7.5 EDM selection

This function enables users to select or exclude monitoring of the external switching devices.
Activated
Deactivated
To increase the safety level when EDM is OFF when the light curtain is commissioned,
ensure that the EDM input is not connected.

7.6 Reduced range

This function enables you to select the maximum operating range for the light curtain's
assembly.
The table below summarises the different operating ranges for both resolutions, if the
reduced operating range is changed.
Resolution 30 mm
TX long range
TX short range
Resolution 14 mm
TX long range
TX short range
You can select this function via ACM for the receiver and via BCM for the transmitter.
1003067-EN-04
BCM configuration: EDM selection
LED 4 ON yellow
LED 4 OFF
ACM configuration: EDM selection
RX long range
20 m
12 m
RX long range
7 m
4 m
Fig. 39 – Reduced range
PSEN op4F/H-A series
RX short range
6 m
4 m
RX short range
2 m
1 m
LEVEL
43