Installation of the Cabinet
Step 1
Remove the air conditioner from the package, remove fixing
screws and slide the air conditioner out from the cabinet (Refer
to Installation Steps).
Step 2
Drill holes in the wall to ensure the cabinet can be well
supported. Holes from the outside through to the cavity should be
sealed. The cabinet should slope down towards the rear by
about 10mm to allow water drainage during operation.
Step 3
Install and secure the cabinet into the wall. Ensure the foam
seals are not damaged. Flash, seal or fill gaps around the
inside and outside to provide satisfactory appearance and
protection against the weather, insects and rodents.
Installation of the unit into the Cabinet
1. Slide the unit into the cabinet until it is firmly against the
rear of the cabinet. Ensure the foam
sealing strips on the cabinet remain in position.
2. Connect the air conditioner to the power and put
excess cord on the air conditioner base.
3. Engage the chassis fixing brackets into the bottom cabinet
rail and secure to the base with the screw provided.
4. Remove the front panel from the carton and plastic bag
and fit as per the Installation lnstruction.
5. Switch unit on to check for operation of the unit and
vibration in the installation.
6. Fit the drain pan to the cabinet and run a drain tube to a
suitable location if required.
Installation of the unit into the wall
The minmum gap between the wall and the cabinet or air inlet louvers:
Less than C
more than D
Wall thickness is less than C
Make rear side lower so that water will drain
out smoothly.
Scrape
If the wall thickness is more than
C
scrape the wall as shown above.
More than A
More than A
More than B
11
NOTE: UNIT CAN BE SUPPORTED BY A
SOLID FRAME FROM BELOW OR
BY A HANGER FROM A SOLID
OVERHEAD SUPPORT.
FLASH OR SEAL AROUND EXTERNAL
WALL FRAME OR ARCHITRAVE
STURDY TIMBER
FRAME ALL ROUND
UNIT
TIMBER FRAMED
WALL OR PARTITION
Preferred method of installation into a timber
framed wall, partition or window.
FLASH OR SEAL AROUND EXTERNAL
WALL FRAME OR ARCHITRAVE
STURDY TIMBER
FRAME
TIMBER FRAMED
WALL OR PARTITION
SOLID TIMBER SUPPORT
Alternative method of installation if external
support cannot be provided.
A
B
C
D
Position A is determined by
the specific model and
environment, however,
Less than
C
the installation distance
must not be less than 200 mm.
DRAIN TRAY
EXTERNAL SUPPORT
FRAME AT BALANCE
POINT OF A/C
ALTERNATIVELY, BRACKETS
AS ILLUSTRATED BELOW
MAY BE USED.
ENSURE LOUVRES
ARE ENTIRELY
OUTSIDE THE WALL
DRAIN TRAY
STEADYING BRACKET
(ONE PER SIDE)
Size(mm)
200*
500
210
60