Room air quality sensor and measuring trancuder

Advertisement

Available languages

Available languages

  • ENGLISH, page 6

Quick Links

D G F r
6000-3760-0000-1XX 37600-2021 V107 05 ⁄ 2021
RLQ - W
® 
AERASGARD
RLQ - SD
AERASGARD
® 
D
Bedienungs- und Montageanleitung
Raum-Luftqualitätsfühler (VOC) bzw. Messumformer,
selbstkalibrierend, mit Mehrbereichsumschaltung
und aktivem ⁄ schaltendem Ausgang
G
Operating Instructions, Mounting & Installation
Room air quality sensor (VOC) and measuring transducer,
self-calibrating, with multi-range switching
and active ⁄ switching output
F
Notice d'instruction
Sonde d'ambiance de qualité de l'air (COV) resp. convertisseur
de mesure, auto-calibrant, avec commutation multi-gamme
et sortie active ⁄ tout ou rien
r
Руководство по монтажу и обслуживанию
Датчик ⁄ измерительный преобразователь качества воздуха
(VOC) для помещений, самокалибрующийся,
с переключением между несколькими диапазонами
и активным ⁄ релейным выходом
S+S REGELTECHNIK GMBH
THURN-UND-TAXIS - STR. 22
90411 NÜRNBERG ⁄ GERMANY
FON +49 ( 0 ) 911 ⁄ 5 19 47- 0
mail@SplusS.de
www.SplusS.de
RLQ - W
RLQ - SD
RLQ - W - A
RLQ - W VA
CARTONS
ET EMBALLAGE
PAPIER À TRIER

Advertisement

loading

Summary of Contents for S+S Regeltechnik AERASGARD RLQ-W

  • Page 1 с переключением между несколькими диапазонами и активным ⁄ релейным выходом RLQ - W - A RLQ - W VA S+S REGELTECHNIK GMBH THURN-UND-TAXIS - STR. 22 90411 NÜRNBERG ⁄ GERMANY CARTONS FON +49 ( 0 ) 911 ⁄ 5 19 47- 0 ET EMBALLAGE mail@SplusS.de...
  • Page 2 D G F r RLQ - W ®  AERASGARD RLQ - SD AERASGARD ®  Gehäuse Baldur 1 Maßzeichnung Housing Baldur 1 Dimensional drawing Plan coté boîtier Baldur 1 Габаритный чертеж Корпус Baldur 1 27.2 Maßzeichnung Gehäuse Edelstahl Dimensional drawing Housing stainless steel Plan coté...
  • Page 3 ® AERASGARD RLQ - W ⁄ RLQ - SD Rev. 2021 - V36 Wartungsfreier Raumfühler AERASGARD ® RLQ - SD mit aktivem Ausgang, automatischer Kalibrierung, im formschönen Kunststoffgehäuse mit Schnapp deckel, zur Ermittlung der Luftqualität bzw. Luftgüte (0…100 % VOC). Der Messumformer wandelt die Messgrößen in ein Normsignal von 0 -10 V. Wartungsfreier Raumfühler AERASGARD ®...
  • Page 4 Montage und Inbetriebnahme Rev. 2021 - V36 ACHTUNG !  DIP-Schalter RLQ - SD Der Gas austausch im Sensorelement erfolgt durch Diffusion. Je nach Konzen- VOC - Sensibilität DIP 1 DIP 2 trationsänderung und Strömungs geschwindigkeit der Luft in Sensor umgebung kann die Reaktion des Gerätes auf die Konzentrations änderung verzögert MEDIUM (default) auftreten.
  • Page 5 Wichtige Hinweise – Dieses Gerät darf nur in nicht kondensierender Luft ohne Über- oder Unterdruck am Sensorelement eingesetzt werden. – Der Spannungsausgang ist kurzschlussfest. – Dass Anlegen einer Überspannung zerstört das Gerät. – Bei Verunreinigungen empfehlen wir eine werksseitige Reinigung und Neukalibrierung. –...
  • Page 6 ® AERASGARD RLQ - W ⁄ RLQ - SD Rev. 2021 - V36 Maintenance-free room sensor AERASGARD ® RLQ - SD with active output, automatic calibration, in an elegant plastic housing with snap-on lid, for determining the air quality (0…100 % VOC). The measuring transducer converts the measured values into a standard signal of 0 -10 V or 4...20 mA (switchable).
  • Page 7 Installation and Commissioning Rev. 2021 - V36 ATTENTION !  DIP switches RLQ - SD The gas inter-exchange in the sensor element happens by diffusion. Depending VOC sensitivity DIP 1 DIP 2 on the changes to the concentration and the flow velocity of the air surrounding the sensor, the reaction of the device to the change of concentration may take MEDIUM (default) place with a delay.
  • Page 8 General notes – This device may only be used in non-precipitating air without above-atmospheric or below-atmospheric pressure at the sensor element. – The voltage output is short-circuit proof. – Applying overvoltage will destroy the device. – In case of pollution, we recommend cleaning and recalibration in the factory. –...
  • Page 9 ® AERASGARD RLQ - W ⁄ RLQ - SD Rev. 2021 - V36 Sonde d’ambiance AERASGARD ® RLQ - SD sans entretien avec sortie active, calibrage automatique, dans un boîtier plastique élégant avec couvercle emboîté, pour déterminer la qualité de l’air (0…100 % VOC). Le convertisseur de mesure convertit les grandeurs de mesure en un signal normalisé de 0 -10 V. ®...
  • Page 10 Montage et mise en service Rev. 2021 - V36 ATTENTION !   Interrupteur DIP RLQ - SD L'échange de gazdans l'élément capteur s'effectue par diffusion. En fonction de la Sensibilité COV DIP 1 DIP 2 variation de la concentration et de la vitesse d'écoulement de l'air dans l'environ- nement du capteur, la réaction de l'appareil à...
  • Page 11 Généralités – Cet appareil ne doit être utilisé que dans un air sans risque de condensation, sans risque de surpression ou dépression sur l’élément sensible. – La sortie en tension est isolée de la masse. – L’application d’une surtension causera la destruction de l’appareil. –...
  • Page 12 ® AERASGARD RLQ - W ⁄ RLQ - SD Rev. 2021 - V36 Не нуждающийся в техническом обслуживании датчик для помещений AERASGARD ® RLQ - SD с активным выходом, автоматической калибровкой в элегантном пластиковом корпусе с защелкивающейся крышкой. Служит для измерения качества и чистоты воздуха (0…100 % VOC). Измерительный преобразователь...
  • Page 13 Монтаж и ввод в эксплуатацию Rev. 2021 - V36 ВНИМАНИЕ !  DIP-переключатели RLQ - SD Газообмен в чувствительном элементе осуществляется благодаря диффузии. В Чувствительность VOC DIP 1 DIP 2 зависимости от изменения концентрации и скорости потока воздуха вблизи чувствительного элемента реакция прибора на изменение концентрации может происходить...
  • Page 14 Указания к продуктам – Данный прибор допускается применять только в воздухе без конденсата и вредных веществ, при отсутствии пониженного или повышенного давления вблизи чувствительного элемента. – Выход напряжения защищен от короткого замыкания. – Приложение завышенного напряжения к выходу напряжения выводит прибор из строя. –...
  • Page 15 Reprint in full or in parts requires permission from S+S Regeltechnik GmbH. La reproduction des textes même partielle est uniquement autorisée après accord de la société S+S Regeltechnik GmbH. Перепечатка, в том числе в сокращенном виде, разрешается лишь с согласия S+S Regeltechnik GmbH.
  • Page 16 D G F r RLQ - W ®  AERASGARD RLQ - SD AERASGARD ®  RLQ - W RLQ - W Schaltbild Connecting diagram Schéma de raccordement Схема подключения +UB 24V AC/DC +UB 24V AC/DC ON DIP ON DIP Output air quality Ausgang Luftgüte 1 2 3 4 5 1 2 3 4 5...