Installations:
For the DTP pumps in basic versions several installation options are possible.
These options will be explained, with focus on specific points of attention.
Installation "BWK"
This installation represents a permanent submerged installation using the header coupling" type
"BWK".
The pumps are suspended in horizontal position to the coupling.
Points of attention:
Ensure a good free passage under the pump, at least identical
to the suction opening.
Adjust start- and stop levels in such a way that the motor
will not make more than 20 starts per hour.
Check that the motor is adequately cooled.
At full load conditions, at least 2/3 of the motor housing should
be submerged.
The pump casing must stay under water to avoid air being
drawn in.
Installation "OWK"
This installation represents a permanent submerged installation using the guide bar coupling"
type "OWK050"
Points of attention:
Ensure a good free passage under the pump, at least identical
to the suction opening.
Check both the vertical and parallel position of the guide bars.
The maximum tolerance for the vertical position is ± 3
The installation angle for the pump in case of installation or
taking out is important.
This angle (between pump and guide bar) is about 0
This angle can be adjusted by changing the position of the
hoisting cable.
Adjust start- and stop levels in such a way that the motor will
not make more than 20 starts per hour.
Check that the motor is adequately cooled.
At full load conditions, at least 2/3 of the motor housing should be submerged.
The pump casing must stay under water to avoid air being drawn in.
Landustrie versie 01-21 | Operation & maintenance manual DCP22