Available languages

8. After charging, power-off the charger
and disconnect from the mains' power
supply. The minus and plus terminals
can then be disconnected.
9. This charger includes high-strength
magnets and should not be placed in
close proximity to magnetic storage
devices such as computer hard drives
and tape media.
Charging phase details
Provide chargers for a variance of vehicles and
equipment such as motorbikes, snowmobiles,
lawnmowers and boats etc.
Battery Type
Lead acid battery (open and closed types),
AGM and Gel batteries included.
Pre Analysis
The charger checks if the battery is correctly
connected. The battery's charge level (V) and
total capacity (Ah) is measured to determine the
correct settings for charging.
Battery
voltage
>12.65V
12.55V–12.65V
12.45V–12.55V
12.35V–12.45V
2.0V–12.35V
Battery
status
95–100%
80%
60%
40%
0-20%
LED
indication
All segments on
4 segments on
3 segments on
2 segments on
1 segment on