Specifications - jbc DDVE-2B Instruction Manual

Premium rework station with pneumatic pump
Table of Contents

Advertisement

Specifications

Premium Rework Station with Pneumatic Pump
DDVE-1B / DDVE-2B / DDVE-9B
- Total weight:
DDE-1B 120V 50/60Hz. Input fuse: 4A. Output: 23.5V
DDE-2B 230V 50/60Hz. Input fuse: 2A. Output: 23.5V
DDE-9B 100V 50/60Hz. Input fuse: 5A. Output: 23.5V
- Net Weight:
- Dimensions:
- Output Peak Power:
- Temperature Range:
- Idle Temp. Stability (still air):
- Tip to ground resistance:
- Tip to ground voltage:
- Ambient Operating Temperature: 10 - 40 ºC (50 - 104 ºF)
- Communicatio connectors:
- Robot connector:
MVE-A
- Net Weight:
- Dimensions:
- Air Pressure supply range:
- Vacuum at 6 Bar:
- Flow rate:
- Ambient operating temp.:
- Pedal connection
Complies with CE standards.
ESD protected.
10
8.35 kg (18.4 lb)
3,815 kg (8.41 lb)
148 x 120 x 232 mm (5.83 x 4.72 x 9.13 in)
150W per tool
90 - 450 °C (190 - 840 ºF)
±1.5 ºC (±3 ºF)
<2 ohms
<2mV RMS
USB-A / USB-B / Peripherals connectors
RJ12 for RS-232 protocol
0.7 kg (1.54 lb)
145 x 55 x 225 mm (5.71 x 2.17 x 8.86 in)
4-6 Bar
90% / 680 mmHg / 26.8 inHg
15 SLPM
10 - 40 ºC (50 - 104 ºF)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ddve-1bDdve-9bDdve-bDde-1bDde-2bDde-9b

Table of Contents