Viking FPNI515 Installation Manual

Viking FPNI515 Installation Manual

15”w. undercounter/freestanding nugget ice machine
Hide thumbs Also See for FPNI515:

Advertisement

Quick Links

Viking Range, LLC
111 Front Street
Greenwood, Mississippi 38930 USA (662) 455-1200
For product information,
call 1-888-(845-4641)
or visit our web site at vikingrange.com in the US
or brigade.ca in Canada
U L
U L
C
F21312 EN
17-3479-02
(091513)
Installation Guide
15"W. Undercounter/Freestanding
Nugget Ice Machine

Advertisement

Table of Contents
loading

Summary of Contents for Viking FPNI515

  • Page 1 Installation Guide Viking Range, LLC 111 Front Street Greenwood, Mississippi 38930 USA (662) 455-1200 For product information, call 1-888-(845-4641) or visit our web site at vikingrange.com in the US or brigade.ca in Canada 15”W. Undercounter/Freestanding Nugget Ice Machine F21312 EN...
  • Page 2: Table Of Contents

    Filters and Treatment _______________________________________________________________________________________9 water or moisture. Installation Overview_______________________________________________________________________________________10 • Viking Range, LLC will NOT warranty any problems resulting from GFI outlets which are not installed properly or do not Accessory Door Panel ______________________________________________________________________________________10 meet the requirements below. Custom Panel _____________________________________________________________________________________________10...
  • Page 3: Dimensions (Custom Panel)

    Important - Please read and Follow! Dimensions PROPER DISPOSAL (OF OLD REFRIGERATION UNIT) FGNI/FPNI w/ Professional door panel DANGER - 7 / - 7 / - 7 / ( 3 7 ( 3 7 ( 3 7 8 ” 8 ” 8 ”...
  • Page 4: Specifications

    Specifications 15”W. Undercounter/Freestanding Ice Machine FGNI/FPNI w/ Custom door panel - 7 / - 7 / - 7 / Description FGNI515 FPNI515 ( 3 7 ( 3 7 ( 3 7 8 ” 8 ” 8 ” Overall width 14-7/8” (37.8 cm) Overall height 33-7/8”...
  • Page 5: Drain/Electrical Locations

    Drain / Electrical Location Installation INSTALLATION OVERVIEW 2-3/4” The ice machine must: 1/4” (0.6 cm) (7.0 cm) • Be connected to cold, potable water. O.D. Copper Water • Be connected to a drain. Inlet Compression • Be connected to the proper power supply. Fitting Provided •...
  • Page 6: Custom Panel

    Installation (con’t) Installation (con’t) CUSTOM PANEL 13-9/16” CUSTOM PANEL DIMENSIONS (34.4 cm) 6-25/32” A custom panel of wood or other material not exceeding 15 lb can be attached to the door. Attachment is from the ice (17.7 cm) side of the door. Holes are provided in the door for this purpose. 8-1/4”...
  • Page 7: Door Panel Attachment

    Installation (con’t) Installation (con’t) DOOR SWING CHANGE DOOR PANEL ATTACHMENT The door can be attached to open with hinges on the left or right using new brackets shipped loose in the ice bin. Retain all screws for re-use. Inner screw Outer screw To change: Use Upper...
  • Page 8: Water And Drain Installation

    Installation (con’t) Installation (con’t) WATER & DRAIN INSTALLATION GRAVITY DRAIN PUMP MODEL DRAIN INSTALLATION The recommended water supply tubing is 1/4” OD copper. Stainless steel flex or reinforced PVC tube may also be CAUTION used. Install an easily accessible shut-off valve between the supply and the unit. This shut-off valve should not be installed behind the unit.
  • Page 9: Electrical Connection

    Clearly describe the problem that you are having. If you are unable to obtain the name of an authorized service agency, or if you continue to have service problems, contact Viking Range, LLC at 1-888-(845-4641), or write to: FINAL INSTALLATION 1.

This manual is also suitable for:

Fgni515

Table of Contents