Cisco N9K-C9332PQ Hardware Installation Manual

Cisco N9K-C9332PQ Hardware Installation Manual

Aci-mode switch
Hide thumbs Also See for N9K-C9332PQ:
Table of Contents

Advertisement

Quick Links

Cisco Nexus 9332PQ ACI-Mode Switch Hardware Installation Guide
First Published: 2015-08-04
Last Modified: 2019-03-28
Americas Headquarters
Cisco Systems, Inc.
170 West Tasman Drive
San Jose, CA 95134-1706
USA
http://www.cisco.com
Tel: 408 526-4000
800 553-NETS (6387)
Fax: 408 527-0883

Advertisement

Table of Contents
loading

Summary of Contents for Cisco N9K-C9332PQ

  • Page 1 Cisco Nexus 9332PQ ACI-Mode Switch Hardware Installation Guide First Published: 2015-08-04 Last Modified: 2019-03-28 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 http://www.cisco.com Tel: 408 526-4000 800 553-NETS (6387) Fax: 408 527-0883...
  • Page 2 Cisco and the Cisco logo are trademarks or registered trademarks of Cisco and/or its affiliates in the U.S. and other countries. To view a list of Cisco trademarks, go to this URL: https://www.cisco.com/c/en/us/about/legal/trademarks.html. Third-party trademarks mentioned are the property of their respective owners. The use of the word partner does not imply a partnership relationship between Cisco and any other company.
  • Page 3: Table Of Contents

    Minimizing Electromagnetic and Radio Frequency Interference Shock and Vibration Requirements Grounding Requirements Planning for Power Requirements Airflow Requirements Rack and Cabinet Requirements Clearance Requirements C H A P T E R 3 Installing the Switch Chassis Cisco Nexus 9332PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 4 Replacing a Power Supply Module Replacing an AC Power Supply Replacing a DC Power Supply A P P E N D I X A Rack Specifications Overview of Racks General Requirements for Cabinets and Racks Cisco Nexus 9332PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 5 A P P E N D I X D Additional Kits Rack Mount Kit NXK-ACC-KIT-1RU Rack Mount Kit N3K-C3064-ACC-KIT A P P E N D I X E Site Preparation and Maintenance Records Site Preparation Checklist Contact and Site Information Cisco Nexus 9332PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 6 Contents Chassis and Module Information Cisco Nexus 9332PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 7: Preface

    Braces and a vertical bar within square brackets indicate a required choice within an optional element. Indicates a variable for which you supply values, in context where italics variable cannot be used. Cisco Nexus 9332PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 8: Related Documentation

    Downloadable Documentation • Knowledge Base Articles (KB Articles)are available at the following URL: https://www .cisco.com/c/en/us/support/cloud-systems-management/application-policy-infrastructure-controller-apic/products-configuration-examples-list.html • Cisco Application Centric Infrastructure Controller Release Notes • Cisco Application Centric Infrastructure Fundamentals Guide • Cisco APIC Getting Started Guide • Cisco ACI Virtualization Guide •...
  • Page 9 • Cisco ACI System Messages Reference Guide • Cisco APIC Layer 4 to Layer 7 Services Deployment Guide • Cisco APIC Layer 4 to Layer 7 Device Package Development Guide • Cisco APIC Layer 4 to Layer 7 Device Package Test Guide •...
  • Page 10: Documentation Feedback

    What's New in Cisco Product Documentation, at: https://www.cisco.com/warp/public/687/Directory/DirTAC.shtml. Subscribe to What's New in Cisco Product Documentation, which lists all new and revised Cisco technical documentation as an RSS feed and delivers content directly to your desktop using a reader application. The RSS feeds are a free service.
  • Page 11: Overview

    Overview, on page 1 Overview The Cisco Nexus 9332PQ switch (N9K-C9332PQ) is a 1 rack unit (RU) switch that supports 26 40-Gigabit QSFP+ downlink ports (ports 1 to 12 and 15 to 26 support the Dynamic Breakout cabling), 6 40-Gigabit QSFP+ uplink ports, one 100/1000 network management ports, one RS-232 console port for setting the initial switch configuration, and two USB ports for saving or loading switch configurations.
  • Page 12 Power supply modules (1 or 2) (AC power supply shown) with Console port (1) slots numbered from 1 (left) to 4 (right). Fan modules (4) with slots numbered 1 (left) and 2 (right). Grounding pad Cisco Nexus 9332PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 13 If the switch has port-side exhaust airflow (blue coloring for fan modules), you must locate the ports in the hot aisle. If you locate the air intake in a hot aisle, the switch can overheat and shut down. Cisco Nexus 9332PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 14 Overview Overview Cisco Nexus 9332PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 15: Preparing The Site

    Altitude Requirements Altitude rating is based on power supply installed; see critical components list in the system CB report for altitude rating. Cisco Nexus 9332PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 16: Dust And Particulate Requirements

    The wiring is unlikely to emit radio interference if you use a twisted-pair cable with a good distribution of grounding conductors. If you exceed the recommended distances, use a high-quality twisted-pair cable with one ground conductor for each data signal when applicable. Cisco Nexus 9332PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 17: Shock And Vibration Requirements

    For n+1 redundancy, you can use one or two power sources for the two power supplies. For n+n redundancy, you must use two power sources and connect each power supply to a separate power source. Cisco Nexus 9332PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 18 Connect the unit only to DC power source that complies with the Safety Extra-Low Voltage (SELV) requirements in IEC 60950 based safety standards. Note We recommend 8-AWG wire for DC installations in the U.S. Cisco Nexus 9332PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 19: Airflow Requirements

    Work with your cabinet vendors to determine which of their cabinets meet the following requirements or see the Cisco Technical Assistance Center (TAC) for recommendations: • Use a standard 19-inch (48.3-cm), four-post Electronic Industries Alliance (EIA) cabinet or rack with mounting rails that conform to English universal hole spacing per section 1 of the ANSI/EIA-310-D-1992 standard.
  • Page 20: Clearance Requirements

    For the clearances required for an installation of this chassis in a four-post rack, see the following figure. Chassis Depth of the chassis Vertical rack-mount posts and rails Maximum extension of the bottom-support rails Cisco Nexus 9332PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 21 Width of the front clearance area (equal to the width of the chassis with two rack-mount brackets that are attached to it). Note Both the front and rear of the chassis must be open to both aisles for airflow. Cisco Nexus 9332PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 22 Preparing the Site Clearance Requirements Cisco Nexus 9332PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 23: Safety

    Starting the Switch, on page 27 Safety Before you install, operate, or service the switch, see the Regulatory, Compliance, and Safety Information for the Cisco Nexus 3000 and 9000 Series for important Safety Information. Warning Statement 1071 Warning Definition IMPORTANT SAFETY INSTRUCTIONS This warning symbol means danger.
  • Page 24: Installation Options With Rack-Mount Kits, Racks, And Cabinets

    You can install the switch using the following rack-mount options: • Rack-mount kit (NXK-ACC-KIT-1RU) which you can order from Cisco. This option offers you easy installation, greater stability, increased weight capacity, added accessibility, and improved removability with front and rear removal.
  • Page 25: Installation Guidelines

    To prevent loss of input power, ensure the total maximum loads on the circuits supplying power to the switch are within the current ratings for the wiring and breakers. Note For AC input application, please refer to the statement below: Cisco Nexus 9332PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 26: Unpacking And Inspecting The Switch

    Check for damage and report any discrepancies or damage to your customer service representative. Have the following information ready: • Invoice number of shipper (see packing slip) • Model and serial number of the damaged unit • Description of damage Cisco Nexus 9332PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 27: Installing The Switch Using The Nxk-Acc-Kit-1Ru Rack-Mount Kit

    Install two front rack-mount brackets and the two rear rack-mount brackets to the switch as follows: a) Determine which end of the chassis is to be located in the cold aisle as follows: Cisco Nexus 9332PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 28 Grounding the Chassis, on page 25 section. If you are installing the chassis into a grounded rack, you can skip this step. Step 3 Install the slider rails on the rack or cabinet as follows: Cisco Nexus 9332PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 29 Holding the switch with both hands, position the two rear rack-mount brackets on the switch between the rack or cabinet posts that do not have slider rails attached to them (see the following figure). Cisco Nexus 9332PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 30: Installingtheswitchusingthen3K-C3064-Acc-Kitrack-Mount Kit

    You must supply the eight 10-32 or 12-24 screws required to mount the slider rails and switch to the rack. Before you begin • You have inspected the switch shipment to ensure that you have everything ordered. • Make sure that the switch rack-mount kit includes the following parts: Cisco Nexus 9332PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 31 (3 inches [7.6 mm] minimum) and module handles (1 inch [2.5 mm] minimum). Cisco Nexus 9332PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 32 Attach the guide to the chassis using two M4 screws (see Callout 4 or 8 in the previous figure). Tighten the screws to 12 in-lb (1.36 N·m) of torque. c) Repeat Step 2 for the other rear rack-mount bracket on the other side of the switch. Cisco Nexus 9332PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 33 Holding the switch with both hands, position the two rear rack-mount brackets on the switch between the rack or cabinet posts that do not have slider rails attached to them (see the following figure). Cisco Nexus 9332PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 34 Holding the chassis level, insert two screws (12-24 or 10-32, depending on the rack type) in each of the two front rack-mount brackets (using a total of four screws) and into the cage nuts or threaded holes in the vertical rack-mounting rails (see the following figure). Cisco Nexus 9332PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 35: Grounding The Chassis

    This equipment must be grounded. To reduce the risk of electric shock, never defeat the ground conductor or operate the equipment in the absence of a suitably installed ground conductor. Contact the appropriate electrical inspection authority or an electrician if you are uncertain that suitable grounding is available. Cisco Nexus 9332PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 36 Secure the grounding lug to the chassis grounding pad with two M4 screws, see the previous figure. Tighten the screws to 11 to 15 in-lb (1.24 to 1.69 N·m) of torque. Step 4 Prepare the other end of the grounding wire and connect it to the facility ground. Cisco Nexus 9332PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 37: Starting The Switch

    3. Place the power cable negative-wire terminal ring on the negative terminal for the power source and secure them with a terminal nut. 4. Place the power cable positive-wire terminal ring on the positive terminal for the power source and secure them with a terminal nut. Cisco Nexus 9332PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 38 A setup utility automatically launches the first time that you access the switch and guides you through the basic configuration. For instructions on how to configure the switch and check module connectivity, see the appropriate Cisco Nexus 9000 Series configuration guide.
  • Page 39: Connecting The Switch To The Aci Fabric

    Note To prevent sub-optimal forwarding between endpoints, connect every leaf switch in the fabric to every spine switch in the same fabric. Cisco Nexus 9332PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 40: Preparing To Connect To Other Devices

    Cisco equipment. In situations where long parallel cable runs cannot be separated by at least 3.3 feet (1 meter), we recommend that you shield any potential noise sources by housing them in a grounded metallic conduit.
  • Page 41: Connecting Leaf Switches To Apics

    Connecting Leaf Switches to APICs You must downlink one or two (recommended for redundancy) Cisco Nexus 9300 platform ACI-mode leaf switches to each Application Policy Infrastructure Controller (APIC) in your ACI fabric. The type of virtual interface card (VIC) installed on the APIC determines the types of interface cables that you can use to connect the leaf switches to the APICs.
  • Page 42: Connecting Leaf Switches To Spine Switches

    Connect the other end of the interface cable to a downlink port on a leaf switch. • For a Cisco 10GBASE-LR or -SR transceiver and cable, insert the transceiver into a downlink optical port on a leaf switch before connecting the cable to the transceiver.
  • Page 43 • If there are modular switches in the fabric, their ACI-mode line cards must already be installed. The line cards can be of the following types: • 36-port 40-Gigabit (such as: N9K-X9736PQ) • 32-port 100-Gigabit (such as: N9K-X9732C-EX) (supported by Cisco Nexus 9504 and 9508 modular switches) • 36-port 100-Gigabit (such as: N9K-X9736C-FX) Note You cannot include NX-OS line cards in the same chassis when running in ACI mode.
  • Page 44: Installing A Gigabit Ethernet Module (Gem)

    First-generation Cisco Nexus 9000 Series switches include those switches that do not contain an EX or an FX in the PID (product identification). Second-generation Cisco Nexus 9000 Series switches include those switches that have an EX or an FX in the PID.
  • Page 45: Setting Up An Optional Console Interface

    Before you begin The console device must support VT100 terminal emulations and asynchronous transmissions. Step 1 Configure the terminal emulator program to match each of the following default port characteristics: • 9600 baud Cisco Nexus 9332PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 46: Setting Up An Optional Management Connection

    DB-9 connector on the other end of the cable to the serial port on the console device. What to do next You can now perform the initial configuration for the switch (see the Cisco ACI Getting Started Guide). Setting Up an Optional Management Connection You can optionally set up an out-of-band management connection for monitoring and troubleshooting purposes.
  • Page 47: Maintaining Transceivers And Optical Cables

    Transceivers and fiber-optic cables must be kept clean and dust free to maintain high signal accuracy and prevent damage to the connectors. Contamination increases attenuation (loss of light) and should be below 0.35 dB. Cisco Nexus 9332PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 48 • Inspect routinely for dust and damage. If you suspect damage, clean and then inspect fiber ends under a microscope to determine if damage has occurred. Cisco Nexus 9332PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 49: Replacing Components

    On the fan module that you are removing, press the two sides of the fan module handle next to where it connects to the fan module and pull on the handles enough to unseat it from its connectors. Step 2 Holding the handle, pull the module out of the chassis. Cisco Nexus 9332PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 50: Installing A Fan Module

    Before you begin • The replacement power supply must have the same wattage and airflow direction as the power supply being replaced. Do not mix AC, DC, HVAC/HVDC power supplies in the same switch. Cisco Nexus 9332PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 51 Depending on the outlet receptacle on your power distribution unit, you might need the optional jumper cable to connect the switch to your outlet receptacle. e) Verify that the power supply is operational by making sure that the power supply LED is green. Cisco Nexus 9332PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 52: Replacing A Dc Power Supply

    Holding the replacement power supply with one hand underneath the module and the other hand holding the handle, turn the power supply so that its release latch is on the right side and align the back end of the power supply (the end Cisco Nexus 9332PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 53 Attach the power connector block end of the power cable to the electrical outlet on the front of the power supply. d) Turn on the circuit breaker for the power source. e) Verify that the power supply is operational by making sure that the power supply LED is green. Cisco Nexus 9332PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 54 Replacing Components Replacing a DC Power Supply Cisco Nexus 9332PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 55: Rack Specifications

    • Standard 19-inch (48.3 cm) (two- or four-post EIA cabinet or rack, with mounting rails that conform to English universal hole spacing per section 1 of ANSI/EIA-310-D-1992). For more information, see Requirements Specific to Perforated Cabinets, on page Cisco Nexus 9332PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 56: Requirements Specific To Standard Open Racks

    • The roof should be perforated with at least a 20 percent open area. • The cabinet floor should be open or perforated to enhance cooling. The Cisco R Series rack conforms to these requirements. Cable Management Guidelines To help with cable management, you might want to allow additional space in the rack above and below the chassis to make it easier to route all of the fiber optic or copper cables through the rack.
  • Page 57: System Specifications

    Operating 0 to 13,123 feet (0 to 4,000 meters) Switch Dimensions Switch Width Depth Height Cisco Nexus 9332PQ 17.3 inches (43.9 cm) 22.5 inches (57.1 cm) 1.72 inches (4.4 cm) (1 RU) Cisco Nexus 9332PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 58: Switch And Module Weights And Quantities

    Switch Typical Power Maximum Power Heat Dissipation Consumption (AC or DC) Consumption (AC or DC) Requirement Cisco Nexus 9332PQ 228 W 508 W 1733.367 BTUs per hour Cisco Nexus 9332PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 59: Power Specifications

    Maximum AC input current 7.6 A at 90 - 132 VAC 3.65 A at 180 - 264 VAC Maximum input volt-amperes 760 VA at 100 VAC Maximum output power per power supply 650 W Cisco Nexus 9332PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 60: 930-W Dc Power Supply (Port-Side Intake) Specifications

    These specifications apply to the 930-W DC (UCS-PSU-6332-DC) power supplies. Characteristic Specification Maximum DC input current 23 A at -48 VDC Maximum input W 1104 W Maximum output power per power supply 930 W Cisco Nexus 9332PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 61: Power Cable Specifications

    250 V, 10 A, 8.2 feet (2.5 m) Italy CAB-9K10A-IT 250 VAC, 10 A, CEI 23-16/VII plug, 8.2 feet (2.5 m) Japan CAB-C13-C14-2M-JP Power Cord Jumper, C13-C14 Connectors, 6.6 feet (2.0 m) Cisco Nexus 9332PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 62: Hvac/Hvdc Power Cables Supported By Aci-Mode And Nx-Os Mode Switches

    Part Number Cord Set Description Photo CAB-HVAC-SD-0.6M HVAC 2-foot (0.6 m) cable with Saf-D-Grid and SD connectors 277V AC CAB-HVAC-RT-0.6M HVAC 2-foot (0.6 m) cable with Saf-D-Grid and RT connector 277V AC Cisco Nexus 9332PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 63: Dc Power Cable Specifications

    The following table lists the regulatory standards compliance for the switch. Table 2: Regulatory Standards Compliance: Safety and EMC Specification Description Regulatory compliance Products should comply with CE Markings according to directives 2004/108/EC and 2006/95/EC. Cisco Nexus 9332PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 64 • CNS13438 Class A EMC: Immunity • EN55024 • CISPR24 • EN300386 • KN 61000-4 series RoHS The product is RoH-6 compliant with exceptions for leaded-ball grid-array (BGA) balls and lead press-fit connectors. Cisco Nexus 9332PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 65: Leds

    Temperature exceeds the major alarm threshold. The switch is not receiving power. Green Fans and power supply modules are operational. Amber At least one fan or power supply module is not operating. Cisco Nexus 9332PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 66: Lane Link Leds

    Power supply is on and outputting power to the switch. Flashing Power supply is connected to a power source but not outputting power to the green switch—power supply might not be installed in the chassis. Power supply is not receiving power. Cisco Nexus 9332PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 67 Power supply warning—possibly one of the following conditions: • High voltage • High power • Low voltage • Power supply installed in chassis but not connected to a power source • Slow power supply fan Cisco Nexus 9332PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 68 LEDs LEDs Cisco Nexus 9332PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 69: Additional Kits

    • M4 x 8-mm Phillips pan-head screws (2) Not applicable EAC Compliance document Not applicable Hazardous substances list for customers in China The following table lists and illustrates the console cable (CAB-CONSOLE-RJ45) that can be ordered. Cisco Nexus 9332PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 70: Rack Mount Kit N3K-C3064-Acc-Kit

    Not applicable Hazardous substances list for customers in China The following table lists and illustrates the console cable (CAB-CONSOLE-RJ45) that can be ordered. Illustration Description Quantity Console cable with DB-9F and RJ-45F connectors Cisco Nexus 9332PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 71: Site Preparation And Maintenance Records

    Your completion of each task ensures a successful switch installation. Planning Activity Verification Time and Date Space evaluation: Space and layout Floor covering Impact and vibration Lighting Physical access Maintenance access Environmental evaluation: Ambient temperature Humidity Altitude Atmospheric contamination Airflow Cisco Nexus 9332PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 72: Contact And Site Information

    (transceivers) EMI evaluation: Distance limitations for signaling Site wiring RFI levels Contact and Site Information Use the following worksheet to record contact and site information for the installation. Contact person Contact phone Cisco Nexus 9332PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 73 Domain name IP broadcast address Gateway/router address DNS address Use the following worksheet to record information about the modules in the switch. Module Slot Module Type Module Serial Number Notes Fan module 1 Cisco Nexus 9332PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 74 Site Preparation and Maintenance Records Site Preparation and Maintenance Records Module Slot Module Type Module Serial Number Notes Fan module 2 Fan module 3 Fan module 4 Power Supply 1 Power Supply 2 Cisco Nexus 9332PQ ACI-Mode Switch Hardware Installation Guide...

This manual is also suitable for:

Nexus 9332pq

Table of Contents