material
Fig.10