7.9.8

Blanking mode in advanced configuration

A maximum of 5 blanking zones (fixed + floating) can be configured in ACM (however, at
least one separating beam is required between the zones).
The user can select the number of beams via ACM.
• Reduced resolution
The software calculates the maximum object size (in mm) that the light curtain can detect
without triggering a SAFE STATE.
The actual resolution of the light curtain changes based on the varying value that is
assigned to the parameter N.
The safety distance must be calculated based on the actual resolution.
Number of
hidden light
beams
1
2
3
4
1003067-EN-04
ACM configuration
Actual resolution of light curtain
14 mm
23 mm
33 mm
42 mm
51 mm
Actual resolution based on the hidden light beams
30 mm
49 mm
68 mm
87 mm
105 mm