Adjusting X And Y Sensors (Instant Adjustment) - Bernina Deco 330 Operation, Service Manual & Parts List

Hide thumbs Also See for Deco 330:
Table of Contents

Advertisement

Deco 330
Adjusting X and Y Sensors (Simple Adjustment)
To adjust X and Y sensor (without removing the base unit):
2
7
1
Y
3
4
X
5
6
5
8
1 Remove the base cover.
2 Remove the presser foot holder and place the fabric
on the Embroidery hoop (A).
Attach the Embroidery hoop (A) on the carriage.
(Place the Template 2 on the Embroidery hoop as
shown.)
3 Turn the power switch "ON" and select the pattern No.1
on the touch panel.
4
Check that the Needle 3 goes into the Hole 4 in
the Template 2 .
5 Turn the power switch "OFF".
6 If the needle drop position is slightly out of position
in the Y-direction, loosen the screw (A) 1 and move
the Y-sensor fixing plate 8 to adjust.
If the needle drop position is slightly out of position in
the X direction, loosen Screw (B) 5 through the
hole of the Sheet cover fixing plate hole
the X shield plate
7 Turn the power switch "ON".
Select the pattern No.1 on the touch panel, then check
if the needle goes into the center of the hole in the
Template 4 .
8 Return the carriage to the stored position, then turn
the power switch "OFF".
9 Remove the Template 2 and Embroidery hoop then
install the base cover.
1
Screw (A)
2
Template
3
Needle
4
Hole in the template
5
Screw (B)
6
X-shield plate
7
Hole of the sheet cover fixing plate
8
Y-Sensor fixing plate
9
Y-direction
X-direction
10
27
7
6
to adjust.