Cisco Nexus 9332D-GX2B Hardware Installation Manual

Cisco Nexus 9332D-GX2B Hardware Installation Manual

Nx-os mode switch
Hide thumbs Also See for Nexus 9332D-GX2B:

Advertisement

Quick Links

Cisco Nexus 9332D-GX2B NX-OS Mode Switch Hardware Installation
Guide
First Published: 2021-10-18
Last Modified: 2021-12-13
Americas Headquarters
Cisco Systems, Inc.
170 West Tasman Drive
San Jose, CA 95134-1706
USA
http://www.cisco.com
Tel: 408 526-4000
800 553-NETS (6387)
Fax: 408 527-0883

Advertisement

Table of Contents
loading

Summary of Contents for Cisco Nexus 9332D-GX2B

  • Page 1 Cisco Nexus 9332D-GX2B NX-OS Mode Switch Hardware Installation Guide First Published: 2021-10-18 Last Modified: 2021-12-13 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 http://www.cisco.com Tel: 408 526-4000 800 553-NETS (6387) Fax: 408 527-0883...
  • Page 2 Any products and features described herein as in development or available at a future date remain in varying stages of development and will be offered on a when-and if-available basis. Any such product or feature roadmaps are subject to change at the sole discretion of Cisco and Cisco will have no liability for delay in the delivery or failure to deliver any products or feature roadmap items that may be set forth in this document.
  • Page 3: Table Of Contents

    Installing the Chassis Safety Installation Options with Rack-Mount Kits Airflow Considerations Installation Guidelines Unpacking and Inspecting the Switch Installing the Switch Using the NXK-ACC-KIT-1RU Rack-Mount Kit Grounding the Chassis Starting the Switch Cisco Nexus 9332D-GX2B NX-OS Mode Switch Hardware Installation Guide...
  • Page 4 Switch and Module Weights and Quantities Transceiver and Cable Specifications Switch Power Input Requirements Power Specifications 1500-W AC Power Supply Specifications Power Cable Specifications Power Cables for NXA-PAC-1500W Power Supplies Regulatory Standards Compliance Specifications Cisco Nexus 9332D-GX2B NX-OS Mode Switch Hardware Installation Guide...
  • Page 5 A P P E N D I X C LEDs Switch Chassis LEDs Fan Module LEDs Power Supply LEDs A P P E N D I X D Additional Kits Rack Mount Kit NXK-ACC-KIT-1RU Cisco Nexus 9332D-GX2B NX-OS Mode Switch Hardware Installation Guide...
  • Page 6 Contents Cisco Nexus 9332D-GX2B NX-OS Mode Switch Hardware Installation Guide...
  • Page 7: Overview

    Overview • Overview, on page 1 Overview The Cisco Nexus 9332D-GX2B switch (N9K-C9332D-GX2B) is a 1-rack unit (RU), fixed-port switch designed for deployment in data centers. This switch includes the following ports: • 400-Gigabit QSFP-DD ports (32) • 10-Gigabit SFP+ ports (2) •...
  • Page 8 1 (left) and 2 (right) Fan modules (6) with slots Management port (SFP) numbered from 1 (left) to 6 (right) Console port USB port The following figure shows the side of the chassis. Cisco Nexus 9332D-GX2B NX-OS Mode Switch Hardware Installation Guide...
  • Page 9 If the switch has port-side exhaust airflow (blue coloring for fan modules), you must locate the ports in the hot aisle. If you locate the air intake in a hot aisle, the switch can overheat and shut down. Cisco Nexus 9332D-GX2B NX-OS Mode Switch Hardware Installation Guide...
  • Page 10 Overview Overview Cisco Nexus 9332D-GX2B NX-OS Mode Switch Hardware Installation Guide...
  • Page 11: Preparing The Site

    Altitude Requirements Altitude rating is based on power supply installed; see critical components list in the system CB report for altitude rating. Cisco Nexus 9332D-GX2B NX-OS Mode Switch Hardware Installation Guide...
  • Page 12: Dust And Particulate Requirements

    The wiring is unlikely to emit radio interference if you use a twisted-pair cable with a good distribution of grounding conductors. If you exceed the recommended distances, use a high-quality twisted-pair cable with one ground conductor for each data signal when applicable. Cisco Nexus 9332D-GX2B NX-OS Mode Switch Hardware Installation Guide...
  • Page 13: Shock And Vibration Requirements

    The surfaces shall be cleaned and an antioxidant applied before installation. Planning for Power Requirements The switch includes two power supplies (1-to-1 redundancy with current sharing) in one of the following combinations: • Two 1500-W AC power supplies Cisco Nexus 9332D-GX2B NX-OS Mode Switch Hardware Installation Guide...
  • Page 14: Airflow Requirements

    The switch is positioned with its ports in either the front or the rear of the rack depending on your cabling and maintenance requirements. You must have fan and power supply modules that move the coolant air from the cold aisle to the hot aisle in one of the following ways: Cisco Nexus 9332D-GX2B NX-OS Mode Switch Hardware Installation Guide...
  • Page 15: Rack And Cabinet Requirements

    Statement 1048 Rack Stabilization The rack stabilizing mechanism must be in place, or the rack must be bolted to the floor before installation or servicing. Failure to stabilize the rack can cause bodily injury. Cisco Nexus 9332D-GX2B NX-OS Mode Switch Hardware Installation Guide...
  • Page 16: Clearance Requirements

    19.0 in (43.3 cm) Note Both the front and rear of the chassis must be open to both aisles for airflow. Cisco Nexus 9332D-GX2B NX-OS Mode Switch Hardware Installation Guide...
  • Page 17: Installing The Chassis

    Starting the Switch, on page 19 Safety Before you install, operate, or service the switch, see the Regulatory, Compliance, and Safety Information for the Cisco Nexus 3000 and 9000 Series for important Safety Information. Warning Statement 1071 Warning Definition IMPORTANT SAFETY INSTRUCTIONS Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents.
  • Page 18: Installation Options With Rack-Mount Kits

    You can install the switch using the following rack-mount options: • Rack-mount kit (NXK-ACC-KIT-1RU) which you can order from Cisco. This option offers you easy installation, greater stability, increased weight capacity, added accessibility, and improved removability with front and rear removal.
  • Page 19 This product relies on the building's installation for short-circuit (overcurrent) protection. Ensure that the protective devices is rated not greater than 40A for the regular DC power supplies (rated 48-60VDC) and 10A for the HVDC power supplies. Cisco Nexus 9332D-GX2B NX-OS Mode Switch Hardware Installation Guide...
  • Page 20: Unpacking And Inspecting The Switch

    You must supply the eight 10-32 or 12-24 screws required to mount the slider rails and switch to the rack. Before you begin • You have inspected the switch shipment to ensure that you have everything ordered. Cisco Nexus 9332D-GX2B NX-OS Mode Switch Hardware Installation Guide...
  • Page 21 The holes that you use depend on the requirements of your rack and the amount of clearance required for interface cables (3 inches [7.6 mm] minimum) and module handles (1 inch [2.5 mm] minimum). Cisco Nexus 9332D-GX2B NX-OS Mode Switch Hardware Installation Guide...
  • Page 22 Holding the switch with both hands, position the two rear rack-mount brackets on the switch between the rack or cabinet posts that do not have slider rails attached to them (see the following figure). Cisco Nexus 9332D-GX2B NX-OS Mode Switch Hardware Installation Guide...
  • Page 23 Tighten the 10-32 screws to 20 in-lb (2.26 N·m) or tighten the 12-24 screws to 30 in-lb (3.39 N·m). Step 5 If you attached a grounding wire to the chassis grounding pad, connect the other end of the wire to the facility ground. Cisco Nexus 9332D-GX2B NX-OS Mode Switch Hardware Installation Guide...
  • Page 24: Grounding The Chassis

    Verify that the ground wire is securely attached to the grounding lug by attempting to pull the wire out of the crimped lug. Cisco Nexus 9332D-GX2B NX-OS Mode Switch Hardware Installation Guide...
  • Page 25: Starting The Switch

    • The rack must be close enough to the dedicated power source so that you can connect the switch to the power source by using a designated power cables. • You have the designated power cables for the power supplies that you are connecting to the dedicated power sources. Cisco Nexus 9332D-GX2B NX-OS Mode Switch Hardware Installation Guide...
  • Page 26 If there is a safety cover for the terminals, place and secure it over the terminals to avoid an electrical shock hazard. e) Turn on the power at the circuit breaker for the DC power source. Step 4 Verify that the power supply LED is on and green. Cisco Nexus 9332D-GX2B NX-OS Mode Switch Hardware Installation Guide...
  • Page 27 A setup utility automatically launches the first time that you access the switch and guides you through the basic configuration. For instructions on how to configure the switch and check module connectivity, see the appropriate Cisco Nexus 9000 Series configuration guide.
  • Page 28 Installing the Chassis Starting the Switch Cisco Nexus 9332D-GX2B NX-OS Mode Switch Hardware Installation Guide...
  • Page 29 When running cables in overhead or subfloor cable trays, we strongly recommend that you locate power cables and other potential noise sources as far away as practical from network cabling that terminates on Cisco equipment. In situations where long parallel cable runs cannot be separated by at least 3.3 feet (1 meter), we recommend that you shield any potential noise sources by housing them in a grounded metallic conduit.
  • Page 30 Connect the other end of the RJ-45 rollover cable to the console or to a modem. What to do next You are ready to create the initial switch configuration (see Creating the Initial Switch Configuration, on page 25). Cisco Nexus 9332D-GX2B NX-OS Mode Switch Hardware Installation Guide...
  • Page 31 To connect the switch to the network, you can use the default choices for each configuration except the IP address, which you must provide. You can perform the other configurations later as described in the Cisco Nexus 9000 Series NX-OS Fundamentals Configuration Guide.
  • Page 32 RJ-45 connectors. For longer connections, you can use an optical cable with SFP transceivers (LH or SX type). Note Use only one of these management ports—the switch does not support the use of both management ports. Cisco Nexus 9332D-GX2B NX-OS Mode Switch Hardware Installation Guide...
  • Page 33 When removing transceivers from the switch, it is best to remove the optical cable first and then remove the transceiver. To determine which transceivers, adapters, and cables are supported by this switch, see the Cisco Transceiver Modules Compatibility Information document. Cisco Nexus 9332D-GX2B NX-OS Mode Switch Hardware Installation Guide...
  • Page 34 Connecting the Switch to the Network Connecting Interface Ports to Other Devices Cisco Nexus 9332D-GX2B NX-OS Mode Switch Hardware Installation Guide...
  • Page 35 On the fan module that you are removing, press the two sides of the fan module handle next to where it connects to the fan module and pull on the handles enough to unseat it from its connectors. Step 2 Holding the handle, pull the module out of the chassis. Cisco Nexus 9332D-GX2B NX-OS Mode Switch Hardware Installation Guide...
  • Page 36 • Ensure that the chassis is grounded. For grounding instructions, see Grounding the Chassis, on page Cisco Nexus 9332D-GX2B NX-OS Mode Switch Hardware Installation Guide...
  • Page 37 Note If the power supply does not fit into the open slot, turn the module over before sliding it carefully into the open slot. Cisco Nexus 9332D-GX2B NX-OS Mode Switch Hardware Installation Guide...
  • Page 38 Depending on the outlet receptacle on your power distribution unit, you might need the optional jumper cable to connect the switch to your outlet receptacle. Step 5 Verify that the power supply is operational by making sure that the power supply LED is green. Cisco Nexus 9332D-GX2B NX-OS Mode Switch Hardware Installation Guide...
  • Page 39 • Standard 19-inch (48.3 cm) (two- or four-post EIA cabinet or rack, with mounting rails that conform to English universal hole spacing per section 1 of ANSI/EIA-310-D-1992). For more information, see Requirements Specific to Perforated Cabinets, on page Cisco Nexus 9332D-GX2B NX-OS Mode Switch Hardware Installation Guide...
  • Page 40 To help with cable management, you might want to allow additional space in the rack above and below the chassis to make it easier to route all of the fiber optic or copper cables through the rack. Cisco Nexus 9332D-GX2B NX-OS Mode Switch Hardware Installation Guide...
  • Page 41: Environmental Specifications

    Altitude rating is based on power supply installed; see critical components list in the system CB report for altitude rating. Switch Dimensions Switch Width Depth Height Cisco Nexus 9332D-GX2B 17.3 inches (43.9 cm) 22.9 in (58.1 cm) 1.72 inches (4.4 cm) (1 RU) Cisco Nexus 9332D-GX2B NX-OS Mode Switch Hardware Installation Guide...
  • Page 42: Switch And Module Weights And Quantities

    Consumption (AC or DC) Consumption (AC or DC) Requirement Cisco Nexus 638 W 1442 W 4,920.308 BTUs 9332D-GX2B Power Specifications Power specifications include the specifications for each type of power supply module. Cisco Nexus 9332D-GX2B NX-OS Mode Switch Hardware Installation Guide...
  • Page 43: Power Cable Specifications

    Japan 250V AC Type A Power Cable CAB-TA-EU Europe AC Type A Power Cable CAB-C15-CBN Cabinet Jumper Power Cord, 250 VAC 13A, C14-C15 Connectors CAB-ACBZ-12A AC Power Cord (Brazil) 12A/125V BR-3-20 plug up to 12A Cisco Nexus 9332D-GX2B NX-OS Mode Switch Hardware Installation Guide...
  • Page 44: Regulatory Standards Compliance Specifications

    • AS/NZS CISPR22 Class A • CISPR22 Class A • EN55022 Class A • ICES003 Class A • VCCI Class A • EN61000-3-2 • EN61000-3-3 • KN22 Class A • CNS13438 Class A Cisco Nexus 9332D-GX2B NX-OS Mode Switch Hardware Installation Guide...
  • Page 45 Specification Description EMC: Immunity • EN55024 • CISPR24 • EN300386 • KN 61000-4 series RoHS The product is RoH-6 compliant with exceptions for leaded-ball grid-array (BGA) balls and lead press-fit connectors. Cisco Nexus 9332D-GX2B NX-OS Mode Switch Hardware Installation Guide...
  • Page 46 System Specifications System Specifications Cisco Nexus 9332D-GX2B NX-OS Mode Switch Hardware Installation Guide...
  • Page 47 Temperature exceeds the major alarm threshold. The switch is not receiving power. Green Fans and power supply modules are operational. Amber At least one fan or power supply module is not operating. Cisco Nexus 9332D-GX2B NX-OS Mode Switch Hardware Installation Guide...
  • Page 48 Power supply is not receiving power. Green Flashing amber Power supply warning—possibly one of the following conditions: • High voltage • High power • Low voltage • Slow power supply fan Cisco Nexus 9332D-GX2B NX-OS Mode Switch Hardware Installation Guide...
  • Page 49 Hazardous substances list for customers in China The following table lists and illustrates the console cable (CAB-CONSOLE-RJ45) that can be ordered. Illustration Description Quantity Console cable with DB-9F and RJ-45F connectors Cisco Nexus 9332D-GX2B NX-OS Mode Switch Hardware Installation Guide...
  • Page 50 Additional Kits Additional Kits Cisco Nexus 9332D-GX2B NX-OS Mode Switch Hardware Installation Guide...

This manual is also suitable for:

N9k-c9332d-gx2b

Table of Contents