NH 2100T
3.8 Operating Environment
Power Requirements
115 Vac ±10% 3.0A
230 Vac ±10% 1.5A
Power Connections
The NH 2100T ATM must be connected to a dedicated power circuit. This circuit must
consist of LINE, NEUTRAL and GROUND leads connected directly to the power circuit
breaker panel. This circuit cannot be shared with any other equipment.
Phone Line Requirements
The NH 2100T ATM must be connected to a dedicated phone line. This line must be a
direct dial "tone" or "pulse" line that is equipped with a standard telephone wall jack (RJ-
11). This line cannot be shared with any other equipment at the location.
Temperature
In storage
While operating : 40°F - 95°F (5°C ~ 35°C)
Humidity
In storage
While operating : 25% < RH < 85%, Non-Condensed
60Hz , 350 Watt
50Hz , 350 Watt
: 32°F - 123°F (0°C ~ 49°C)
: 10% < RH < 90%, Non-Condensed
3- 10
3. Hardware Specifications