Fusing Temperature Control 2
A1: Normal warm-up (SP1103-1 = 0, default)
A2: Idling during warm-up (SP1103-1 = 1, good for cold temp starts)
T1: Low power temp (SP1105-7, default is 60°C)
T2: Stand-by temp (SP1105-3, default is 175°C)
T4: Print/copy temp (SP1105-5, default is 175°C)
G: Fusing temp check timing (SP1108, default is 1 s)
Slide 106
Normally leave SP1103-1 at 0. Set SP1103-1 to 1 if fusing quality is low just after
warm-up. Warm-up will take longer but fusing quality will be better.
T4 for thick paper is set by SP1105-9.
T2 default for this machine is the same as T4 (
Generally leave SP1108 alone. If room lights flicker when the fusing lamp comes
on, you can set a larger value.
However, if you set SP1108 to 2 (3 seconds), the BICU may not be able to
detect fusing lamp errors.
175°C).