• The required use of a GFI is normally related to the location of a receptacle with respect to any significant sources of water or moisture. • Viking Range Corporation will NOT warranty any problems resulting from GFI outlets which are not installed properly or do not meet the requirements below.
Page 4
PROPER DISPOSAL (OF OLD REFRIGERATION UNIT) DANGER RISK OF CHILD ENTRAPMENT Before You Throw Away Your Old Refrigeration Unit: • Take off the doors. • Leave the shelves in place so that children may not easily climb inside. IMPORTANT: Child entrapment and suffocation are not problems of the past.
GENERAL INFORMATION AIR FLOW The machine takes in room temperature air at the lower right front and forces warm air out the lower left front. Restricting the airflow will adversely affect the ability of the ice machine to make ice. Filters and Treatment Warm In general, it is always a good idea to filter the water.
INSTALLATION OVERVIEW The ice machine must: • Be connected to cold, potable water. • Be connected to a drain. • Be connected to the proper power supply. • Be able circulate air through the vents at the front. Note: DO NOT build in so that the door is recessed. Door is meant to be flush with surronding cabinetry, but not recessed.
Page 11
4. Subtract 1/8” or more for clearance space between top of door and bottom of countertop edge from cabinet opening. This is the maximum door length. 5. Cut panel to width 6. Cut panel to length (cabinet space - kickplate space - top clearance = length). 7.
DOOR SWING CHANGE The door can be attached to open with hinges on the left or right using new brackets shipped loose in the ice bin. Retain all screws for re-use. To change: 1. Remove inner screw holding each hinge to cabinet, loosen the outer screw. Inner screw 2.
WATER & DRAIN INSTALLATION The recommended water supply tubing is 1/4” OD copper. Stainless steel flex or reinforced PVC tube may also be used. Install an easily accessible shut-off valve between the supply and the unit. This shut-off valve should not be installed behind the unit.
Page 15
Gravity Drain Pump Model drain installation CAUTION Restrictions in the drain system to the machine will cause water to back up into the ice storage bin and melt the ice. Gravity drain tubing must be vented, have no kinks and slope to the building drain. Air gaps are typically required by local code. 1.
ELECTRICAL CONNECTION WARNING ELECTRICAL SHOCK HAZARD Failure to follow these instructions could result in fire or electrical shock. The ice machine is supplied with a power cord. DO NOT remove the grounding pin from the cord’s plug. DO NOT use extension cords. Follow all Grounding type codes.
Clearly describe the problem that you are having. If you are unable to obtain the name of an authorized service agency, or if you continue to have service problems, contact Viking Range Corporation at 1-888- (845-4641), or write to: VIKING RANGE, LLC...
Page 20
Viking Range, LLC 111 Front Street Greenwood, Mississippi 38930 USA (662) 455-1200 For product information, call 1-888-(845-4641) or visit our web site at vikingrange.com in the US or brigade.ca in Canada F20734B EN (061112) 17-3336-01...