Pilz PSEN op4F/H-A Series Operating Manual page 26

Safety light curtain
Table of Contents

Advertisement

OPERATING MANUAL
12-pin
CONNECTION
RESET
RESTART
ALIGNMENT
OVERRIDE 1
OVERRIDE 2
EDM
MUTING
DEACTIVATION
26
PSENopt Advanced RX Blanking
PSENopt Advanced TX
Assignment of M12 connector
PSENopt Advanced RX Muting
LINE
24Vdc
IN line
N.O.
24Vdc
IN line
N.O.
24Vdc
IN line
N.O.
24Vdc
IN line
N.O.
IN line
N.O.
See section 7.4 for
connections
24Vdc
IN line
N.O.
M12 12-Pin:
1.
24 V (brown)
2.
0 V (blue)
M12 12 pin
3.
RESET/RESTART/ALIGN (white)
4.
TEACH IN (green)
5.
OSSD2 (pink)
6.
EDM (yellow)
7.
NC (black)
8.
OSSD1 (grey)
9.
TOLERANCE (red)
10.
LAMP (purple)
11.
NC (grey-pink)
12.
EARTHING (red-blue)
M12 5-Pin:
1.
24 V (brown)
2.
M12 5 pin
TEST (white)
3.
0 V (blue)
4.
EARTH (black)
5.
REDUCED RANGE (grey)
BEHAVIOUR
Is connected – when in disabled state the
RESET/RESTART/ALIGN button is operated
Is connected – when during operation the
RESET/RESTART/ALIGN button is operated
Has to be set to 24 V DC at startup
Is connected – when Override is active during
operation
No voltage – during operation
Must be non-equivalent to OSSD during operation
with EDM enabled
Muting is disabled when connecting
PSEN op4F/H-A series
5-pin
1003067-EN-04

Advertisement

Table of Contents
loading

Table of Contents