Pilz PSEN op4F/H-A Series Operating Manual page 24

Safety light curtain
Table of Contents

Advertisement

OPERATING MANUAL
The mounting positions recommended based on the length of the light curtain are stated in
Fig. 19 and in the following table.
MODEL
PSEN op4F-A-14-030/1
PSEN op4H-A-30-030/1
PSEN op4F-A-14-045/1
PSEN op4H-A-30-045/1
PSEN op4F-A-14-060/1
PSEN op4H-A-30-060/1
PSEN op4F-A-14-075/1
PSEN op4H-A-30-075/1
PSEN op4F-A-14-090/1
PSEN op4H-A-30-090/1
PSEN op4F-A-14-105/1
PSEN op4H-A-30-105/1
PSEN op4F-A-14-120/1
PSEN op4H-A-30-120/1
PSEN op4F-A-14-135/1
PSEN op4H-A-30-135/1
PSEN op4F-A-14-150/1
PSEN op4H-A-30-150/1
PSEN op4F-A-14-165/1
PSEN op4H-A-30-165/1
PSEN op4F-A-14-180/1
PSEN op4H-A-30-180/1
24
Fig. 19 – Light curtain dimensions
L (mm)
L (mm)
incl. PSEN op
advanced
programming
adapter
363.2
306.3
513.2
456.3
663.1
606.2
813.1
756.2
963.0
906.1
1113.0
1056.1
1262.9
1206
1412.9
1356
1562.8
1505.9
1712.8
1655.9
1862.7
1805.8
PSEN op4F/H-A series
A (mm)
B (mm) C (mm)
86.3
110
236.3
110
306.2
150
406.2
175
506.1
200
606.1
225
966
150
1066
175
1166
200
1266
225
1366
250
652.9
1003067-EN-04
-
-
-
-
-
-
453
503
553
603

Advertisement

Table of Contents
loading

Table of Contents