Pilz PSEN op4F/H-A Series Operating Manual page 79

Safety light curtain
Table of Contents

Advertisement

OPERATING MANUAL
PSEN op4H-A-30-030/1
PSEN op4H-A-30-045/1
PSEN op4H-A-30-060/1
PSEN op4H-A-30-075/1
PSEN op4H-A-30-090/1
PSEN op4H-A-30-105/1
PSEN op4H-A-30-120/1
PSEN op4H-A-30-135/1
PSEN op4H-A-30-150/1
PSEN op4H-A-30-165/1
PSEN op4H-A-30-180/1
1003067-EN-04
Response time of
Response time of
Master AIC OFF
Slave AIC OFF
(ms)
Tmaster
11.9
12.8
13.7
14.5
15.4
16.3
17.2
18.0
18.9
19.8
20.7
Response time of
Master AIC ON
(ms)
(ms)
Tslave
Tmaster AIC
11.9
14.6
12.8
16.8
13.7
19.1
14.5
21.3
15.4
23.6
16.3
25.8
17.2
28.1
-
30.3
-
32.6
-
34.8
-
37.1
PSEN op4F/H-A series
Response time of
Slave AIC ON
(ms)
Tslave AIC
15
17
19
21
24
26
28
-
-
-
-
79