5.5.4.2

Connecting the power cord (AC PSU)

CAUTION
The AC PSU adjusts automatically to any mains voltage in the range
from 100 V - 240 V (AC PSU Platinum) or 200 V - 240 V (AC PSU
Titanium).
You may only operate the server if its rated voltage range
corresponds to the local mains voltage.
▶ Connect the power cord to the PSU.
▶ If applicable, connect the main plug to an power outlet of the rack socket
strip.
To provide true phase redundancy, the second PSU should be
connected to a different AC power source from the other PSU. If one
AC power source should fail, the server will still continue to run.
▶ Ensure that the status indicator on the PSU is lit green, see
hot-plug PSU" on page
You can secure the power cord with a cable clamp to ensure that the
power cord cannot be disconnected from the server by mistake.