GSM REMOTE SWITCH GRG-01
DESCRIPTION
GSM remote switch is used to control
lighting, heating, etc., by means of GSM
mobile (SMS massage and/or incoming
mobile call). It is mounted in wall 230 V
AC socket and it has the possibility of
a remote restart of a connected device
(relay status changes according to the ad-
justed time). The device has a wide range
of protections as a list of numbers with
permission, access password, etc. Its op-
eration range is limited only by GSM net-
work infrastructure and it is not equipped
with operator's lock (SIMLOCK).
FEATURES
● remote control of electric device opera-
tion by means of commands (incoming
voice call, SMS massages) send from
a mobile phone,
● comfortable control of devices with dif-
ficult access (ventilation, heating, other),
● three operation modes (switching on,
switching off, restart - contact relay po-
sition change for adjusted time),
● easy mounting in 230V AC socket,
● operation is optically signalled (power
supply, relay status, GSM modem status),
● low power consumption, possibility of
constant work.
The device is designed for
single-phase
installation
and must be installed in
accordance with standards
valid in a particular country.
The device should be con-
CAUTION!
nected according to the de-
tails included in this operat-
ing manual. Installation, connection and control
should be carried out by a qualified electrician
staff, who act in accordance with the service
manual and the device functions.
In case of casing dismantling an electric shock
may occur, and the guarantee is lost then. Be-
fore installation make sure the connection ca-
bles are not under voltage. The cruciform head
screwdriver 3,5 mm should be used to instal the
device. Improper transport, storage, and use of
the device influence its wrong functioning. It is
not advisable to instal the device in the following
cases: if any device part is missing or the device
is damaged or deformed. In case of improper
functioning of the device contact the producer.
The symbol means selective
collecting of electrical and electronic
equipment. It is forbidden to put the
used equipment together with
other waste.
ZAMEL Sp. z o.o.
ul. Zielona 27, 43-200 Pszczyna, Poland
tel. +48 (32) 210 46 65, fax +48 (32) 210 80 04
www.zamelcet.com, e-mail: marketing@zamel.pl
TECHNICAL DATA
Input rated voltage: 230 V AC
Optic signalling of input rated voltage: LED green diode
Nominal power consumption: 0,5 W / 2,5 W (GSM operation)
GSM frequency: 900/1800/1900 MHz
Operation range: limited by GSM network structure
Signalling of GSM status: LED two-coloured diode (green)
Optic signalling of relay status: LED two-coloured diode (red)
Output contacts' parameters: 1NO 16A / 250V AC AC1 4000 VA
Ambient temperature range: -10 ÷ +55
Operating position: free
Casing mounting: 230 V AC socket
Casing protection degree: IP20 (EN 60529)
Protection level: II
Overvoltage category: II
Pollution degree: 2
Surge voltage: 1 kV (EN 61000-4-5)
Dimensions: 160 x 66 x 90 mm
Weight: 0,190 kg
Reference standard: EN 60950-1:2007
APPEARANCE
SIM
card
INSTRUCTION MANUAL
GRG-01
C
o
EN 55024:2000
EN 61000-4-4
Optic signalling of input voltage
Optic signalling of GSM network
Receiver's switch on optic signal (red)
Manual operation of the receiver
Programming push-button
SIM card socket
Receiver's socket
Power supply pin
status (green)
Hole plug
VER. 002_01.06.2011

Advertisement

loading

Summary of Contents for Zamel Exta free GRG-01

  • Page 1 GSM REMOTE SWITCH GRG-01 INSTRUCTION MANUAL ZAMEL Sp. z o.o. ul. Zielona 27, 43-200 Pszczyna, Poland tel. +48 (32) 210 46 65, fax +48 (32) 210 80 04 www.zamelcet.com, e-mail: marketing@zamel.pl DESCRIPTION TECHNICAL DATA GSM remote switch is used to control GRG-01 lighting, heating, etc., by means of GSM...
  • Page 2 In order to activate GRG-01 device it is necessary to prepare SIM card without PIN or with PIN 1111. In order to instal SIM card it is necessary to remove ZAMEL hole plug by means of a screwdriver. The hole plug must be slightly levered from the left.
  • Page 3 Power Management IC Development Tools Click to view products by manufacturer: Zamel Other Similar products are found below : EVAL6482H-DISC EVAL-AD5522EBUZ EVAL-ADM1060EBZ EVAL-ADM1073MEBZ EVAL-ADM1166TQEBZ EVAL- ADM1168LQEBZ EVAL-ADM1171EBZ EVAL-ADM1276EBZ EVB-EN5319QI EVB-EN5365QI EVB-EN6347QI EVB-EP5348UI MIC23158YML EV MIC23451-AAAYFL EV MIC5281YMME EV ADM00513 ADM8611-EVALZ ADM8612-EVALZ ADM8613- EVALZ ADM8615-EVALZ ADP1046ADC1-EVALZ ADP1055-EVALZ ADP122-3.3-EVALZ ADP130-0.8-EVALZ ADP130-1.2-EVALZ...